TL881/TL891 Family MiniLibrary System Reference Guide Second Edition (July 2000) Part Number 127510-002 Compaq Computer Corporation Compaq Confidential – Need to Know Required Writer: Bob Young Project: Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Comments: Part Number: 127510-002 File Name: a-frnt.
Notice © 2000 Compaq Computer Corporation. Compaq, the Compaq logo, and StorageWorks Registered in U. S. Patent and Trademark Office. All other product names mentioned herein may be trademarks or registered trademarks of their respective companies. Confidential computer software. Valid license from Compaq required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.
Contents About This Guide Text Conventions..................................................................................................... xiii Symbols in Text........................................................................................................xiv Symbols on Equipment.............................................................................................xiv Rack Stability ...........................................................................................................
iv Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Bar Code Reader............................................................................................. 1-14 Advanced Design Features..................................................................................... 1-14 Embedded Diagnostics ................................................................................... 1-14 Error Checking................................................................................
About This Guide Inserting and Removing Cartridges ....................................................................... 2-28 Removing a Magazine.................................................................................... 2-30 Emergency Magazine Removal...................................................................... 2-30 Inserting Cartridges into the Magazine........................................................... 2-31 Inserting a Magazine ................................................
vi Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Chapter 3 Installation Introduction.............................................................................................................. 3-1 Installation Overview............................................................................................... 3-1 Planning Your Installation ....................................................................................... 3-2 Positioning the Modules ...................
About This Guide Chapter 4 Configuration Configuration Overview .......................................................................................... 4-1 Customizing Your Configuration ............................................................................ 4-2 Descriptions of Configuration Options.................................................................... 4-4 Set Data Format................................................................................................ 4-4 Set SCSI .....
viii Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Appendix A Specifications Introduction............................................................................................................. A-1 Safety ...................................................................................................................... A-6 Electromagnetic Emission (EM) ............................................................................. A-7 Notice...............................
About This Guide Appendix F Tape Drives and Cartridges Introduction ............................................................................................................. F-1 Care and Handling of Cartridges ............................................................................. F-2 Handling and Storage Guidelines ..................................................................... F-2 Checking a Cartridge for Damage ....................................................................
x Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Figure 2-17. Data unit rear view ........................................................................... 2-47 Figure 3-1. PTM external parts ............................................................................... 3-4 Figure 3-2. PTM car (front view)............................................................................ 3-5 Figure 3-3. Car rear view showing belt block................................................
About This Guide List of Tables Table 1-1 Expansion Unit Front View..................................................................... 1-3 Table 1-2 MiniLibrary Base Module Front View.................................................... 1-5 Table 1-3 Data Unit Front View .............................................................................. 1-6 Table 1-4 MiniLibrary Base Module 10-Cartridge Magazine ................................. 1-9 Table 1-5 Expansion Unit Rear View...........................
xii Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 6-3 SCSI Error Codes (1xxx)......................................................................... 6-6 Table 6-4 Control Error Codes (2xxx) ..................................................................... 6-7 Table 6-5 Motor Process Error Codes (3xxx) ........................................................ 6-10 Table 6-6 Power-On Error Codes (4xxx)...............................................................
About This Guide This guide is designed to be used as step-by-step instructions for installation and as a reference for operation, troubleshooting, and future upgrades. Text Conventions This document uses the following conventions to distinguish elements of text: Keys Keys appear in boldface. A plus sign (+) between two keys indicates that they should be pressed simultaneously. USER INPUT User input appears in a different typeface and in uppercase. FILENAMES File names appear in uppercase italics.
xiv Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Symbols in Text These symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life. CAUTION: Text set off in this manner indicates that failure to follow directions could result in damage to equipment or loss of information.
About This Guide Any surface or area of the equipment marked with these symbols indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching. Power Supplies or Systems marked with these symbols indicate the equipment is supplied by multiple sources of power.
xvi Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Getting Help If you have a problem and have exhausted the information in this guide, you can get further information and other help in the following locations. Compaq Technical Support You are entitled to free hardware technical telephone support for your product for as long you own the product. A technical support specialist will help you diagnose the problem or guide you to the next step in the warranty process.
About This Guide Compaq Website The Compaq website has information on this product as well as the latest drivers and Flash ROM images. You can access the Compaq website at http://www.compaq.com. Compaq Authorized Reseller For the name of your nearest Compaq Authorized Reseller: ■ In the United States, call 1-800-345-1518. ■ In Canada, call 1-800-263-5868. ■ Elsewhere, see the Compaq website for locations and telephone numbers.
Chapter 1 System Description Introduction This chapter describes the features of the Expansion Unit, the Base Module, and the Data Unit of the Compaq StorageWorks TL881/TL891 Family TM MiniLibrary System , including storage architecture, SCSI interface, bus performance, and physical configuration/expansion options. The MiniLibrary system is an expandable, modular tape library system that combines DLT technology drives with advanced robotics.
1-2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide In a MiniLibrary system, you can combine modules to provide the right combination of capacity and performance to meet your present storage requirements. The Compaq MiniLibrary storage architecture lets you add modules to optimize throughput and capacity as your needs change. NOTE: There is a specific Low Voltage Differential (LVD) version of the Expansion Unit for the TL891DLX.
System Description Expansion Unit The Expansion Unit (Figure 1-1) integrates the robotics in the individual modules into a single, coordinated library robotics system. The Expansion Unit performs and maintains an inventory of all media present in the system, including bar code data. All necessary system control operations can be performed from the control panel of the Expansion Unit, as well as from the host via software.
1-4 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide In addition to its system control functions, the Expansion Unit has a 16-cartridge magazine with a random access robotic mechanism. The module robotics moves cartridges between the PTM and any of the 16 cartridge storage locations. You can designate a magazine in one of the MiniLibrary Base Modules as a mail slot for inserting or removing one or more single cartridges, which implements the SCSI IMPORT/EXPORT commands.
System Description 1 2 3 Use Cleane r 4 Drive Fault Loader Fault 5 6 SHR-1678 Figure 1-2.
1-6 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Data Unit The Data Unit (Figure 1-3) has a 16-cartridge magazine and a random access robotic mechanism, but no tape drives. The module robotics, under control of the Expansion Unit, moves cartridges between the PTM and any of the 16 cartridge storage locations. 1 2 3 4 5 6 SHR-1677 Figure 1-3.
System Description SCSI Interface Configurations DLT drives in TL891 MiniLibraries use either a fast-wide High Voltage Differential (HVD) or a fast-wide, single-ended SCSI interface. The choice must be made at the time of purchase. DLT drives in a TL891 MiniLibrary system use a fast-wide HVD SCSI interface. DLT drives in a TL891DLX MiniLibrary use a fast-wide auto-sensing Low Voltage Differential (LVD)/single-ended SCSI interface.
1-8 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Physical Configuration The Expansion Unit must be mounted at the top of the stack, which places its control panel at a convenient height. The control panels of the MiniLibrary Base Modules and Data Units are of secondary importance, as they serve mainly to help localize system failures. When installed, the motor drive assembly of the PTM is directly behind the Expansion Unit.
System Description 1 4 3 2 SHR-1680 Figure 1-4. MiniLibrary base module 10-cartridge magazine Table 1-4 MiniLibrary Base Module 10-Cartridge Magazine Figure Legend Description 1 Slot 0 2 Front label slide slot 3 Bar code label slide slot (not used) 4 Slot 9 Compaq Confidential – Need to Know Required Writer: Bob Young Project: Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Comments: Part Number: 127510-002 File Name: b-ch1 System Description.
1-10 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 1 5 4 3 2 SHR-1681 Figure 1-5.
System Description 1 4 2 3 SHR-1682 Figure 1-6. MiniLibrary base module rear view Table 1-6 MiniLibrary Base Module Rear View Figure Legend Description 1 SCSI bus interface: MiniLibrary* (left two connectors) Drive 0 (middle two connectors) Drive 1 (right two connectors) 2 Expansion Unit serial interface connector 3 Power connector 4 Fan * Not used in slave mode.
1-12 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 1 2 1 SHR-1683 Figure 1-7. Data unit rear view Table 1-7 Data Unit Rear View Figure Legend Description 1 Power connector 2 Diagnostics connector Control Panel The control panels for all modules are the same, except for the number of LED indicators. The control panel features a 4-line by 20-character, backlit LCD display, three or four LED indicators, and four buttons.
System Description Display The backlit, 4-line by 20-character control panel display provides a highly intelligible presentation of drive and loader status, menu choices, and error messages. The scrolling feature greatly expands the amount of information available to you. In the Expansion Unit, status information is available for the entire system. The MiniLibrary Base Modules display other information as needed for localizing malfunctions.
1-14 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Integral Fan Cooling A single forced-air fan is mounted inside each module to provide optimum cooling for critical parts, and to prevent the drive and robotics electronics, motors and power supply from overheating.
System Description Error Checking Drives used in the MiniLibrary system apply a 16-bit parity check to each record, a 64-bit CRC to each 4 KB of data, and Reed-Solomon error correction code overall. There is also an internal parity check on the data buffer. Compression MiniLibrary system drives use the standard Digital Lempel-Ziv (DLZ) data compression algorithm. Capacity A single Base Module with its 10-cartridge magazine offers formatted capacities as listed in Table 1-8.
1-16 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 1-8 Base Module Tape Capacities Model Cartridge Magazine Capacity Full Magazine 1 Uncompressed Full Magazine 2 Compressed TL881 DLTtape IV 10 200 GB 400 GB TL891DLX DLTtape IV 10 400 GB 800 GB TL891 DLTtape IV 10 350 GB 700 GB 1 Native capacities, uncompressed. 2 Maximum capacities given assume average 2:1 compression. Actual compression varies with file content.
Chapter 2 Operation Introduction This chapter describes manual operation of the MiniLibrary system. The system is operated manually through the MiniLibrary Expansion Unit control panel. Online and offline operations can be done through the control panels of the MiniLibrary Base Module and the MiniLibrary Data Unit.
2-2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Expansion Unit Figure 2-1 shows the front panel of the Expansion Unit (Table 2-1). The panel includes a power switch and the control panel, which has pushbuttons, LED indicators, and a display. 1 2 3 4 5 6 SHR-1677 Figure 2-1.
Operation 2-3 Power Switch The power switch controls the supply of AC power to the unit. The switch is recessed into the front panel to prevent accidental power-up or power-down. Press 1 to turn the unit on and press 0 to turn the unit off. NOTE: The Expansion Unit must be turned on after or simultaneously with the other modules. If this is not done, the Expansion Unit can not be notified of the presence of one or more of the other modules.
2-4 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Read y Alert Fault Esca pe Ente r SHR-1685 Figure 2-2. Expansion unit control panel Pushbuttons There are four buttons on the control panel, labeled Escape, Enter, , and . The buttons do not directly control specific functions or options.
Operation 2-5 NOTE: When you enter Menu Mode at the Expansion Unit, the Ready light on that module goes out. This means that the MiniLibrary system is off-line, and the system responds to all commands from the host with a SCSI Not Ready until you exit Menu Mode and the Ready light goes on. When you enter Menu Mode at any of the MiniLibrary Base Modules, the Ready light on that module goes out.
2-6 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide NOTE 2: This button is sampled during power-up while all control panel LEDs are on. If it is pressed during that time, the system updates its geometry; that is, it checks for the presence and location of all modules and remaps all media. Use this method when removing or installing a module permanently. NOTE 3: These buttons are sampled during power-up.
Operation 2-7 Table 2-3 MiniLibrary Base Module Front View Figure Legend Description 1 10-cartridge magazine 2 Magazine security lock 3 Control panel 4 Unlock/Open button 5 Locked indicator 6 Power switch Power Switch The power switch controls the supply of AC power to the module. The switch is recessed into the front panel to prevent accidental power-up or power-down. Press 1 to turn the module ON and press 0 to turn the module OFF.
2-8 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide ■ Use Cleaner (yellow) – indicates that either or both drives require cleaning. A cleaning operation should be done as described in Chapter 5, “Regular Maintenance.” When the Use Cleaner LED lights, you can find out which drive needs cleaning by selecting Cleaning Needed on the drive status submenu. ■ Drive Fault or Loader Fault (red) – lights when a Fault screen appears on the LCD display.
Operation 2-9 Data Unit Figure 2-5 shows the front panel of the Data Unit (Table 2-4). The panel includes a power switch and the control panel, which has pushbuttons, LED indicators, and a display. 1 2 3 4 5 6 SHR-1677 Figure 2-5.
2-10 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Power Switch The power switch controls the supply of AC power to the unit. The switch is recessed into the front panel to prevent accidental power-up or power-down. Press 1 to turn the unit ON, and press 0 to turn the unit OFF. Control Panel The Data Unit control panel (Figure 2-6) contains three LED indicators, a four-line by 20-character backlit LCD display, and four pushbuttons.
Operation 2-11 LED Indicators The three LED indicators on the control panel are labeled Ready (green), Alert (yellow), and Fault (red). ■ Ready (green) - lights when the system is ready to accept commands, either from the control panel or from the host computer via the Expansion Unit. The Ready indicator goes out when you enter Menu Mode. ■ Alert (yellow) - this LED has no function in the Data Unit. ■ Fault (red) – when this LED lights, a Fault screen appears on the display.
2-12 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Starting the System CAUTION: When powering up the MiniLibrary, power must be applied to the Expansion Unit either simultaneously with or after the other modules. If the Expansion Unit is powered on first, its inventory of modules might be incorrect, and the contents of some or all of the modules will be inaccessible to the system and to the host.
Operation 2-13 Initialization Screens After POST completes, the library robotics system is initialized. A series of screens similar to the following appears during this process: COMPAQ TL89x Firmware Level 0X.
2-14 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide The first line shows a numerical FSC. The second line shows a brief description of the error, in place of the words, “Error Description.” The third and fourth lines contain a one- or two-line message describing the initial ERP in place of the words shown in the Fault screen. A list of FSC and ERP appears in Chapter 6, “Diagnostics and Troubleshooting.
Operation 2-15 ■ Hard error ■ In flux ■ Fault The third line in a MiniLibrary Base Module tells the status of the library robotics (loader) within the MiniLibrary Base Module. The possible conditions of the library robotics are: ■ Idle ■ Fetch/stow ■ Taking inventory ■ Checking drives ■ Scanning labels ■ Orphaned cartridge ■ Trapped cartridge ■ Elevator home The fourth line in a Base Module is the magazine map. Numbers 16-25 represent the map numbers of the cartridge slots.
2-16 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide The MiniLibrary System Menu Structure Figure 2-7 shows the structure of the MiniLibrary System menus. Power-Up Displays Default Displays Fault Displays Panel Lock* Main Menu Load/Unload From/To Show Status Menu Library DLT0 DLT1 Map Info.
Operation 2-17 Entering the Menu Mode IMPORTANT: When the Expansion Unit enters Menu Mode, the Ready light goes out. This means that the module is off-line, and responds to all commands from the host with a SCSI Not Ready until you exit Menu Mode and the Ready light comes on. To prevent inadvertent interruption of host operations, you can lock out the Menu Mode using the Security menu. See the section “Security Menu,” later in this chapter.
2-18 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Exiting the Menu Mode To leave the menu mode and return to the Default screen, press the Escape button repeatedly. Each time you press the Escape button, the display moves to a higher menu level. When the Main menu appears, pressing the Escape button once returns you to the Default screen. At this point, the Ready LED lights.
Operation 2-19 The items available on the Show Status menu are: ■ Library ■ DLT0 ■ DLT1 ■ ... ■ DLTn ■ Map Info Move the up or down with the to select the item. and buttons, then press the Enter button Library Status Submenu When you select Library Status, the following scrollable menu appears: Model Number: COMPAQ TL89x Firmware Revision 0X.
2-20 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 2-5 lists the Library Status categories that are available.
Operation 2-21 Table 2-6 lists the Drive Status parameters that are available.
2-22 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide The list of locations available for display on line 1 is as follows: NOTE: If you do not designate any mail slots, those lines are omitted from the list. Depending on the report for each location, Line 2 can display either Empty, or Occupied, or, if a magazine is absent, Not Installed. Depending on the report for each location, Line 3 can display either Label Valid, or Label Not Present.
Operation 2-23 When you select the Security menu, the following scrollable screen appears: Unlock All Panels Unlock All Media Lock All Panels Lock All Media Table 2-7 lists the security functions that are available. Table 2-7 Security Functions Category Category Unlock all panels Unlock all media Lock all panels Lock all media Master locking Module 1 locking ...
2-24 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Your code is shown in place of XXXX. Press the Enter button if you want to adopt the unlock code that appears. Press the Escape button if you do not want to accept it. Press the Escape button again to return to the Main menu, and again to return to the Default screen. The next time you attempt to enter Menu Mode, the following screen appears.
Operation 2-25 Displaying Error Logs To display the error history of the module, you need to use the Show History menu. Access this menu as follows: Fault Code: XXXX Error Description DD/MMM/YYYY HH:MM:SS Entry NNNN Of NNNN Loading and Unloading Tapes The Load/Unload menus let you specify a source and a destination for a cartridge movement. As a result, you use exactly the same procedure to load and unload. To load or unload a tape from the front panel of the module, use the Load/Unload menus.
2-26 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Notice that the is next to line 2 of the display. Line 2 shows the top item in a scrollable list of sources. Note that a has appeared on the right of the bottom line. This indicates that the button can now be used to scroll through the list, and that the top item on the list appears. When you press the button, three things happen: 1. The list scrolls down one item (only line 2 scrolls). 2.
Operation 2-27 Assume that you want to load the cartridge that is in Slot 4 into any available drive. Use the button to scroll line two to Slot 4. Afterwards, the following screen appears: From: Slot4 To: *DLT0 When you scrolled to your desired source, press the Enter button to select it. Notice the two changes that occurred in the display. 1. The * reappears at the beginning of line 2, indicating that you have made a selection. 2. The now moves to line 4, indicating that you can now select a destination.
2-28 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide When you press the Enter button, the following screen appears. If the source is a drive, the word Unload appears in place of the word Load on line 4. From: Slot4 To:DLT0 Load In Progress When the load or unload operation is finished, the Default screen reappears.
Operation 2-29 1 2 SHR-1691 Figure 2-8. Magazine in place Table 2-8 Magazine In Place Figure Legend Description 1 Magazine security lock 2 Unlock/Open button Compaq Confidential – Need to Know Required Writer: Bob Young Project: Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Comments: Part Number: 127510-002 File Name: c-ch2 Operation.
2-30 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Removing a Magazine The following screens help you remove a magazine. Load/Unload Show Status Menu Maintenance Menu Configuration Menu Maintenance Menu Configuration Menu Show History Menu Security Menu Unlock All Panels Unlock All Media Lock All Panels Lock All Media Unlock All Media In Progress Emergency Magazine Removal If a fault occurs that prevents removal of a magazine, turn the power off for 30 seconds.
Operation 2-31 Inserting Cartridges into the Magazine A full magazine is shown in Figure 2-9 (see Table 2-9). Insert cartridges so that the label end with the write protect switch is outward, with the write protect switch toward the bottom of the magazine. The lowest-numbered cartridge slot in the magazine is closest to the handle. 3 1 2 SHR-1692 Figure 2-9.
2-32 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Inserting a Magazine The following screens help you insert a magazine.
Operation 2-33 MiniLibrary Base Module The front panel of the Base Module is nearly identical to the Expansion Unit. It includes a power switch for the module, the magazine door, the magazine security lock, and the Unlock/Open button with its Locked indicator. The control panel, shown in Figure 2-2, has one more LED indicator than the Expansion Unit. Figure 2-10 shows the Base Module front panel (Table 2-10). 1 2 3 Use Cleane r 4 Drive Fault Loader Fault 5 6 SHR-1678 Figure 2-10.
2-34 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Tape Requirements The MiniLibrary system uses ECMA-approved, ANSI proposed-standard DLT tape cartridges. The DLT tape cartridge is a four-inch square plastic cartridge. DLT tapes are available in three types, each with varying length and capacity, as listed in Table 2-11.
Operation 2-35 execute, with resulting errors or hangs, failure to unload, and apparent need to swap out the drive are a few such conditions. NOTE: DLT tape cartridges should be stored vertically, in their original translucent plastic boxes, until you want to reuse them and after they have been removed from tape drives.
2-36 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 1 2 3 SHR-1694 Figure 2-11. DLT tape cartridge Table 2-12 DLT Tape Cartridge Figure Legend Description 1 Leader 2 Write protect OFF 3 Write protect ON Write Protection The write protection switch of a DLT tape cartridge is also shown in Figure 2-11. To enable data recording, slide the write protect switch to the right so that no orange color is visible through the window in the write protect switch 2.
Operation 2-37 Barcode Labels Barcode labels are included with the MiniLibrary and Expansion Unit. Additional labels can be ordered (see Appendix B). The label slips into the slot adjacent to the write-protect switch on each tape cartridge. The code used can be Code 39, Codebar, 2-of-9, standard 2-of-5, or interleaved 2-of-5, with a length of 8 digits. Minimum element width is 0.03 in (07.5 mm).
2-38 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Storage Architecture The MiniLibrary architecture is uniquely suited and designed for expanding storage needs. The MiniLibrary architecture enables the robotics in each of the MiniLibrary components to exchange cartridges with the PTM, and integrates the robotics in the individual components and the PTM into a single high-performance library robotics system.
Operation 2-39 MiniLibrary Base Module The MiniLibrary Base Module has either one or two DLT drives and a 10-cartridge magazine with a random access robotic mechanism. Data Unit The Data Unit has a 16-cartridge magazine, a random access robotic mechanism, and no tape drives. The module robotics, under control of the Expansion Unit, moves cartridges between the PTM and any of the 16 cartridge storage locations.
2-40 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Internal Cabling Configuration The differential MiniLibrary system is wired in an independent-bus SCSI configuration; the robotics and each of the drives has its own SCSI bus. SCSI jumpers are available for those applications requiring that some combination of drives and robotics are daisy-chained to a single SCSI bus.
Operation 2-41 Features Figures 2-12 through 2-16 show some of the external features of the Expansion Unit, the MiniLibrary Base Module, and the Data Unit (see Tables 2-13 through 2-17). 1 2 3 4 5 6 SHR-1677 Figure 2-12.
2-42 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 1 2 3 Use Cleane r 4 Drive Fault Loader Fault 5 6 SHR-1678 Figure 2-13.
Operation 2-43 1 4 3 2 SHR-1680 Figure 2-14. MiniLibrary base module 10-cartridge magazine Table 2-15 MiniLibrary Base Module 10-Cartridge Magazine Figure Legend Description 1 Slot 0 2 Front label slide slot 3 Barcode label slide slot (not used) 4 Slot 9 Compaq Confidential – Need to Know Required Writer: Bob Young Project: Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Comments: Part Number: 127510-002 File Name: c-ch2 Operation.
2-44 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 1 5 4 3 2 SHR-1681 Figure 2-15.
Operation 2-45 1 4 2 3 SHR-1682 Figure 2-16. MiniLibrary base module rear view Table 2-17 MiniLibrary Base Module Rear View Figure Legend Description 1 SCSI bus interface: MiniLibrary (left two connectors) Drive 0 (middle two connectors) Drive 1 (right two connectors) 2 Expansion unit interface 3 Power connector 4 Fan Control Panel The control panels for all modules are the same, except for the number of LED indicators.
2-46 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Display The backlit, 4-line by 20-character control panel display provides a highly intelligible presentation of drive and loader status, menu choices and error messages. The scrolling feature greatly expands the amount of information available to you. In the MiniLibrary Expansion Unit, status information is available for the entire system. The slave modules display other information as needed for localizing malfunctions.
Operation 2-47 The differential unit shown in Figure 2-17 has two ports (Table 2-18). A single-ended version has four ports. 1 2 1 SHR-1683 Figure 2-17. Data unit rear view Table 2-18 Data Unit Rear View Figure Legend Description 1 Power connector 2 Expansion unit interface Integral Fan Cooling A single forced-air fan is mounted inside each module to provide optimum cooling for critical parts, and to prevent the drive and robotics electronics, motors, and power supply from overheating.
2-48 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Library Robotics The DLT MiniLibrary system features library robotics that can load any of the cartridges stored in any magazine in the system into any of the DLT tape drives, moving cartridges among as many as six modules within the DLT MiniLibrary system. The robotics design utilizes the Compaq Library Robotics, which is known for its reliability.
Chapter 3 Installation Introduction This chapter describes the complete MiniLibrary system installation process, from planning and parts identification to mechanical installation, cabling, and configuration. Installation Overview There are three basic areas for installing a MiniLibrary System: mechanical installation, cabling, and configuration. The mechanical installation consists of: ■ Assembling the Pass-Through Mechanism (PTM).
3-2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Cabling consists of: ■ Interconnecting the Data Units and MiniLibrary Base Modules with the Expansion Unit ■ Connecting the Expansion Unit to the PTM motor ■ Connecting the MiniLibrary Base Module drive SCSI buses to host SCSI interfaces ■ Connecting the Expansion Unit to a host SCSI interface ■ Terminating the buses properly Configuration consists of using the Configure menu to customize the configuration options to y
Installation Positioning the Modules The Expansion Unit must be mounted at the top of the stack, which places its control panel at a convenient height. The control panels of the Data Unit MiniLibrary Base Modules are of secondary importance, as they serve mainly to help localize system failures. When installed, the motor drive assembly of the PTM is directly behind the Expansion Unit. Data units and MiniLibrary Base Modules can be installed anywhere below the Expansion Unit, in any order.
3-4 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 1 4 5 2 6 4 5 4 3 6 SHR-1701 Figure 3-1.
Installation Follow the instructions in the section “Mechanical Installation of the Expansion and Base Modules.” After the rack slides and the Base Modules are in place, and after the PTM is assembled, you will install the PTM in the rack by attaching the support braces to the rear of the outer rail slides using the angle brackets. The internal parts you will need to recognize during assembly are shown in Figures 3-2 and 3-3 (see Table 3-2). SHR-1702 Figure 3-2.
3-6 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 1 2 SHR-1703 Figure 3-3. Car rear view showing belt block Table 3-2 Car Rear View Showing Belt Block Figure Legends Description 1 Belt block 2 Captive screws The belt block comes fastened to the back of the car with two captive screws. Carefully note the orientation of the block with respect to the car, as shown in Figure 3-3.
Installation Orientation of Parts During Assembly To determine the orientation of an extension section, examine the flanges on the edges of the section, and note that they are dissimilar. Position the section so that its orientation matches that of the elevator base. Figure 3-4 shows a typical PTM assembly (see Table 3-3). The motor drive section always goes on top, and the base section with the idler pulley always goes on the bottom.
3-8 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 3-3 PTM Assembled Figure Legend Description 1 Support brace 2 Motor drive section 3 Extension section 4 Tie bar 5 Base section Preparing to Assemble the PTM You will need a clean, flat work area such as a table or workbench. The surface should be long enough to support the full height of the PTM.
Installation 3. Center one of the support braces across the rear of the base section over the holes on the rear surface of that section. 4. Insert two M4 x 20 mm Phillips sems screws through the holes in the support brace into the holes in the base section, and tighten. 5. Place pairs of tie bars so that they straddle all of the joints where sections come together. Be sure that the beveled edge is toward the inside corner of the sections. 6.
3-10 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Installing the Belt 1. Turn the assembled PTM over so that the motor points upward (see Figures 3-5 through 3-9). 2. Locate the tensioner ramp in the base section. Press the spring until the hole in the tensioner ramp is aligned with a hole in the base section (Figure 3-5). Insert a 0.050 in Allen wrench or a paper clip through the holes. This sets the idler pulley for zero belt tension. SHR-1705 Figure 3-5.
Installation Table 3-4 Belt Length for Various System Sizes Number of Modules Length of Belt 2 27 in (68 cm) 3 41 in (104 cm) 4 55 in (140 cm) 5 69 in (175 cm) 6 83 in (211 cm) 4. See Table 3-4 for the required belt length for your system. After verifying the length specified, cut the belt between teeth. 5. With the toothed side of the belt toward you, position the right end of the belt about halfway along the PTM. 6.
3-12 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 7. Thread the belt from the motor drive counter-clockwise around the idler pulley and back to the right end (Figure 3-5). 8. Holding the ends of the belt as shown in Figure 3-7, the two ends should be touching or very slightly overlapping. SHR-1707 Figure 3-7. Checking belt length 9. Loosen the four screws that hold the belt retaining plates to the block.
Installation 2 1 3 SHR-1708 Figure 3-8. Belt block with belt in place Table 3-5 Belt Block with Belt in Place Figure Legend Description 1 Belt 2 Gap visible 3 Block 10. Tighten the four screws that hold the belt retaining plates. 11. Pull out the paper clip previously installed in the base section. This applies the proper tension to the belt. 12. Locate the two captive screws in the car.
3-14 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 2 1 SHR-1709 Figure 3-9. Aligning the captive screws with the block Table 3-6 Aligning the Captive Screws with the Block Figure Legend Description 1 Press down 2 Captive screws 15. To steady the belt block, grasp the belt several inches from the block and push toward the back of the track until the block is pressed firmly against the back of the track.
Installation 17. While continuing to press the belt block against the back of the track, begin to tighten the captive screws. When both screws are partially threaded into the belt block, release the belt and finish tightening the screws. Be sure that the block is fully seated against the bracket on the car. Close and secure the door on the car. 18. Using nylon button rivets, install covers over any exposed PTM sections that are not covered by modules.
3-16 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 6. Turn the PTM over and support it so that neither the motor nor the flange at the bottom of the base assembly is touching the work surface. 7. Remove the eight screws holding a pair of tie bars in place (Figures 3-1 and 3-4). Separate the PTM at that joint. You can now add sections as needed and install a new belt as described in the sections “Assembling the PTM” and “Installing the Belt.
Installation Rail Slide Separation 1. See Figure 3-10 and Table 3-7. Separate the inner rail slide from the middle and outer rail slides. 3 2 4 5 1 4 5 SHR-1710 Figure 3-10.
3-18 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 2. Identify and orient the parts of the rail slides and hardware needed for your rack. Figure 3-10 shows the parts required for standard rackmounting. NOTES: All hardware required for rackmounting the Expansion Unit and Base Module into a Compaq rack is supplied. You will need a #2 Phillips screwdriver. The left and right rail slides are alike, so there is no risk of confusing the parts on reassembly.
Installation Installing the PTM in the Rack 1. If you have not done so, install the angle brackets onto the outer rail slides of the top and bottom modules. Use one screw for each angle bracket as shown in Figure 3-11. SHR-1714 Figure 3-11. Installing the PTM in the rack 2. Position the PTM against the back of the installed modules so that the support braces rest on the previously installed angle brackets (Figure 3-11).
3-20 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 5. Repeat steps 3 and 4 at the bottom module. Tighten all screws that hold the PTM to the angle brackets while ensuring that: a. The PTM is centered horizontally, as indicated by the flange engaging the slot on the top and bottom modules. b. It is centered vertically, as indicated by the bottom of the bottom of the PTM being flush with the bottom of the lowest module. c.
Installation 1 5 4 3 2 SHR-1715 Figure 3-12. Expansion unit SCSI connectors and cables (fast wide SCSI shown) Table 3-8 Expansion Unit SCSI connectors and Cables (Fast Wide SCSI Shown) Figure Legend Description 1 Pass-through motor cable connector 2 Power cable 3 Robotics cables to Base Modules 4 SCSI cable 5 Diagnostic connector PTM Motor Cable The PTM motor cable is 36 in (91 cm) long and has a male DB-15 connector on each end.
3-22 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Control Cables Connect each MiniLibrary Base Module or Data Unit to the Expansion Unit using one of the cables with a DB-9 male connector at the base end and a DB-9 female at the Expansion Unit end. A cable is required for each MiniLibrary Base Module. NOTE: Any of the control cables can be connected to any of the DB-9 connectors on the back panel of the Expansion Unit.
Installation In the MiniLibrary Base Module, each drive is wired to an independent bus with a pair of SCSI connectors. Because it can be used in free-standing applications, the MiniLibrary Base Module has a pair of SCSI connectors for that module’s library robotics. The library robotics SCSI interface should not be connected when installed in a system with an Expansion Unit. The Expansion Unit controls the library robotics for all of the modules in the system.
3-24 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Interface Cable Specifications The MiniLibrary is a high-performance system. To avoid degradation of performance, use the highest-quality interface cables. The detailed requirements for SCSI cables are set forth in ANSI X3.131-1994.
Installation ■ Expansion unit: 32 in (81 cm) ■ Cables of different types or impedance should not be used together. Additional specifications to assure the highest SCSI performance can be found in ANSI X3.131-1994 or later. NOTE: This equipment has been tested for electromagnetic emissions and immunity using good quality shielded cables. The use of unshielded cables, poor quality cables or other variances from good practice can result in non-compliance with national and international rules.
3-26 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 7. Measure the cable length to connect the module to the computer system. 8. Be sure that the length of the entire bus falls below the maximum permissible length given in the section, “Interface Cable Specifications.” 1 10 2 3 9 8 7 4 6 5 SHR-1716 Figure 3-13.
Installation Table 3-9 Base Module SCSI Connectors, Terminators, and Cables Figure Legend Description 1 SCSI terminator 2 DLT0 3 DLT1 4 Expansion unit interface 5 Power connector 6 Power cable 7 Fan 8 SCSI cables 9 SCSI interface : Library connectors (not used in slave mode) Compaq Confidential – Need to Know Required Writer: Bob Young Project: Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Comments: Part Number: 127510-002 File Name: d-ch3 Installation.
3-28 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 1 11 2 3 10 9 4 7 8 6 5 SHR-1717 Figure 3-14. Base module SCSI connectors, terminator, jumpers, and cables (SCSI-2 interface, daisy-chained connection shown) Compaq Confidential – Need to Know Required Writer: Bob Young Project: Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Comments: Part Number: 127510-002 File Name: d-ch3 Installation.
Installation Table 3-10 Base Module SCSI Connectors, Terminator, Jumpers, and Cables Figure Legend Description 1 SCSI terminator 2 DLT0 3 DLT1 4 Expansion unit interface 5 Power connector 6 Power cable 7 Fan 8 SCSI jumpers 9 SCSI interface : Library connectors (not used in slave mode) Configuration Individual MiniLibrary Base Modules in all newly assembled systems must be configured as described in the next section.
3-30 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Setting MiniLibrary Base Module (Slave) Configuration IMPORTANT: All MiniLibrary Base Modules are shipped configured as stand-alone systems. Before powering up the Expansion Unit in a MiniLibrary system for the first time, you must reconfigure each of the MiniLibrary Base Modules in the system as a slave. To do so, perform the following procedure on each MiniLibrary Base Module. 1.
Installation 6. Press the screen: button repeatedly to scroll down to select Alternate Config Unit Attn. Report: *All: Alternate Config: *Standalone 7. Press the Enter and then button to change the line to Slave. Press the Enter button again and after selection stops flashing. The following screen appears: Change Not Effective Until Reboot ENTER to Continue 8. Press the Enter button. When the Special Configuration submenu reappears, turn the power switch off to cycle power.
3-32 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 3. Press the button three times to move the to Configure menu, then press the Enter button. The display shows the following Configure submenu screen. Note that the at the end of the fourth line means that there are additional configuration options that can be reached by scrolling with the button. Set Data Format Set SCSI Set Element Base Set Identification 4.
Installation 6. With the next to line 1, press the Enter button. The moves to line 2 and the remains at the end of line 4, and an appears at the end of line 1. Now you can use the and buttons to scroll through the possible settings. Scroll downward so that 3 is displayed, then press the Enter button to save the new selection. An * appears to the left of the 4, to indicate that it is the current selection. 7. Press the Escape button repeatedly until the following submenu reappears.
3-34 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 3. With the next to line 1, press the Enter button. The moves to line 2 and appears at the end of line 4. Now you can use the and buttons to scroll line 2 to display the possible settings. These options enable you to specify which module should have the mail slot enabled. Scroll downward to the desired module, then press the Enter button to save the new selection. NOTE: The Expansion Unit is not on the list.
Installation 3. With the next to line 1, press the Enter button. The moves to line 2, a appears at the end of line 4, and a appears at the end of line 1. Now you can use the and buttons to scroll line 2 to specify the number of slots to be reserved. Scroll to the desired number, then press the Enter button to save the new selection. 4. Press the Escape button repeatedly to return to the Default screen.
3-36 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 3-11 MiniLibrary Configuration Options continued Option Setting Set Library Mode (1) Library Mode: *Random Sequential DLT 0 Sequential DLT 1 Sequential Split If Sequential Mode: *Normal Recirculate Set Element Base Set Element Base: Transport Base *0x0000 NNNN (hex) Storage Base *0x0001 NNNN (hex) Transfer Base 0x00F0 NNNN (hex) Set Identification Vendor ID: * DEC Product ID: *TL800 (c) DEC < Vendor
Installation Table 3-11 MiniLibrary Configuration Options continued Option Setting Set Time Hour: HH Minute: MM Set Baud Rate Baud Rate: *38,400 Auto 2,400 9,600 19,200 38,400 57,600 115,200 Set serial number Serial number field Set Unload Mode Unload Mode: *Implicit Explicit Set Auto Clean Mode Auto Clean: *Disabled Enabled Set Negotiation Mode Negotiation Mode: *Do Not Initiate Initiate Transfer Rate: *Sync. 10 MB/sec Sync. 5 MB/sec Asynch. Only Set Mail Slot (2) Mail Slot Emul.
3-38 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide The items available on the Configuration menu are: 1. Set Data Format: This setting lets you: a. Set the data format to Auto Selection, THZ01, THZ02, DLT2000, DLT2000XT, DLT4000, DLT7000, or DLT8000. b. Auto Selection, enable, and disable data compression. Compression can not be enabled when either THZ01 or THZ02 format is in use. This setting applies to the next or currently loaded cartridge only.
Installation 4. Set Element Base: This setting lets you set the base addresses of each of the four SCSI elements of the module. In order to identify sources and destinations in commands to the robotics, the MiniLibrary System is divided into elements, each of which is assigned a separate designator or element address.
3-40 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 10. Set Negotiation Mode: This option offers two choices: Initiate Negotiation and Set Transfer Rate. Initiate Negotiation, if set, enables the MiniLibrary System to initiate SCSI Synchronous Negotiation with the host (the default is No). The Expansion Unit always responds to host-initiated negotiation. Set Transfer Rate can be set to 10 Mbytes/sec, 5 Mbytes/sec or Asynchronous. The default is 10 Mbytes/sec. 11.
Installation Table 3-12 MiniLibrary Special Configuration Options Set Special Configuration Option Settings Default Mode Page 1F Length Short (0 x 0E) Short (0 x 0E) Long (0 x 12 Model Number Compaq TL89X Compaq TL89X TUR Reporting Standard Custom Custom Init. Element Status No Inventory Force Inventory Force Label Scan Force Inventory Unit Attn Report All All One Alternate Config.
3-42 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 3-12 MiniLibrary Special Configuration Options continued Set Special Configuration Option Settings Default Set Special Configuration Option Settings Default Door Open Response (Expansion Unit ) Ready Not Ready Ready SCSI Mode SCSI-2 SCSI-3 SCSI-2 Post Recv’d Error Disabled Enabled Disabled Tape Alert Mode Logging Disabled No exceptions Unit Attention Rec. Error (cnd) Rec.
Chapter 4 Configuration Configuration Overview This chapter describes how to customize the configuration of the MiniLibrary Base Module and defines configuration options. The MiniLibrary Base Module is designed with several configuration options, each offering multiple settings to support a variety of applications and platforms. The setting of each option is stored in non-volatile memory in the module. For most applications, you will not need to change the factory default settings.
4-2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Customizing Your Configuration To customize your configuration: 1. Turn the Base Module on, and wait until the POST terminates and the following Default screen appears. Yours might vary depending on the number of drives in your MiniLibrary system (second line), and the number and locations of cartridges in the magazine (fourth line). DLT0 Active DLT1 Idle Loader Idle 012_4_6789 2. At the Default screen, press the Enter button.
Configuration 5. Press the Enter button to select DLT0, or, to select DLT1, press the button to move the next to DLT1, then press the Enter button. The following submenu for the Set Data Format option appears: DLT1 Density: *Auto. Selection DLT1 Compression: *Disable As the submenu shows, the on the display is next to line 1, and line 2 is indented. This tells you that it is a two-tiered menu. The and buttons work on two levels in this kind of menu, which is typical of many submenus of the Configure menu.
4-4 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Descriptions of Configuration Options The items available on the Configuration menu follow. Set Data Format This setting lets you: 1. Set the data format to Auto Selection, THZ01, THZ02, DLT2000, DLT2000XT, DLT4000, DLT7000, or DLT8000. 2. Auto Select, enable, and disable data compression. Compression cannot be enabled when either the THZ01 or THZ02 format is in use.
Configuration Set Library Mode This option lets you set the MiniLibrary system robotics operating mode to Random, Sequential DLT0, Sequential DLT1, or Sequential Split. Random is the normal operating mode which affords complete host control of the MiniLibrary system robotics. The Sequential modes are locally controlled modes. Sequential DLT0 begins with any cartridge loaded into DLT0.
4-6 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 3. Press the twice so that the is next to Set Library Mode and then press the Enter button. The following Library Mode Selection menu appears: Library Mode: * Random 4. Press Enter again so the options are: ■ ■ is next to *Random.
Configuration The following Special Config submenu appears: Mode Pg 1F Length * Short (0x0E) Model Number * Compaq TL89X Press twice to position the next to the TUR Reporting option. Press the Enter button to move down one line to *Standard. Use the to change to Custom and press the Enter button to accept this setting. To return the Base Module to online status, press the Escape button three times.
4-8 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Set Date This command lets you set the Base Module calendar. Tables 4-1 and 4-2 list the configuration settings for the MiniLibrary system Base Module. NOTE: The options described in Table 4-1 and Table 4-2 represent the version of the firmware in use when this manual was written.
Configuration Table 4-1 MiniLibrary Configuration Options Option Setting Set Data Format DLT n Density: * Auto Selection THZ01 THZ02 DLT2000 DLT2000XT DLT4000 DLT7000 DLT8000 DLT n Compression: * Auto Selection On Off Set SCSI Library Parity: *Enabled Disabled Library Bus ID: *0 0-15 DLT0 0 Bus ID: *4 0-15 DLT 1 Bus ID: *5 0-15 continued Compaq Confidential – Need to Know Required Writer: Bob Young Project: Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Comments: Part Numbe
4-10 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 4-1 MiniLibrary Configuration Options continued Option Setting Set Library Mode (1) Library Mode: *Random Sequential DLT 0 Sequential DLT 1 Sequential Split If Sequential Mode: *Normal Recirculate Set Element Base Set Element Base: Transport Base *0x0000 NNNN (hex) Storage Base *0x0001 NNNN (hex) Transfer Base 0x00F0 NNNN (hex) Set Identification Vendor ID: * DEC Product ID: *TL800 (c) DEC < Vendor
Configuration Table 4-1 MiniLibrary Configuration Options continued Option Setting Set Time Hour: HH Minute: MM Set Baud Rate Baud Rate: *38,400 Auto 2,400 9,600 19,200 38,400 57,600 115,200 Set serial number Serial number field Set Unload Mode Unload Mode: *Implicit Explicit Set Auto Clean Mode Auto Clean: *Disabled Enabled Set Negotiation Mode Negotiation Mode: *Do Not Initiate Initiate Transfer Rate: *Sync. 10 MB/sec Sync. 5 MB/sec Asynch. Only Set Mail Slot (2) Mail Slot Emul.
4-12 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 4-2 MiniLibrary Special Configuration Options Set Special Configuration Option Settings Default Mode Page 1F Length Short (0 x 0E) Short (0 x 0E) Long (0 x 12 Model Number Compaq TL89X Compaq TL89X TUR Reporting Standard Custom Custom Init. Element Status No Inventory Force Inventory Force Label Scan Force Inventory Unit Attn Report All All One Alternate Config.
Configuration Table 4-2 MiniLibrary Special Configuration Options continued Set Special Configuration Option Settings Default Set Special Configuration Option Settings Default Door Open Response (Expansion Unit ) Ready Not Ready Ready SCSI Mode SCSI-2 SCSI-3 SCSI-2 Post Recv’d Error Disabled Enabled Disabled Tape Alert Mode Logging Disabled No exceptions Unit Attention Rec. Error (cnd) Rec.
4-14 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Set Unload Mode This option determines whether a SCSI MOVE MEDIUM command is interpreted as implicit or explicit. If implicit, when the Base Module receives a SCSI MOVE MEDIUM command for a fetch from a drive, it unloads the drive before attempting to fetch a cartridge from that drive. If explicit, the host must issue a SCSI UNLOAD command before each MOVE MEDIUM command where the source element is a drive.
Configuration Set Reserve Slot Some host software imposes size limits on tape library magazines for licensing purposes, and will not operate with a MiniLibrary system that exceeds the licensed size. This configuration option lets you withdraw some of the slots in the Expansion Unit from use as storage slots in order to meet licensing requirements. Also used to set one or more slots as reserved for the auto clean function.
Chapter 5 Regular Maintenance Introduction This chapter describes the procedures for running and replacing the cleaning cartridge in the MiniLibrary system. The only regular maintenance task that should be periodically performed is running or replacing the cleaning cartridge.
5-2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide A diagnostic diskette (Microsoft Windows NT and Windows 95/98 Operating Systems) that allows for firmware updates, via the diagnostic port, is included in the Accessories Kit. This chapter explains how to clean the drives. The Diagnostic menu and the Demo menu are described in Chapter 6, “Diagnostics and Troubleshooting.” Cleaning Cartridge The cleaning cartridge is similar in appearance to the data cartridge, but is yellow.
Regular Maintenance Running the Cleaning Cartridge This procedure assumes that the cleaning cartridge has been installed into Slot 0 of the magazine. 1. At the Default screen, press the Enter button. The following screen appears: Load/Unload Show Status Menu Maintenance Menu Configure Menu 2. Press the button twice to move the next to Maintenance, then press the Enter button to select the Maintenance menu. A screen similar to the following appears: Clean Drive Diagnostic Menu Demo Menu Flash Update 3.
5-4 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide When you press the Enter button, The following screen appears: Clean: Use: DLT0 Slot0 Cleaning In Progress When the cleaning operation completes, the Default screen reappears. Removing the Cleaning Cartridge NOTE: If the Base Module is installed in a sufficiently secure area, you can elect not to use the magazine security lock. In that event, leave the lock in the unlocked position. 1.
Chapter 6 Diagnostics and Troubleshooting Introduction This chapter describes the procedures for diagnosing platform problems and drive errors that can cause the MiniLibrary system to malfunction. It also provides Fault Symptom Codes (FSCs) and Error Recovery Procedures (ERPs) to help restore operability. Diagnosing Problems There are two main types of problems that can cause the MiniLibrary system to malfunction or fail to perform correctly: platform problems and general drive errors.
6-2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide General Drive Errors These errors usually result from a miscommunication between the drive processors or involve a mechanical malfunction. In most cases, these types of errors report an error message and an FSC to the control panel. The only exceptions are power supply problems and display malfunctions. The FSC can be used to determine a recovery procedure.
Diagnostics and Troubleshooting TROUBLESHOOTING AND ERROR RECOVERY ERROR, FAULT, MALFUNCTION Determine Suspected Error Type PLATFORM No FSC displayed. Normal front panel operation GENERAL DRIVE FSC and ERP displayed on control panel Cycle the power to the library Follow the ERP on the control panel Retry Find FSC in Table 6-2 Check configuration in Ch.
6-4 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Error Recovery Procedures Table 6-1 lists error recovery instructions for errors reported on the front panel. This list includes procedures that should only be performed by a qualified service technician. Table 6-1 Error Recovery Procedures ERP Number Procedure Detail A Run the cleaning cartridge. See Chapter 5, “Regular Maintenance.” B Change the cartridge. It might be damaged or incorrectly formatted.
Diagnostics and Troubleshooting Table 6-2 System Error Codes (0xxx) FSC Message Description 0101 Unused Interrupt An undefined interrupt occurred. 0102 Enqueue'g a Null Ptr A NULL pointer was passed to one of the enqueing functions. This is generally a firmware bug. 0103 Invalid Cmd Rec'd An illegal trace command was received by the trace process. 0201 Trc Comm Open Error The trace port could not be opened. 0301 Novram Init Error A failure occurred when trying to initialize the NOVRAM.
6-6 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 6-2 System Error Codes (0xxx) continued FSC Message Description 0701 Slv Comm Open Error Failed to open a Slave comm port. 0801 Not In Br. Menu Mode The device is not in browser menu mode. 0802 Invalid Novram Upd. An invalid NOVRAM update occurred in browser mode. 0803 Executing Immed. Cmd Executing an Immediate command in browser mode.
Diagnostics and Troubleshooting Table 6-3 SCSI Error Codes (1xxx) continued FSC Message Description 1022 SCSI Invalid Semaphore Firmware error. 1023 SCSI Invalid State Firmware error. 1024 SCSI Invalid Ctl Msg A message sent from the control process was not valid. 1025 Overlapped Ctl Cmds The control process sent a command while one was in process. 1026 Overlapped Ctl Msgs The control process sent a message while one was in process. 1027 Control Process .
6-8 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 6-4 Control Error Codes (2xxx) continued FSC Message Description 2008 Illegal Move While attempting to perform a MOVE operation, the source or destination locations were in the wrong state (FULL or EMPTY).This also occurs if the MOVE is attempted with an invalid cartridge map. 2009 Door Open A command was received while the door was open. 200A Menu Mode A command was received while the unit was in Menu mode.
Diagnostics and Troubleshooting Table 6-4 Control Error Codes (2xxx) continued FSC Message Description 2030 DLT Timeout Error During power up, communication with one of the DLT drives was unsuccessful. 2031 DLT Timeout Error While trying to update the front panel, communication with one of the DLT drives was unsuccessful. 2032 DLT Timeout Error Communication with DLT drive 0 was unsuccessful (sequential mode).
6-10 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 6-4 Control Error Codes (2xxx) continued FSC Message Description 2073 Drive Config Error Set if the Alternate Unload has not been selected. This currently applies only to DLT7000’s and DLT8000’s with a controller microcode revision greater than 50. 2074 Stow Error A stow timeout error has occurred when accessing a remote unit. Press the Enter button to reboot for orphan cartridge recovery.
Diagnostics and Troubleshooting Table 6-5 Motor Process Error Codes (3xxx) continued FSC Message Description 300C Picker Open Tach Open Tach detected on picker motor. 300D Door Open Tach Open Tach detected on door motor. 300E Drive Stow Error A problem was encountered while trying to stow a cartridge to a drive. Couldn’t close the door. 300F Slave Init Error Check the Pass-Through Mechanism (PTM) access plate removed at the rear of the MiniLibrary Base Module.
6-12 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 6-5 Motor Process Error Codes (3xxx) continued FSC Message Description 3103 Picker Jammed While stowing to a bin, the picker moved too far. This generally occurs if the arm slips in between two cartridges during the final push. 3104 Picker Jammed During a bin stow, the picker did not reach a position far enough to insure that the cartridge was fully inserted.
Diagnostics and Troubleshooting Table 6-6 Power-On Error Codes (4xxx) FSC Message Description 4001 ROM CRC Error 4002 Ram Test Failed You chose the Load/Unload menu selection, but no DLT drives are currently attached to the MiniLibrary system. 4003 Xilinx Progr Error You chose the Load/Unload menu selection, but all drive and slot locations are currently devoid of tape cartridges.
6-14 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 6-7 Power-On Error Codes (5xxx) continued FSC Message Description 5004 No Slots Installed You chose the Load/Unload menu, with no magazine. 5010 No DLTs Attached You chose the Clean Drive menu selection, but no DLT drives are currently attached to the MiniLibrary system. 5011 All Slots Empty You chose the Clean Drive menu selection, but all slot locations are currently devoid of tape cartridges.
Diagnostics and Troubleshooting Table 6-7 Power-On Error Codes (5xxx) continued FSC Message Description 5031 Bad Calendar Setting A time or date setting obtained from the real-time clock, which was indicated as being running, nevertheless was determined to be invalid. 5032 Bad Setting A default setting was determined to be invalid. 5033 Set Density Failed You chose the DLT Density menu selection, but the chosen DLT has failed to successfully execute the density change request.
6-16 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 6-8 Intermodule Error Codes (6xxx) FSC Message Description 6001 Comm Open Error An attempt to open the RS-232 serial communication port used by the inter-module processes failed. 6002 Comm Port Send Error An inter-module process (Master or Slave) was sending a packet to a remote module, but the UART detected an error condition during the transfer.
Diagnostics and Troubleshooting Table 6-8 Intermodule Error Codes (6xxx) continued FSC Message Description 6015 Ack Timeout - Out The Master inter-module process attempted to initiate a packet transmission to a Slave intermodule process, but a timeout occurred waiting for the Slave’s acknowledge. 6016 Ack Timeout - In The Master inter-module process attempted to initiate a packet transmission from a Slave intermodule process, but a timeout occurred waiting for the Slave’s acknowledge.
6-18 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 6-8 Intermodule Error Codes (6xxx) continued FSC Message Description 6024 Slave Has No Pkts The Master inter-module process is requesting the Slave to send a packet, but the Slave has no packets to send. 6025 Pkt ID Invalid 6026 No Slaves to Flash 6027 Master Has No Flash 6028 Slave Unavailable 6029 Slave Has No Flash 6030 Slave Dev.
Diagnostics and Troubleshooting Table 6-8 Intermodule Error Codes (6xxx) continued FSC Message Description 6044 Invalid Com Blk Type A Slave inter-module process received a packet from the Status/Message queue, but the packet’s CommBlock type was invalid. 6045 Command Overlap A Slave inter-module process received a Command from the Master inter-module process, but a previously issued command is still being executed.
6-20 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table 6-9 Boot Error Codes (Bxxx) continued FSC Message Description B010 Boot UART 0 Error B011 Boot UART 1 Error B012 Boot UART 2 Error B013 Boot UART 3 Error B014 Boot UART 4 Error Table 6-10 Flash Error Codes (Fxxx) FSC Message F001 No Flash Installed F002 Invalid Comm Port F003 Could Not Open Comm F004 Host Sync Failed F005 Invalid H/W Config F006 Incompatible Image F010 Flash Erase Error F011
Diagnostics and Troubleshooting Using System Diagnostics The system diagnostics are intended to be used by a CE or other technically trained person. To use system diagnostics: 1. At the Default screen, press the Enter button. The following screen appears: Load/Unload Show Status Menu Maintenance Menu Configure Menu 2. Press the button twice to move the next to Maintenance, then press the Enter button to select the Maintenance menu.
6-22 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Cartridge Cycle Diagnostic When you select Cartridge Cycle, the MiniLibrary system robotics begin to move cartridges randomly from slot to slot in the magazine, while reporting on the front panel the number of passes. This diagnostic runs continuously as long as the Base Module has power. To stop the test, press the Escape button. A flashing message appears on the display telling you that the test is paused.
Appendix A Specifications Introduction This appendix lists the specifications and regulatory requirements met by the MiniLibrary system, Expansion Unit, Data Unit, and MiniLibrary Base Module(s).
A-2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table A-1 Operational Performance Specifications continued Description Specification Tape speed DLT20/40 DLT35/70 DLT40/80 110 in/s read/write, 150 in/s search 160 in/s read/write, 175 in/s search 168 in/s read/write, 175 in/s search Tape tension 3.0 +/- 1 oz when stationary 4.
Specifications Table A-2 Reliability Specifications (Drives) Description Specification Mean cycles between operator intervention 150,000 Data error rate (recoverable) 1 in 10 bits MTBF 250,000 hr (unlimited duty cycle) MTTR 15 min Head life 50,000 tape motion hrs Design life 7 yrs @ 3,300 power-on hrs/year 17 Table A-3 Reliability Specifications (MiniLibrary System Robotics) Description Specification Life expectancy, load/unload operations 500,000 Design life 7 yrs Table A-4 Power Spec
A-4 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table A-5 Mechanical Specifications Description Specification Height 6.97 in (17.70 cm) Width 17.00 in (43.18 cm) Depth: Overall Behind panel 23.75 in (60.35 cm) 22.75 in (57.
Specifications Table A-7 Environmental Specifications (Packed or Unpacked) Description Specification Dry bulb temperature 41°F to 104°F (5°C to 40°C) Temperature gradient 36°F (20°C)/hr (across the range) Temperature shock 27°F (15°C) (over 2 min) Wet bulb temperature 86°F (30°C) Relative humidity (non-condensing) 40% to 60% Humidity gradient 10%/hr Altitude -1000 ft to +10,000 ft (-305 m to 3050 m) Table A-8 Environmental Specifications (Storage/Transit) Description Specification Dry bul
A-6 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Safety The MiniLibrary Base Module, Expansion Unit, and Data Unit carry the following Regulatory Agency product safety certifications. Table A-10 Regulator Agency Product Safety Certifications Description Specification Certification Standard UL Listed UL 1950 TUV/Product Service EN 60 950 GS Mark CE Mark EMC Directive, Low Voltage Directive Canadian UL Listed CSA 22.2 No.
Specifications Electromagnetic Emission (EM) Notice This equipment has been tested using double shielded cables for EM compliance. The use of unshielded cables or modifications requires system testing for EMI testing for compliance to the standard. Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference-causing equipment regulations.
A-8 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Acoustic Noise Declaration Table A-11 Acoustic Noise Declaration Declared per ISO 9296 and ISO 7779 Sound Power Level LW Ad, B Sound Pressure Level LpAm, dBA (bystander position) Product Idle Operate Idle Operate TL881/TL891 Family MiniLibrary System 6.4 7.0 48 48 NOTE: Current values for specific configurations are available from Compaq representatives 1 B = 10 dBA.
Specifications FCC and VCCI Requirements The following FCC and VCCI notices apply to the TL881/TL891 Family MiniLibrary System. Statement for Equipment Meeting FCC Class A Requirements This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules.
A-10 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Equipment Meeting VDE Class B Requirements (VFG 1046/84 and VFG 243/91 for Germany) Für Bundesrepublik Deutschland For Federal Republic of Germany Pour la République féderal d’Allemagne Bescheinigung des Herstellers/Importeurs Dieses Gerät ist Übereinstimmung mit den Bestimmungen der BMPT Vfg. 243/1991 und Vfg. 46/1992 in Verbindung mit EN55022:1987 (DIN VDE 0878-3:11.89) oder Vfg. 1046/1984 mit Vfg. 483/1986, funkentstört.
Specifications VCCI Notice for Japan Class I Equipment Japanese Voluntary Control Council for Interference (VCCI). This equipment is in the 1st Class category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Information Technology Equipment aimed at preventing radio interference in commercial and/or industrial areas.
Appendix B Accessories Introduction This appendix lists the supplies available for the TL881/TL891 Family MiniLibrary System. Data and Cleaning Cartridge Ordering Information You can order additional CompacTape Data or Cleaning Cartridges for the TL881/TL891Family MiniLibrary System by contacting your authorized Compaq reseller or by calling Compaq ordering service at 1-800-345-1518. Table B-1 lists cartridge ordering part numbers.
B-2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Table B-1 Data and Cleaning Cartridge Part Numbers New Part Number Old Part Number Description 199702-001 TK85K-01 CompacTape III Data Cartridge (quantity, 1) 242465-001 TK87X-01 CompacTape IIIXT Data Cartridge (quantity, 1) 295194-B21 TK88K-01 CompacTape IV Data Cartridge (quantity, 1) 295195-B22 199704-001 199680-002 TL891DLX CompacTape IV Data Cartridge (quantity, 1) TK85-HC TL891 Cleaning Tape Cartridge (quanti
Appendix C Product Notes for Microsoft Windows NT and Novell Netware Introduction This appendix provides information for the system administrator who should read this appendix before installing and using DLT tape drives with a host system operating under the Windows NT or Novell NetWare operating systems.
C-2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Host SCSI Interface Compaq has tested and supports DLT tape drives under the Windows NT and Novell NetWare operating systems. The DLT tape drives use the standard SCSI-2 command set to interface to a PC-based host system. The host system must be equipped with a SCSI adapter to properly interface the tape drive with the host.
Appendix D Adding a Second Tape Drive Introduction This appendix explains how to add a second tape drive to the TL881/TL891 Family MiniLibrary System. IMPORTANT: All screws that do not use lock washers, captive washers or lock nuts must have Loctite 222 applied when parts are reassembled in the field. If you ignore this step, you could cause premature failure of the mechanism.
D-2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Parts Location Figure D-1 shows the location of most of the field-replaceable parts. 5 6 4 3 2 7 1 8 9 14 13 12 11 10 SHR-1719 Figure D-1.
Adding a Second Tape Driv Table D-1 Parts Location continued Figure Legend Description : AC power switch ; Control panel < Unlock/Open button and locked indicator = Magazine security lock > Leadscrew Overall Procedure NOTE: If the Base Module is part of an expanded TL881/TL981 Family MiniLibrary System, refer to the Compaq StorageWorks TL881/TL890/TL891 Family MiniLibrary System Maintenance and Service Guide for information on removing the Base Module from the MiniLibrary system.
D-4 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Removing and Replacing the Skin Cover (Desktop Models Only) The skin cover is held in place by two screws on each side of the Base Module (Figure D-2). SHR-1720 Figure D-2. Removing the skin cover Removing To remove the skin cover from the Base Module: 1. Remove the two screws on each side of the Base Module. 2. Grasp the cover at the lower edge of each side and then lift it straight up.
Adding a Second Tape Driv Replacing To replace the skin cover on the Base Module: 1. Slide the skin cover over the module until it touches the front panel. 2. Insert the four screws (2 each side) through the skin cover into the Base Module. Do not tighten the screws yet. 3. Position the front edge of the skin cover so that it is flush against the back of the front panel. 4. Tighten the four screws (2 each side) into the Base Module.
D-6 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 4. Connect the power and interface cables at the rear of the module. 5. If the Base Module is a desktop model, replace the skin cover as described in “Removing and Replacing the Skin Cover (Desktop Models Only).” SHR-1721 Figure D-3. Removing the cover plate Removing and Replacing the Drive Caddy Assembly The drive caddy assembly is an enclosure that holds one or two DLT drives and the interconnecting cables.
Adding a Second Tape Driv Removing Remove the drive caddy assembly from the Base Module: 1. Remove the cover plate as described in “Removing and Replacing the Cover Plate.” 2. Disconnect the SCSI cable connectors ( 1 Figure D-4) from the controller SCSI extension cable. 7 5 2 1 7 5 3 4 6 4 SHR-1722 Figure D-4.
D-8 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 3. Disconnect the drive power Y cable 2 from the power supply connector. 4. Disconnect the drive 1 RS-422 cable 3 from the controller PWB end. 5. Remove two M4 x 8 mm flat-head screws 4 from along the upper edge of the drive caddy assembly. 6. Remove two M4 extension screws 5 from the top of the drive caddy assembly.
Adding a Second Tape Driv 5. Connect the drive power cable 2 to the power supply connector. 6. Connect the SCSI cable connectors 1 to the controller SCSI extension cable. 7. Replace the cover plate as described in “Removing and Replacing the Cover Plate.” Installing the Second Tape Drive To install the second tape drive: 1.
D-10 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 9. Install the RS-422 cable supplied with the kit, sliding it under the clamps so that the connector is adjacent to the connector on top of the new drive. 10. Install the RS-422 cable removed in step 3 over the top of the new RS422 cable so that the connector is adjacent to the connector on top of the original drive. 11.
Appendix E Information on Pass-Through Section Covers Introduction This appendix supplements the information presented in the section “Mechanical Installation” of Chapter 3. IMPORTANT: These procedures should be performed by a qualified service technician. Pass-Through Section Covers The Pass-Through Mechanism (PTM) moves tape cartridges vertically between the TL881/TL891 Family MiniLibrary System modules. Each module section is covered by an individual sheet-metal enclosure.
E-2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide IMPORTANT: Both parts of the covers must remain in place over any section of the mechanism that is not behind a MiniLibrary system module. Any gaps between modules should remain completely covered. Figure E-1 shows the cover assembly side plate 1 and Figure E-2 shows the mechanism section cover 2. 1 SHR-1723 Figure E-1. Cover assembly side plate 2 SHR-1724 Figure E-2.
Appendix F Tape Drives and Cartridges Introduction This appendix discusses: ■ Care and handling of cartridges ■ Preparing cartridges for use ■ Adding and removing cartridges through the load port ■ Adding and removing cartridges through the storage array door ■ Using the tape drives ■ Removing cartridges from the tape drives Compaq Confidential – Need to Know Required Writer: Bob Young Project: Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Comments: Part Number: 12
F-2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Care and Handling of Cartridges CompacTape is a Digital Linear Tape (DLT) that has been designed and formulated for use in DLT tape drives and tape libraries. The high-grade metal particle tape features demonstrated tape durability and a long archival life. As with any data storage medium DLT tape cartridges require some care in handling and storage. The following guidelines will help protect your valuable data.
Tape Drives and Cartridges ■ The ambient operating environment for the tape cartridge is: Temperature: 50°F to 104°F (10°C to 40°C) Relative Humidity: 20% to 80% (non-condensing) If storage and/or transportation of a tape cartridge has exposed it to conditions outside the ambient values above, allow the cartridge to remain unused in its operating environment for 24 hours before using it.
F-4 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 1 2 SHR-1725 Figure F-1. Opening the cartridge door Table F-1 Opening the Cartridge Door Figure Legend Description 1 Slide lever 2 Cartridge (takeup) leader 4. Verify that the cartridge (takeup) leader appears in its normal position (protrudes about a 5-degree angle from the case.) If necessary, compare it to a cartridge that has not been dropped.
Tape Drives and Cartridges 1 2 3 4 7 5 6 8 SHR-1726 Figure F-2.
F-6 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 5. Verify that the two reel lock levers are in position: one is located on the same surface as the cartridge leader door, the other is located on the bottom of the cartridge near the front left-hand corner. Both reel locks should be visible and in the same position as a cartridge that has not been dropped. 6. Verify that the hub reel is flush with the case surface. If the hub reel is compressed it could become misaligned.
Tape Drives and Cartridges Transportation Guidelines Keep within the following environmental guidelines as listed in Tables F-3 and F-4. Table F-3 Unrecorded (Blank) Cartridges Description Specification Temperature -10°F to 118°F (-23°C to 48°C) Relative humidity 5% to 100% Wet bulb temperature Duration 48.
F-8 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide ■ Condition newly received cartridges in their operating environment for at least 24 hours before use. ■ Minimize potential damage from stray magnetic fields by ensuring a nominal spacing of not less than 3.2 in (80 mm) between the cartridge and the outer surface of its shipping container.
Tape Drives and Cartridges Table F-5 Cleaning Cartridge Guidelines Problem Cause Solution The Use Cleaning Tape LED Lights. The drive heads need cleaning or the tape is defective. Try another tape. Use the cleaning cartridge if the LED stays on. The cleaning operation begins automatically as soon as the cartridge insert/release handle is closed. When cleaning is complete, the internal beeper sounds to tell you to remove the cleaning cartridge.
F-10 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Cleaning the Tape Drive Heads The tape drive heads physically read and write data to and from the tape cartridge. Under normal conditions, the heads require cleaning only when the Use Cleaning Tape LED indicates that it is required. IMPORTANT: Never attempt to clean the heads in a manner other than described in the following procedure. Doing so can void the product warranty. To clean the heads: 1.
Tape Drives and Cartridges Preparing Cartridges for Use The MiniLibrary system comes with one DLT tape cartridge and one cleaning cartridge. IMPORTANT: The MiniLibrary system accepts only CompacTape III, CompacTape IIIXT, and CompacTape IV cartridges. For best performance, use CompacTape IV cartridges in the MiniLibrary system. Do not use CompacTape I or CompacTape II cartridges. NOTE: To order additional tape cartridges, contact you Compaq authorized dealer or reseller.
F-12 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide 1 SHR-1727 Figure F-3. Applying a bar code label Compaq Confidential – Need to Know Required Writer: Bob Young Project: Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Comments: Part Number: 127510-002 File Name: m-appf Tape Drives and Cartridges.
Tape Drives and Cartridges Write-Protecting and Write-Enabling Cartridges Each DLT cartridge has a write-protect switch 1 and an orange protection tab 2. Use the switch as follows: 1. To write-protect a cartridge (prevent data from being written onto the tape), move the switch to the left. The orange tab appears. 2. To write-enable a cartridge (allow data to be written), move the switch to the right. The orange tab disappears.
F-14 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Using the Tape Drives Each tape drive has a control panel consisting of status indicators (lights) and buttons. Each tape drive control panel can be accessed only with the outside cover removed. It is best to use only the MiniLibrary front panel to control the tape drives. 6 e e rit ot W Pr 2. ed ct 0 6. .0 e pe U s Ta In 10 /1 0 20 5. .0 U 35 1 g e in at le an e per nd se le ap O Ha C T .
Tape Drives and Cartridges Table F-7 Tape Drive Control Panel Figure Legend Name Function 1 Write Protect indicator (orange) Lights when the loaded tape cartridge is writeprotected. 2 Tape in Use Indicator (yellow) Blinks while the tape cartridge loads and calibrates. After calibration, it remains lit. If the indicator remains on after a cleaning cartridge is unloaded, the drive heads were not adequately cleaned.
Appendix G Interconnect Characteristics for Signals Table G-1 Recommended Minimum Conductor Size SE 3 m Cable All conductors except terminator power and reserved Single terminator power line Multiple terminator power lines LVD 6 m Cable 2 12 m Cable 2 >12 m Cable 2 25 m Cable 0,050 92 mm 0,080 42 mm 0,032 4 mm 0,080 42 mm 0,050 92 mm2 (30 AWG) (28 AWG) (32 AWG) (28 AWG) (30 AWG) 0,080 42 mm2 0,080 42 mm2 N/A N/A N/A (28 AWG) (28 AWG) 2 2 HVD 0,050 92 mm 0,050 92 mm2 0,032 4 mm2
Index A C Accessories B-1 Adding a Second Drive overall procedure D-3 Adding to an Existing PassThrough Mechanism 3-15 Advanced Design Features 1-14 Archival Guidelines F-6 Assembling the Pass-Through Mechanism 3-8 Cable Specifications 3-24 Cabling 3-2 Capacity 1-15, 2-40 Care and Handling of Cartridges F-2 Cartridge Handling and Storage 2-34 CE Diagnostics 6-21 Checking a Cartridge for Damage F-3 Cleaning Cartridge 5-2 Cleaning Guidelines F-8 Cleaning the Tape Drive Heads F-10 Commands SCSI IMPORT/EXPO
2 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Compression 1-15 data 1-15 Configuration 2-40, 2-45, 3-2, 3-29 overview 4-1 Configuration Options 3-35, 4-4 Configure Menu 2-22 Considerations SCSI bus performance 1-7 Control Cables 3-22 Control Panel 1-12, 2-45 button functions 2-5 Cover Plate removing and replacing D-5 Covers removing and replacing D-4 Customize Configuration 4-2 D Daisy-Chained SCSI 2-40 Data and Cleaning Cartridge Ordering Information B-1 Data Transfer Rate
Index F Fan cooling 1-14, 2-47 Fault Screen 2-13 Fault Symptom Codes (FSC) 6-4 FCC and VCCI Requirements A-9 Features 1-8 Field Replaceable Parts locations D-2 Firmware Revision 2-24 Front Panel and Media Locks 2-11 G General Drive Errors 6-2 Getting Help xvi H Help additional sources xvi Compaq authorized resellers, telephone numbers xvii Compaq website xvii technical support telephone numbers xvi Host SCSI Interface C-2 http://www.compaq.
4 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide Menus configure 2-22 drive status 2-20 library status 2-19 load/unload 2-18 maintenance 2-22 map information 2-21 security 2-22 show history 2-22 show status 2-18 MiniLibrary features 1-1 flexibility 1-2 menu structure 2-16 Modules 1-1 Storage Architecture 1-2 MiniLibrary Base Module Control Panel illustrated 2-8 MiniLibrary Base Module Front View illustrated 1-5 MiniLibrary Base Module Rear View illustrated 1-11 Modules 2-37, 2-4
Index S Safety Certifications A-6 Screens base module default 2-14 default 2-13 fault 2-13 initialization 2-13 POST 2-12 SCSI daisy-chained 2-40 data transfer rate 1-7 SCSI IDs setting 3-31 SCSI Interface Configurations 1-7 SCSI Interfaces 3-22 Second Tape Drive installing D-9 Security Menu 2-22 Selecting Control Panel Display Modes 2-15 Set Auto Clean Mode 3-39, 4-14 Set Baud Rate 3-39, 4-13 Set Data Format 4-4 Set Date 3-39, 4-8 Set Default 3-40 Set Element Base 4-7 Set Identification 3-39 Set Library Mo
6 Compaq StorageWorks TL881/TL891 Family MiniLibrary System Reference Guide U W Using CE Diagnostics 6-21 Using the Demo Submenu 6-22 Using the Tape Drives F-14 Warnings electrical shock xv rack stability xv Write Protection 2-36 Write-Enabling Cartridges F-13 Write-Protecting and WriteEnabling Cartridges F-13 www.compaq.com.