User Guide

This is the yellow on page 5–16 (seq: 108)
This is the magenta on page 5–16 (seq: 108)Red
5–16
This is the cyan on page 5–16 (seq: 108)
5–16
Company confidential. Genie User’s Guide, Edition 2, First Draft . Freeze Status: open
This is the blue on page 5–16 (seq: 108)
This is the black on page 5–16 (seq: 108)
Correct Incorrect
The lower test patterns check the color alignment; there are six patterns each
with two different primary colors. If there is misalignment between the primary
colors, the composite color will be present in one part of the circle and white
will be visible at the opposite side of the circle. Misalignment can be horizontal
or vertical, or a combination of the two.
Correct Incorrect
If either set of patterns shows an alignment problem (a third color is present or
there is misalignment in the boxes or the circles of the test image, try the
following:
1 Replace the failing cartridge and print the Print Quality Test Print again.
2 If the problem continues perform the Accuracy Calibration (see page 6–11) and
print the Print Quality Test Print again to see if there has been any improvement.
Special internal prints
Using the Print Quality Test Print