User Guide
5–18
Company confidential. Genie User’s Guide, Edition 2, First Draft . Freeze Status: open
This is the blue on page 5–18 (seq: 110)
This is the black on page 5–18 (seq: 110)
Correct Incorrect
If there is negative or positive banding in the test image, try the following:
1 Perform the Accuracy Calibration (see page 6–11) and print the Print Quality Test
Print again to see if there has been any improvement.
2 Remove the all cartridges and clean the flex contacts on the carriage and the
cartridges. Reseat the cartridges and try the test again.
3 If the error is still present, replace the cartridges and print the Print Quality Test
Print again.
Special internal prints
Using the Print Quality Test Print