Troubleshooting guide

Error messages 166
Audible Beeps: None
Possible Cause: Defective drive or cables detected.
Action:
1. Be sure all cables are connected properly and securely.
2. Be sure all drives are fully seated.
3. Replace defective cables, drive X, or both.
1784-Slot X Drive Array - Logical Drive Failure
Audible Beeps: None
Possible Cause: Defective drive or cables detected.
Action:
1. Be sure all cables are connected properly and securely.
2. Be sure all drives are fully seated.
3. Replace defective cables, drive X, or both.
1785-Slot X Drive Array not Configured...
(followed by one of the following:)
...* Run Array Configuration Utility
* No Drives Detected
* SAS Cable(s) Attached to Wrong SAS Port Connector(s) Turn system power OFF and swap SAS port connectors
to prevent data loss.
* Drive positions cannot be changed during Capacity Expansion.
* Drive positions appear to have changed. Run Array Diagnostics Utility (ADU) if previous positions are unknown.
Then turn system power OFF and move drives to their original positions.
* Configuration information indicates drive positions beyond the capability of this controller. This may be due to
drive movement from a controller that supports more drives than the current controller. To avoid data loss turn system
power OFF and reattach drives to the original controller.
* Configuration information indicates drives were configured on a controller with a newer firmware version. To
avoid data loss, reattach drives to original controller or upgrade controller firmware.
Audible Beeps: None
Possible Cause: Drive array configuration not detected.
Action:
Run ACU.
Power down the system and swap the SAS port connectors to prevent data loss.
Run ADU ("Array diagnostic software" on page 76) if previous positions are unknown. Then, power
down the system and move the drives to their original positions.
To avoid data loss, update the controller firmware to the same or later version on the original controller
("Firmware maintenance" on page 80).
1786-Slot X Drive Array Recovery Needed...
...The following drive(s) need Automatic Data Recovery (Rebuild): Port x Box y Bay(s) z
Select F1 to continue with recovery of data to drive. Select F2 to continue without recovery of data to drive.