User guide

Using LO100 43
o
On ML150 G5 servers:
i. Press the down arrow () key to scroll down to the Console Redirection option, and press the
Enter key.
ii. Verify the following settings:
Console RedirectionEnabled
Baud Rate115.2K
Terminal TypeVT100+
Flow ControlNone
Redirection after BIOS POSTOn
o On DL160 G5 servers:
i. Press the down arrow () key to scroll down to the Remote Access Configuration option, and
press the Enter key.
ii. Verify the following settings:
Remote AccessEnabled
EMS support(SPCR)Enabled
o On DL165 G5 and DL185 G5 servers:
i. Press the down arrow () key to scroll down to the Remote Access Configuration option, and
then press the Enter key.
ii. Verify the following settings:
Console RedirectionEnabled
EMS Support (SPCR)Enabled
Serial Port Mode09600 8,n,1
Flow ControlNone
Redirection After BIOS POSTAlways
Terminal TypeVT100
Sredir Memory Display DelayNo Delay
o On DL180 G5 servers:
i. Press the down arrow () key to scroll down to the Remote Access Configuration option, and
press the Enter key.
ii. Verify the following settings:
Remote AccessEnabled
EMS support(SPCR)Enabled
Terminal TypeVT100
Flow ControlNone
Redirection after BIOS POSTAlways
o On SL165z G6 servers:
i. Press the down arrow () key to scroll down to the Remote Access Configuration option, and
press the Enter key.
ii. Verify the following settings: