User guide

Using LO100 45
Terminal TypeVT100
Sredir Memory Display DelayNo Delay
I/O Device ConfigurationConfigure IO Port
Serial Port 1 Address3F8/IRQ4
o On HP ProLiant ML115 G5, ProLiant DL165 G5, and ProLiant DL185 G5 servers, verify the
following settings:
Configure Console Redirection
Console RedirectionEnabled
EMS Support (SPCR)Enabled
Flow ControlNone
Redirection After BIOS POSTAlways
Terminal TypeVT100
Sredir Memory Display DelayNo Delay
I/O Device Configuration-Configure IO Port
Serial Port 1 Address3F8/IRQ4
o On HP ProLiant DL120 G5 servers, verify the following settings:
Console Redirection
Console RedirectionEnabled
EMS supportEnabled
Baud Rate115.2K
Terminal TypeVT100
Flow ControlNone
Continue C.R. after POSTEnabled
I/O Device Configuration
Base I/O address3F8
InterruptIRQ 4
o On HP ProLiant ML150 G5 servers, verify the following settings:
Console Redirection
BIOS Serial consoleEnabled
EMC Support (SPCR)Enabled
Baud Rate115.2K
Console TypeVT100
Continue C.R. after POSTOn
I/O Device Configuration
Serial Port AEnabled
Base I/O address3F8
InterruptIRQ 4
o On HP ProLiant DL160 G5 servers, verify the following settings: