User guide
Using LO100 47
ii.
Verify the following settings:
— Console Redirection—Enabled
— Baud Rate—115.2K
— Terminal Type—VT100+
— Flow Control—None
— Redirection after BIOS POST—On
o On ML115 G5, DL165 G5, and DL185 G5 servers:
i. Press the down arrow (↓) key to scroll down to the Console Redirection option, and then press
the Enter key.
o Verify the following settings:
— Console Redirection—Enabled
— EMS Support (SPCR)—Enabled
— Serial Port Mode—09600 8,n,1
— Flow Control—None
— Redirection After BIOS POST—Always
— Terminal Type—VT100
— Sredir Memory Display Delay—No Delay
o On DL120 G5 servers:
i. Press the down arrow (↓) key to scroll down to the Console Redirection option, and then press
the Enter key.
ii. Verify the following settings:
— Console Redirection—Enabled
— EMS support—Enabled
— Baud Rate—115.2K
— Terminal Type—VT100
— Flow Control—None
— Continue C.R. after POST—Enabled
o On ML150 G5 servers:
i. Press the down arrow (↓) key to scroll down to the Remote Access Configuration option, and
then press the Enter key.
ii. Verify the following settings:
— Remote Access—Enabled
— EMS support(SPCR)—Enabled
— Serial Port Mode—115200 8,n,1
— Flow Control—None
— Console Type—VT100
— Continue C.R. after POST—Always
o On ML160 G5 servers: