User guide

Using LO100 47
ii.
Verify the following settings:
Console RedirectionEnabled
Baud Rate115.2K
Terminal TypeVT100+
Flow ControlNone
Redirection after BIOS POSTOn
o On ML115 G5, DL165 G5, and DL185 G5 servers:
i. Press the down arrow () key to scroll down to the Console Redirection option, and then press
the Enter key.
o Verify the following settings:
Console RedirectionEnabled
EMS Support (SPCR)Enabled
Serial Port Mode09600 8,n,1
Flow ControlNone
Redirection After BIOS POSTAlways
Terminal TypeVT100
Sredir Memory Display DelayNo Delay
o On DL120 G5 servers:
i. Press the down arrow () key to scroll down to the Console Redirection option, and then press
the Enter key.
ii. Verify the following settings:
Console RedirectionEnabled
EMS supportEnabled
Baud Rate115.2K
Terminal TypeVT100
Flow ControlNone
Continue C.R. after POSTEnabled
o On ML150 G5 servers:
i. Press the down arrow () key to scroll down to the Remote Access Configuration option, and
then press the Enter key.
ii. Verify the following settings:
Remote AccessEnabled
EMS support(SPCR)Enabled
Serial Port Mode115200 8,n,1
Flow ControlNone
Console TypeVT100
Continue C.R. after POSTAlways
o On ML160 G5 servers: