Administrator's Guide

EMU Type : 1
Hw Version : A
Aux Info : SVN: 2452, HM: 1.2
SHOW ENCLOSURE FAN
Syntax
SHOW ENCLOSURE FAN { ALL | <fan number> }
Description
Displays information about and current status of the specified enclosure fan.
Restrictions
The <fan number> must be 1 or 2.
Fan information is not available if fan status is Dormant (meaning not powered).
EM is only directly controlling FAN 1. The JBOD IE expanders control FAN 2 so information
on FAN 2 can only be reported if enclosure power is on AND at least one SAS IO module is
present and functioning normally.
Not all information (for example, part number and serial number) of FAN 2 are reported to
EM by the SAS module so it cannot be reported as with FAN 1.
When enclosure power is first turned on, FAN 2 status changes from ‘Dormant’ to ‘Absent
and then to actual status when this information is given to the EM.
Example
EM-78E7D1C12074> show enclosure fan all
Fan #1 information:
Status: OK
Speed: 33 percent of Maximum speed
Maximum speed: 14000
Minimum speed: 4200
Product Name: HP IDP FAN MODULE
Part Number: 999999
Spare Part Number: 620825-001
Version: 0.9
Fan #2 information:
Status: OK
Speed: 30 percent of Maximum speed
Maximum speed: 14000
Minimum speed: 0
Version: 0.9
SHOW ENCLOSURE INFO
Syntax
SHOW ENCLOSURE INFO
Description
Displays information about the enclosure and included options.
2
Restrictions
None
2. Some information, such as Enclosure Name, is user supplied, and if never programmed has a default value. The Solution
part number, serial number and name string are programmed in the factory depending on the software SKU that is
pre-installed. These numbers and strings are not customer programmable but vary by solution SKU even if the CSP is
the same type. The solution numbers, not the chassis numbers, are used for warranty obligation tracking.
162 EMU reference