Administrator's Guide

Description
Resets the server bay by momentarily removing all power. This also resets iLO and is a required
operation following firmware update of iLO.
Restrictions
This command functions only if the enclosure power is already on. Because the EM hardware
cannot determine if a blade is physically present unless enclosure power is on, the EM reports the
warning that the blade is not present if this command is used when enclosure power is off.
SET SERVER UID
Syntax
SET SERVER UID { ALL | <bay#> [{ , | - } <bay#>]} { ON | OFF }
Description
Turns on or off the Unit Identification (UID) LED on the specified server(s).
Restrictions
This command functions only if the enclosure power is already on.
4
SET SERVER BOOT
Syntax
SET SERVER BOOT { FIRST | ONCE } { NORMAL | HDD | PXE | RBSU } { ALL |
<bay#> [{ , | - } <bay#>]}
Description
Turns on or off the Unit Identification (UID) LED on the specified server(s).
Persistently stores a setting for the IPL to be passed to the specified server(s) at the next reboot.
SET SERVER BOOT FIRST sets the boot order of the blade.
SET SERVER BOOT ONCE sets the boot device to be used on the next boot of the bay(s) specified;
The RBSU option is only available for SET SERVER BOOT ONCE.
Restrictions
This setting is only valid on present blades and is cleared if the blade is removed.
This command functions only if the enclosure power is already on. Because the EM hardware
cannot determine if a blade is physically present unless enclosure power is on, the EM reports
the warning that the blade is not present if this command is used when enclosure power is
off.
SHOW SERVER NAMES
Syntax
SHOW SERVER NAMES
Description
Displays a brief description of all server blades.
Restrictions
This command functions only if the enclosure power is already on. If power is not on, the command
responds with the message: “enclosure power is off. If power is just now coming on but state
4. Because the EM hardware cannot determine if a blade is physically present unless enclosure power is on, the EM reports
the warning that the blade is not present if this command is used when enclosure power is off.
CLI reference 173