Administrator's Guide

Description
The EM sends a command to the health monitor to enable main DC power (just as if the user had
pressed the enclosure power button).
Restrictions
None
UPLOAD CONFIG
Syntax
UPLOAD CONFIG {<URL>}
Description
Uploads a script to the specified URL, which duplicates the current runtime configuration. Supported
protocols are FTP and TFTP. The URL should be formatted as: protocol://host/path/
filename. If your FTP server does not support anonymous logins, you can specify a username
and password within the URL formatted as: ftp://username:password@host/path/
filename
Restrictions
Only IPv4 is supported in EM version 1.0.
SET EM NAME
Syntax
SET EM NAME "<EM name>"
Description
Sets the user defined string reported with SHOW EM STATUS. The system responds with confirmation
of the change. The default (unset by user) EM name is ‘EM-<mac address>' where <mac-address>
is the hardware Ethernet address for the iLO port on the EMU. For example, EM-78E7D1C12074.
Restrictions
<EM name> must be 1 to 32 characters long and includes all alphanumeric, underscore (_) , and
dash (-) characters.
SET ENCLOSURE ASSET
Syntax
SET ENCLOSURE ASSET [TAG] "<asset tag>"
Description
Sets the enclosure asset tag that is stored persistently in the EM, displayed with SHOW ENCLOSURE
INFO command.
Restrictions
<asset tag> must be 1 to 32 characters long and includes all alphanumeric, underscore (_) and
dash (-) characters.
SET ENCLOSURE ID
Syntax
SET ENCLOSURE ID <id>
178 EMU reference