HP StorageWorks ESL9000 Series Pass-Through Mechanism (PTM) Installation Guide (February 2005)

Introduction
13HP StorageWorks ESL9000 Series Pass-Through Mechanism (PTM) Installation Guide
Preparing for installation
Before beginning the installation procedure:
1. Verify the packing slip for all required tools.
2. Make sure that you have the required upgrade parts and tools. One upgrade kit
is required for this procedure.
3. Make sure the library is functional by running SysTest from the Operator
control panel (refer to the HP StorageWorks ESL9000 Series Tape Library
User Guide).
4. Perform a calibration and inventory using the Operator control panel (refer to
the HP StorageWorks ESL9000 Series Tape Library User Guide).
PTM upgrade parts
Table 2 lists the parts included in the PTM upgrade kit:
Table 2: PTM upgrade parts
Part number Quantity Description
6312661 1 PTM assembly
6312026 1 Lower cabinet attachment channel
6312027 1 Upper cabinet attachment plate
6312028 2 Upper cabinet spacer plate
0685521 8 Washers .265 x 0.87 x 0.090
0615113 8 Screws 1/4C x 0.75 (black)
0615112 16 Screws 1/4C x 0.75
6310881 1 Interconnect cable
6310876 2 Queued Serial Peripheral Interface (QSPI)
terminator
6316323 1 Right side plate adapter
(For ESL9198 and
ESL9322 only)
6316341 1 PTM cable cover
0615018 6 Screws SMPC 6C x 0.312
6316342 1 Bin shelf opening cover
0685553 9 Push-in clips