HP StorageWorks ESL9000 Series Pass-Through Mechanism (PTM) Installation Guide (February 2005)

Installing a PTM
25HP StorageWorks ESL9000 Series Pass-Through Mechanism (PTM) Installation Guide
8. Attach the right library to the lower cabinet attachment channel with five bolts
(P/N 0615113) and washers (P/N 0685521). Do not fully tighten; allow the
lower cabinet attachment channel to float freely.
9. Lower the leveling feet on both libraries.
10. Using the 12 inch (30 cm) level, level both libraries appropriately while
maintaining the following:
a. The tape cartridge bin walls should be coplanar within 0.06 inch
(1.5 mm).
b. The front surfaces of the two libraries should be coplanar within 0.25
inches (6.4 mm).
c. The top surfaces of the two libraries should be coplanar within 0.06
inches (1.5 mm).
11. Tighten the lower cabinet attachment channel screws in both libraries to a
torque value of 70 in/lb.
12. Install the two spacers (P/N 6312028) and the upper cabinet attachment plate
(P/N 6312027) with seven screws and washers on each library. (See Figure 6
on page 26 or Figure 7 on page 27 depending on your model.)