HP StorageWorks Interface Manager and Command View TL Installation Guide (March 2005)
Table Of Contents
- Title
- Contents
- About this Guide
- 1: Introduction
- 2: Hardware Installation
- Preparing the Installation
- Installing the Expansion Cage in the ESL Series Library
- Installing the Fibre Channel Interface Controllers into the Expansion Cage
- Installing the Interface Manager Card into the Expansion Cage
- Connecting the Cables
- Connecting the Interface Manager Card to the Fibre Channel Interface Controllers
- Connecting the SCSI Bus Cables
- Connecting the Fibre Channel Cables
- Connecting the Interface Manager Card to the LAN
- Connecting the PC or Laptop
- Completing the Hardware Installation
- 3: Configuration and Software Installation
- 4: Troubleshooting
- A: Serial and Ethernet Pin Assignments
- B: Regulatory Compliance Notice
- Federal Communications Commissions Notice
- Harmonics Conformance (Japan)
- German Noise Declaration
- C: Electrostatic Discharge
- D: Specifications
- Index
63Interface Manager and Command View TL Installation Guide
4
Troubleshooting
LED Diagnostic Codes
Table 5: Status LED diagnostic codes
Red LED Green LED Description
On Off BIOS code failed to run.
Blinks 1x per
5 second
interval
Off Hardware POST failed. No firmware images are
loaded.
Blinks 2x per
5 second
interval
Off No CompactFlash disk or valid boot sector image
found.
Blinks 3x per
5 second
interval
Off Specified firmware image files were not found.
Neither the current nor the previous image was
found.
Blinks 4x per
5 second
interval
Off Load or execute command failed (boot code
remains at end of process). This indicates that load,
decompress, or execution failed on both the current
and previous image files.
Off Blinks 1x
per 5
second
interval
Load or execute command succeeded. Boot code
successfully loaded, decompressed, and initiated
execution of one of the image files.