HP LaserJet Enterprise, HP PageWide Enterprise - HP Security Event Logging Messaging Reference (white paper)
Chapter 3 – Basic logging 129
Message:
<device type>: IPv6 warning: Address Cache Overflow. Address: <IPv6 address>
interface=<interface>
Interface(s):
N/A
Syslog severity:
Warning
Explanation:
Configuration of IPv6 address failed.
Variables:
<device type> - see Table 2-2.
<interface> - Networking interface on the local device that was used to send the message to the
syslog server. Possible values are:
• Wired
• AP
• STA
Message:
<device type>: registered system name <system name> with WINS server <WINS server IP
address> interface=<interface>
Interface(s):
N/A
Syslog severity:
Informational
Explanation:
System name was registered with the WINS server.
Variables:
<device type> - see Table 2-2.
<system name> - System name.
<WINS server IP address> - IP address of the WINS server.
<interface> - Networking interface on the local device that was used to send the message to the
syslog server. Possible values are:
• Wired
• AP
• STA
Message:
<device type>: WINS: registration successful, inconsistency with JD database and WINS server
database. interface=<interface>
Interface(s):
N/A
Syslog severity:
Warning
Explanation:
Registration response from WINS server contained the wrong IP Address and time-to-live.
Variables:
<device type> - see Table 2-2.
<interface> - Networking interface on the local device that was used to send the message to the
syslog server. Possible values are:
• Wired
• AP
• STA
Message:
<device type>: failed to register system name <system name> with primary WINS server <WINS
server IP address> interface=<interface>
Interface(s):
N/A
Syslog severity:
Warning
Explanation:
Registration of system name with the primary WINS server failed.
Variables:
<device type> - see Table 2-2.
<system name> - System name.