HP LaserJet Enterprise, HP PageWide Enterprise - HP Security Event Logging Messaging Reference (white paper)

Chapter 2 Enhanced security event logging 8
<value> - New system time.
<old value> - Old system time.
<user> - Authenticated user who modified the system time. If an unauthenticated user modified
the system time, the user key-value pair is not contained within the message.
<client computer IP address> - IP address of the client computer that sent the system time
modification request.
Message:
<device type>: System time changed; time="<timestamp>" value="<value>" old_value="<old
value>" user="<user>" outcome=success
Interface(s):
Control panel
Syslog severity:
Informational
Explanation:
The system time was modified.
Variables:
<device type> - see Table 2-2.
<timestamp> - see Table 2-2.
<value> - New system time.
<old value> - Old system time.
<user> - Authenticated user who modified the system time. If an unauthenticated user modified
the system time, the user key-value pair is not contained within the message.
Message:
<device type>: System time changed; time="<timestamp>" value="<value>" old_value="<old
vlaue>" source_IP="<NTS IP address>" outcome=success
Interface(s):
NTP
Syslog severity:
Informational
Explanation:
The local device synchronized its system time with the Network Time Server.
Variables:
<device type> - see Table 2-2.
<timestamp> - see Table 2-2.
<value> - New system time.
<old value> - Old system time.
<NTS IP address> - IP address of the Network Time Server.
Remote control-panel
Message:
<device type>: Login; time="<timestamp>" user="<user>" source_IP="<client computer IP
address>" outcome=success
Interface(s):
EWS
Syslog severity:
Informational
Explanation:
Remote control-panel session was launched.
Variables:
<device type> - see Table 2-2.
<timestamp> - see Table 2-2.
<user> - User who launched the remote control-panel.