HP LaserJet Enterprise, HP PageWide Enterprise - HP Security Event Logging Messaging Reference (white paper)

Chapter 2 Enhanced security event logging 86
<client computer IP address> - IP address of the client computer that sent the request to delete
the device user account.
Message:
<device type>: Device User Account modified; time="<timestamp>" user="<display name
attribute>" source_IP="<client computer IP address>" outcome=success
Interface(s):
EWS
Syslog severity:
Informational
Explanation:
A device user account was modified.
Variables:
<device type> - see Table 2-2.
<timestamp> - see Table 2-2.
<display name attribute> - Display name attribute of the device user account.
<client computer IP address> - IP address of the client computer that sent the request to modify
the device user account.
Message:
<device type>: Default Permission Set for sign-in method modified; time="<timestamp>" sign-
in_method=local_device permission_set="<value>" old_value="<old value>" user="<user>"
source_IP="<client computer IP address>" outcome=success
Interface(s):
EWS, WS*
Syslog severity:
Informational
Explanation:
The default permission set for new device user accounts was modified.
Variables:
<device type> - see Table 2-2.
<timestamp> - see Table 2-2.
<value> - New default permission set. Possible values are:
Device Administrator
Device User
Possible values also include any custom permission sets that have been added.
<old value> - Old default permission set. Possible values are:
Device Administrator
Device User
Possible values also include any custom permission sets that have been added.
<user> - Authenticated user who modified the default permission set for new device user
accounts. If an unauthenticated user modified the default permission set for new device user
accounts, the user key-value pair is not contained within the message.
<client computer IP address> - IP address of the client computer that sent the request to modify
the default permission set for new device user accounts.
Default sign-in method for control panel
Message:
<device type>: Default Sign In Method for Control Panel applications modified;
time="<timestamp>" value=<value> old_value=<old value> user="<user>" source_IP="<client
computer IP address>" outcome=success
Interface(s):
EWS, WS*
Syslog severity:
Informational
Explanation:
The default sign-in method for the control panel was modified.
Variables:
<device type> - see Table 2-2.
<timestamp> - see Table 2-2.