HP StorageWorks FC1143 and FC1243 4Gb PCI-X 2.
Legal and notice information © Copyright 2006 Hewlett-Packard Development Company, L.P. © Copyright 2006 QLogic Corporation Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. The information contained herein is subject to change without notice.
Contents About this guide . . . . . . . . . . . . . . . . . . . . . . . . . . Intended audience . . . . . . . . Related documentation . . . . . . Document conventions and symbols HP technical support . . . . . . . Helpful web sites . . . . . . Subscription service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A Regulatory compliance and safety . . . . . . . . . . . . . . . . . Declaration of conformity for products marked with Laser device . . . . . . . . . . . . . . . . Laser safety warning . . . . . . . . . . . . . Certification and classification information . . Laser product label . . . . . . . . . . . . International notices and statements . . . . . . Canadian notice (avis Canadien) . . . . . European Union notice . . . . . . . . . . BSMI (Taiwan) . . . . . . . . . . . . . . Japanese notice . . . . . . . . .
Figures 1 2 3 4 5 PCI-X 2.0 connector . . . Class 1 laser product label BSMI (Taiwan) notice . . Japanese notice . . . . Korean notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FC1143 and FC1243 4Gb PCI-X 2.
Tables 1 2 3 4 5 6 7 8 9 6 Document conventions . . . . . HBA environmental specifications HBA specifications . . . . . . LED indicators activity . . . . . fibreutils commands . . . . . . FLASUTIL commands . . . . . FLASUTIL command examples . . Adapter Settings . . . . . . . Advanced Adapter Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
About this guide This guide provides information about: • Installing and configuring the FC1143 and FC1243 4Gb PCI-X 2.
CAUTION: Indicates that failure to follow directions could result in damage to equipment or data. IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints and shortcuts. HP technical support Telephone numbers for worldwide technical support are listed on the HP support web site: http://www.hp.com/support/.
Helpful web sites For other product information, see the following HP web sites: • • • • http://www.hp.com http://www.hp.com/go/storage http://www.hp.com/support/ http://www.docs.hp.com Subscription service HP strongly recommends that customers register online using the Subscriber’s choice web site: http://www.hp.com/go/e-updates.
About this guide
1 HBA features This chapter describes the features of the FC1143 single-port HBA (product number AB429A) and FC1243 dual-port HBA (product number AE369A). • Performance specifications, page 11 • Environmental specifications, page 12 • Physical specifications, page 12 Performance specifications The FC1143 and FC1243 HBAs are 4Gb PCI-X 2.0 high-performance direct memory access (DMA) bus master HBAs designed for high-end systems.
Environmental specifications Table 2 lists the HBA environmental specifications. Table 2 HBA environmental specifications Environment Minimum Maximum Operating temperature 0 °C/32 °F 55 °C/131 °F Storage temperature -20 °C/-4 °F 70 °C/158 °F Relative humidity (noncondensing) 10% 90% Storage humidity (noncondensing) 5% 95% Physical specifications Table 3 lists the HBA specifications. Table 3 HBA specifications Type Specification Bus interface 64-bit, PCI-X 2.
2 Installing the HBAs This chapter describes the procedure for installing the FC1143 and FC1243 HBAs, including: • Installation prerequisites, page 13 • Installation procedure, page 14 Refer to your host documentation for installing the HBAs. WARNING! Disconnect the host from the power source before installing the HBAs. To reduce the risk of personal injury from hot surfaces, allow the internal server or workstation components to cool before touching.
Installation procedure To install the HBA: 1. Check the motherboard and make any necessary configuration changes to accommodate the HBA. 2. Power down the peripherals, and then turn off the computer. 3. Disconnect the power cable. 4. Remove the computer cover and save the screws. 5. Locate the appropriate bus slot. The connector for the slot looks like the connector in Figure 1. Figure 1 PCI-X 2.0 connector 6. Remove the slot cover for the slot in which you will install the HBA. 7.
LED indicators Table 4 identifies and describes the activity of the LED indicators.
Installing the HBAs
3 Installing and configuring the Linux driver This chapter provides instructions for installing the Linux qla2xxx (The xxxis the kit date string) driver for an FC1143 or FC1243 HBA on an already installed Red Hat™Enterprise Linux (Red Hat EL) or SUSE® Linux Enterprise Server (SUSE SLES) system. You can obtain the software kit for the driver from the following HP web site: http://h18006.www1.hp.com/storage/saninfrastructure.html.
Using the RPM The RPM Package Manager (RPM) is a package management system that lets you easily install Linux software. Using RPM, you can install software in prebuilt bundles called RPM packages. This section is included for reference only. See this section for future separate RPM installations you may need. For example: • To install the RPM, copy the RPM package file to your system and enter the following command: # rpm -ivh package_name.
Using fibreutils This section describes how to install and use fibreutils. Use this utility to manage Fibre-attached storage. The fibreutils utility performs the following: • • • • • Gathers system information Lists information about HBAs in the target server Lists sd and sg device information Loads the latest EFI drivers Rescans for new devices Installing the fibreutils RPM HP recommends installing the fibreutils RPM found in the driver kit. It contains utilities for managing Fibre-attached storage.
Table 5 describes the fibreutils commands. Table 5 fibreutils commands Command Description adapter_info Lists useful information about HBAs in the system. Use the -h option to list other switches. hp_rescan Forces the QLA HBAs and the SCSI midlayer (scsi_mod.o) to rescan for LUNs on all adapters or a particular adapter instance. Use the -h option to list other switches. hp_system_info Gathers information on the current system and packages it into a compressed tar file.
Table 6 FLASUTIL commands Component Option Description Boot Code image /F xxxx Writes BIOS Flash. If the flash contains a valid BIOS, the existing NVRAM defaults do not change. /C xxxx Verifies the BIOS Flash of the specified HBA. /Wxxxx Copies the BIOS Flash to the QL1xROM.SAV file. /FFxxxx Writes FCode flash for the specified HBA address. /CFxxxx Verifies Fcode of the specified HBA. /FRxxxx Writes RISC code to Flash at the specified HBA address. /CRxxxx Verifies the RISC code of the specified HBA.
Table 7 shows FLASUTIL command examples. Table 7 FLASUTIL command examples Purpose Command Description Write flash in all QLogic HBAs in a system without being prompted for I/O address flasutil /f Updates the BIOS while preserving previous NVRAM defaults.
Table 8 Adapter Settings Setting Options Default Host Adapter BIOS Enabled, Disabled Disabled Frame Size 512, 1024, 2048 2048 Loop Reset Delay 0–60 seconds 5 Adapter Hard Loop ID Enabled, Disabled Disabled Hard Loop ID 0–125 0 Spin Up Delay Enabled, Disabled Disabled Connection Options 0, 1, 2 2 Fibre Channel Tape Support Enabled, Disabled Enabled Data Rate 0, 1, 2, 3 2 The following section describes the settings: • Adapter BIOS—When this setting is Disabled, the ROM BIOS on
NOTE: This option applies only to hard disks; it does not apply to tape drives and other nondisk devices. Restore Default Settings This option restores the HBA default settings. Raw NVRAM Data This option displays the HBA’s NVRAM contents in hexadecimal format. This is a troubleshooting tool; you cannot modify the data. Advanced Adapter Settings From the Configuration Settings menu in Fast!UTIL, select Advanced Adapter Settings.
• Link Down Timeout—Specifies the number of seconds the software waits for a link down to come up. The default is 30. • Operational Mode—Specifies the reduced interrupt operation (RIO) modes, if supported by the software driver. The RIO modes allow posting multiple command completions in a single interrupt. The default is 0.
Installing and configuring the Linux driver
4 Installing the Windows drivers This chapter describes how to install the Windows Storport miniport driver, including the following topics: • Prerequisites, page 27 • Installing drivers using the Smart Component, page 27 • Troubleshooting Windows, page 28 Prerequisites Perform the following tasks before you install the drivers: • Prior to installing or updating drivers, obtain the QLogic host bus adapters for x86 and x64 Linux and Windows, and x86 NetWare release notes, which are available from the H
Troubleshooting Windows This section describes how to use the Windows Event Viewer to troubleshoot Windows drivers. Using the Event Viewer The miniport drivers verify the condition of the HBA’s POST LED states. If there is a failure or a suspected failure, an error log entry appears in the Windows Event Log. Use the Event viewer to access the Event log To open the Event Viewer: 1. Click Start > Programs > Administrative Tools >Event Viewer, or right-click My Computer and select Manage. 2.
A Regulatory compliance and safety Declaration of conformity for products marked with the FCC logo, United States only This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions regarding your product, visit http://www.hp.com.
Laser product label The optional label in Figure 2 or equivalent may be located on the surface of the HP-supplied laser device. Figure 2 Class 1 laser product label International notices and statements Canadian notice (avis Canadien) This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
BSMI (Taiwan) Figure 3 BSMI (Taiwan) notice Japanese notice Figure 4 Japanese notice Korean notice Figure 5 Korean notice FC1143 and FC1243 4Gb PCI-X 2.
Electrostatic discharge To prevent damage to the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. To prevent electrostatic damage, observe the following precautions: • • • • • To avoid hand contact, transport and store products in static-safe containers.
Index A F audience, 7 B BSMI (Taiwan) regulatory compliance notice, 31 C certification and classification information, laser, 29 Class A equipment, Canadian compliance statement, 30 configuring HBAs, 22 conventions document, 7 text symbols, 7 G D declaration of conformity, 29 document conventions, 7 related documentation, 7 documentation, HP web site, 7 drivers changing parameters on Linux, 18 installing from RPM, 18 installing with Smart Component, 27 qla2xxx, 17 Storport miniport, 27 troubleshoot
K Korean regulatory compliance notice, 31 L laser international certification and classification information, 29 product label, 30 safety warning, 29 LED indicators, 15 Linux .