Intel vPro Processor Technology Setup and Configuration for the HP Z1, Z210, Z420, Z620 and Z820 Workstations
20 
6.  Review system information and make any necessary changes. 
Note: 
The MEBx password can be changed for the remote 
system in the WebGUI. 
Changing the password in the WebGUI or a remote 
console will result in two passwords. The new password, 
known as the “remote” MEBx password, will only work 
remotely with the WebGUI or remote console. The local 
MEBx password used to access the MEBx locally will not 
be changed! The user will have to keep track of both local 
and remote MEBx passwords to be able to access the 
system MEBx locally and remotely. When the MEBx 
password is initially set in AMT Setup, it serves as both the 
local and remote password. They are in sync. If the remote 
password is changed, then the passwords are out of sync. 
The remote MEBx password must also follow the criteria 
defined in the Password Guideline section for a strong 
password. 
7.  Exit. 