HP Virtual Connect for c-Class BladeSystem Version 3.00 Setup and Installation Guide for HP Integrity BL8x0c i2 Series Server Blades

Installation 42
All enclosures must have the same FC module configuration.
A single domain supports up to four c7000 enclosures.
For c7000 enclosures, install up to 16 VC-Enet modules and up to 16 VC-FC modules in the same
domain, with a maximum of 8 VC-Enet or 4 VC-FC modules per enclosure.
All VC-Enet modules must be interconnected (stacked).
All OAs and VC modules must be on the same management Ethernet network and IP subnet.
VC modules must be running Virtual Connect version 2.10 or higher.
The FC uplink configuration must be identical across all enclosures.
The OA firmware must be version 2.60 or higher.
For the most up-to-date support information, see the HP website (
http://www.hp.com/storage/spock).
Simple registration is required.
Primary Enclosure
Bay 1 Bay 2
Good
configuration?
Notes
Flex-10 Enet Flex-10 Enet Yes
Flex-10 Enet
1/10Gb-F
Enet
No
Do not mix different types of Ethernet modules in
bays 1 and 2 of the primary enclosure.
1/10Gb-F
Enet
1/10Gb-F
Enet
Yes
1/10Gb Enet 1/10Gb Enet No
Do not use HP 1/10Gb VC-Enet modules in bays 1
and 2 of the primary enclosure.
4Gb FC 4Gb FC No
Do not use Fibre Channel modules in bays 1 and 2
of the primary enclosure.
8Gb 20-Port
FC
8Gb 20-Port
FC
No
Do not use Fibre Channel modules in bays 1 and 2
of the primary enclosure.
8Gb 24-Port
FC
8Gb 24-Port
FC
No
Do not use Fibre Channel modules in bays 1 and 2
of the primary enclosure.
Bay 3 Bay 4
Good
configuration?
Notes
Flex-10 Enet Flex-10 Enet Yes
Flex-10 Enet
1/10Gb-F
Enet
No
Only install HP Flex-10 10Gb VC-Enet modules into
bays horizontally adjacent to bays containing HP
Flex-10 10Gb VC-Enet modules.
1/10Gb-F
Enet
1/10Gb-F
Enet
Yes
1/10Gb Enet 1/10Gb Enet Yes
1/10Gb-F
Enet
1/10Gb Enet Yes
1/10Gb Enet 4Gb FC No
Do not mix Ethernet and FC modules in horizontally
adjacent bays.
4Gb FC 4Gb FC Yes
Bays 3 and 4 of adjacent enclosures must also
contain FC modules.