HP Virtual Connect Version 2.12 Release Notes
Resolved issues
The following issue that existed in previous versions of Virtual Connect has been resolved in Virtual
Connect v2.12:
Resolved an issue with some server links mapped to the VC Flex-10 Ethernet module that were unable to
link up using certain enclosure and server configurations. Due to this fix, it might take an additional 30
seconds for a VC Flex-10 Ethernet module to become ready after the initial module power-up.
The following issues that existed in previous versions of Virtual Connect have been resolved in Virtual
Connect v2.10:
Resolved a potential VC GUI hang issue that occurred if an Internet browser was used and an uplink
port cable was disconnected from a VC Ethernet module.
Resolved several unexpected pop-up error messages that appeared on the VC GUI when the VC GUI
browser was open on the Profile page and a server was powered on.
Resolved an issue that the servers using FC might lose SAN connectivity for a brief period when the
primary OA module was reset.
The "connected to" information on the Fibre Channel server port information table is now updated
when manual login redistribution is performed.
After configuration changes are made (for example, changing stacking link configuration) standby
uplinks for a VC Ethernet network become active.
Resolved a memory leak in the VC Manager daemon that was triggered when both OA modules
were absent from the enclosure.
The VC GUI now prevents inline edits on the Profile page when servers are powered on.
After physically removing VC-FC modules from bays 5 and 7, administrative removal of those
modules is executed successfully when double-dense mode is enabled.
Entering CTRL-C during a CLI command execution no longer terminates the ssh sessions and logs out
the user.
Resolved an issue with triggering a memory dump when a QLogic QMH2562 8Gb FC HBA is used
to boot Integrity BL860c or BL870c server blades from a SAN and a message "Physical memory
dump FAILED with status 0xC0000001" appeared on the server console.
Resolved an issue with servers sending a port reset with QLogic QMH2462 HBAs and the multipath
driver losing device connectivity and not recovering.
Resolved issues