HP Virtual Connect Version 3.18 Release Notes

Resolved issues 11
between the enclosures and resulted in an outage. A change has been introduced in VC release 3.17
to properly deal with the configuration synchronization during a NO-COMM state.
Resolved a GUI issue where renaming the associated network on the Edit Ethernet Network screen
cleared the native property.
Resolved a GUI issue where clicking the Server Connections tab on the Ethernet Networks screen
caused a popup message to appear stating that there are no server connections to display, even when
server profiles with assigned networks existed.
Resolved a GUI issue where the Calculating Server Connections progress bar hung after clicking the
Server Connections tab on the Ethernet Networks screen.
The VC Ethernet module recovery algorithm has been optimized to recover odd-side modules and then
even-side modules (previously the algorithm conducted a full reset/recovery of all modules in parallel).
Depending on the domain configuration, this change reduces or eliminates a potential network outage
experienced during a full enclosure recovery.
Resolved a loss of FC connectivity issue when a VC 8Gb 24-Port FC Module received a multi-sequence
frame from an in-band storage management application (the application was executing on a server
within the c7000 enclosure). This resulted in a VC 8Gb 24-Port FC Module reset and loss of FC
connectivity.
Resolved an issue where the VC 8Gb 24-Port FC Module might not recover from a NO-COMM state
after an OA failover. The IP address for the FC module was not being updated correctly, which was
blocking the proper communication with the primary VC module.
Resolved an issue where VCM reported a NO-COMM state for a VC-FC module, even though the
VC-FC module was still responding to a ping command.
Resolved an issue where the VC 8Gb 24-Port FC Module firmware version information did not display
correctly on the OA rack firmware page after an OA reset. This resolution requires OA version 3.30 or
higher.
The VC recovery algorithm has been changed so that the current configuration number is validated after
a complete recovery from an OA NO-COMM state. Previously, the read of the configuration number
might have failed, and the module was scheduled unnecessarily for a full reset and recovery (the
configuration numbers were not out of sync).
Resolved an issue where the network nativelan setting cleared after adding another network.
Resolved an issue where an hpvcm_deleteManagedObjects return code error occurred when deleting
a profile.
Resolved an issue that delayed the startup time on an enclosure with eight Flex-10/FlexFabric modules.
Resolved a performance issue where adding a single network caused an update of all configured
networks.
Resolved an issue where firmware details did not display on a Firefox browser window.
Resolved an issue where FCoE login took longer than expected when changing between fabrics. When
FCoE connectivity from FlexFabric adapters is utilized with FlexFabric modules, and server connectivity
is changed between two different SAN fabrics within VCM, it can take the server up to 2 minutes to log
in to the external SAN fabric. A change in the handling of the FCoE Initialization Protocol (FIP) was
implemented to expedite the login process.
Resolved an issue where the VCM CLI command "set enet-vlan" did not return an error for the command
"set enet-vlan VlanTagControl=Tunnel SharedServerVlanId=true".