HP Virtual Connect Version 3.61 Release Notes
Issues and workarounds 6
New issues
Issue
When using IE9 to activate the VC GUI, there is no error message when executing without Flash Player.
Issue
The VC Unknown (unmanaged) module states (Operational, VC, OA, Comm) are not being displayed in a
consistent manner.
Issue
HP VC Flex-10 and FlexFabric modules may experience an extended timeout when re-establishing a Link
Aggregation Group (LAG). This issue may increase chances for encountering a ping loss, and the likelihood
of encountering a lost ping also increases with the number of the port members in the LAG that are being
recovered or reintegrated.
Issue
When one of the uplink ports X1–X4 on the FlexFabric module is not configured for FC or is configured for
Enet, but has an FC SFP inserted into the SFP cage, the "Connector Type" displayed by VCM and the
information displayed in the detailed statistics screen are not consistent.
Issue
Changing uplink ports in a SUS removes SmartLink settings on all vNets.
Issue
If the Primary VC module is still unable to acquire an IP address after all retries have been exhausted, VCM
incorrectly clears the module configuration. If VCSU is used to check the VC health state, VCSU reports that
the module is not configured.
Issue
VC 3.61 release is still exposed to the security vulnerability CVE-2010-4180. The security concern reference
can be found on the NIST website (http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2010-4180).
Issue
The Virtual Connect Manager CLI interface does not allow creation of the local user account with passwords
containing the "|" (pipe) character.
Workaround
Use the VCM GUI to create local user accounts with passwords containing the "|" (pipe) character.
General issues
Issue
While performing OA fail over events, the GUI prompt for “restoring OA credentials” is delayed longer than
expected. The GUI displays the message “Web browser unable to communicate with VCM, please close the
browser and re-connect”. The GUI might also display additional errors.
Workaround
Start a new VCM GUI session and OA credentials can be restored successfully.
Issue
The GUI fabric status is green for uplinks linked to the Ethernet switch, even though the port type is FC and
FC SFPs are installed.