Medical Archive Solutions User Guide

179
HP Medical Archive
Troubleshooting Alarms
FERR Sum of all errors reported by a network
interface port.
At 50, monitoring the situation is advised.
At 100, a minor issue investigation is
needed. At 500, the issue is considered
major.
Check that the adapter hardware
and driver are correctly installed
and configured to work with your
network routers and switches.
When the underlying problem is
resolved, use the Configuration
tab to clear the alarm. See
page 170.
FGWA FSG Device Status; indicates the general
status of the FSG service:
0=No errors
1 = Waiting for CMSs
2 = Starting
3=Shutting Down
FSG devices need to be connected to at
least one CMS to process transactions.
If the service indicates “Waiting
for CMSs”, ensure at least one
CMS is online and running
without errors.
FGWE FSG Device State; whether the device is:
0 = Offline
1=Standby
2=Online
If the device goes into “Standby”,
continue monitoring and if the
problem persists, contact HP tech-
nical support.
If the device goes into “Offline”
and there are no known server
hardware issues (server
unplugged) or a scheduled
downtime for the device, contact
HP technical support.
FOPN Open file descriptors. A measure of oper-
ating system resource use. This value
should fluctuate as files are opened and
closed.
800 is considered an unusually high
number.
This value can become large
during peak activity. If it does not
diminish during periods of slow
activity, contact HP technical
support.
Attr.
Code
Description Recommended Action