HP B-series Fabric OS 7.0.
© Copyright 2012–2013 Hewlett-Packard Development Company, L.P.
Version 7.0.2d NOTE: This software conforms to the Fibre Channel (FC) standards and accepted engineering practices and procedures. Description Fabric OS 7.0.2d is a patch release based on Fabric OS 7.0.2c. All hardware platforms and features supported in Fabric OS 7.0.1 and later are also supported in Fabric OS 7.0.2d. Fabric OS 7.0.2d contains problem resolutions for defects, including all the problem resolutions from Fabric OS 7.0.1x and 7.0.2x.
This switch does not support: ◦ Encryption/Compression on ISLs ◦ 10 Gbps speed ◦ Integrated Routing • HP SN8000B 8 Gbps 32-port Enhanced Fibre Channel Blade for the HP SN8000B 8-Slot SAN Backbone Director Switch and the HP SN8000B 4-Slot SAN Director Switch • HP SN8000B 8 Gbps 48-port Enhanced Fibre Channel Blade for the HP SN8000B 8-Slot SAN Backbone Director Switch and the HP SN8000B 4-Slot SAN Director Switch These blades support the following: ◦ Automatic VC level credit recovery to ensure a
Fabric OS 7.0.
FCIP FICON Accelerator Enhancements Fabric OS 7.0.1 and later enables ESCON and Bus/Tag printer emulation support on FCIP platforms. This feature provides near native performance for FICON Extended paths to remote ESCON or Bus and Tag printers. Enabling FICON Printer emulation requires the Advanced FICON Acceleration license. This feature is supported on the HP 1606 SAN Extension Switch and the HP DC SAN Director Multiprotocol Extension Blade. Optionally licensed software Fabric OS 7.0.
a high bandwidth FCIP tunnel and failover resiliency. Each FCIP circuit also supports four QoS classes (Class-F, High, Medium and Low Priority), each as a TCP connection. The Adaptive Rate Limiting feature provides a minimum bandwidth guarantee for each tunnel with full utilization of the available network bandwidth without impacting throughput performance under high traffic load.
Available on the HP StorageWorks DC04 SAN Director Switch and HP StorageWorks DC SAN Backbone Director Switch platforms only. • HP SN8000B ICL POD License. This license activates ICL ports on core blades of an HP SN8000B 8-Slot SAN Backbone Director Switch or an HP SN8000B 4-Slot SAN Director Switch.
Standards compliance This software conforms to the FC standards and accepted engineering practices and procedures. In certain cases, HP might add proprietary supplemental functions to those specified in the standards. For a list of standards conformance, see the HP website: http://www.hp.com. The 2408 FCoE Converged Network Switch and DC SAN Director Switch 10/24 FCoE Blade conform to the following Ethernet standards: • IEEE 802.1D, Spanning Tree Protocol (STP) • IEEE 802.
• HP StorageWorks SAN Director 32 Port 8 Gbps FC Blade (Brocade FC8-32) • HP StorageWorks SAN Director 48 Port 8 Gbps FC Blade (Brocade FC8-48) • HP StorageWorks SAN Director 64 Port 8 Gbps FC Blade (Brocade FC8-64) • HP StorageWorks SAN Director 6 Port 10 Gbps FC ISL Blade (Brocade FC10-6) • HP StorageWorks DC Switch Encryption FC Blade (Brocade FS8-18) • HP StorageWorks EVA4400 Embedded Switch Module (Brocade 5410) • Brocade 8 Gbps SAN Switch for HP BladeSystem c-Class (Brocade 5480) • HP S
Access Gateway connectivity is supported by the switches listed in this section and also by the following B-series switches: • HP StorageWorks 4/16 SAN Switch (Brocade 200e) • HP StorageWorks 4/32B SAN Switch • HP StorageWorks 4/64 SAN Switch • HP StorageWorks 4/256 SAN Director • Brocade 4 Gbps SAN Switch for HP c-Class BladeSystem (Brocade 4024) • HP StorageWorks 8/80 SAN Switch • HP StorageWorks DC SAN Backbone Director • HP StorageWorks DC04 SAN Director • HP StorageWorks 400 Multiproto
Zoning and fabric operations When configuring zoning or other fabric-wide settings in a fabric that has products operating with different versions of Fabric OS, HP recommends that you perform the configuration through an interface (such as Web Tools) to a product with the most recent version of Fabric OS. Some older versions of Fabric OS do not fully support newer hardware models, and problems may arise when configuring settings through these older products.
Table 1 Supported Fabric OS versions Model Earliest compatible version Recommended version HP StorageWorks MSA SAN Switch 2/8 3.2.1c 3.2.
Table 1 Supported Fabric OS versions (continued) Model Earliest compatible version Recommended version HP StorageWorks SAN Director 6 Port 10 Gb ISL Blade (FC10-6) 6.3.2d 7.1.1 HP StorageWorks 8/8 SAN Switch 6.3.2d 7.1.12 HP StorageWorks Encryption SAN Switch 6.3.2d 7.1.1 HP StorageWorks 1606 Extension SAN Switch (Brocade 7800) 6.3.2d HP StorageWorks 2408 FCoE Converged Network Switch (Brocade 8000) 6.3.2d 7.1.1 HP StorageWorks DC SAN Director Switch 10/24 FCoE Blade (Brocade FCOE10-24) 6.
5 HP Network Advisor 11.1.3 is the minimum version required to manage the SN3000B 16 Gbps FC Switch and the HP SN8000B 8 Gbps 32-port and 48-port Enhanced FC Blades. HP Network Advisor 12.0.0 is the minimum version required to manage the HP StoreFabric SN65000B 16Gb FC Switch. 6 DCFM 10.4.x cannot manage switches running Fabric OS 7.0.0a or later. Network Advisor 11.1.0 or later must be used to manage these switches.
The SN8000B 8 Gbps 32-port and 48-port Enhanced FC Blades and the SN3000B 16 Gbps FC Switch must run Fabric OS 7.0.1 at a minimum. Table 3 Blade Support Matrix for HP SN8000B 8-Slot SAN Backbone Director Switch and HP SN8000B 4-Slot SAN Director Switch Director blade Number of blades FC16-32 (32-port 16 Gbps FC blade) Supported with Fabric OS 7.0.
Table 4 Power supplies required for blades in DC SAN Backbone and DC04 SAN Director chassis (continued) Director blade DC SAN Backbone Director and DC04 SAN Director For the DC SAN Backbone Director or DC04 SAN Director, only two 220 VAC power supplies are required for redundancy with FX8-24 blades.2 1 2 The FC blades in this row are the only ones supported in the DC SAN Backbone Director or DC04 SAN Director with 110 VAC power supplies.
Table 5 Power Supply Requirements for HP SN8000B 8-Slot SAN Backbone Director Switch (continued) Number of Ports Director blade HP SN8000B 8-Slot SAN Backbone Director Switch FS8-18 FX8-24 Table 6 Power Supply Requirements for HP SN8000B 4-Slot SAN Director Switch Number of Ports Director blade HP SN8000B 4-Slot SAN Director Switch 96 ports max FC16-32 Two power supplies FC8-32E Any combination of 8 Gbps or 16 Gbps ports and intelligent blades FC16-32 Two power supplies FC16-48 FC8-32E FC8-48E
blade, and Brocade HBAs. Enterprise-class customers who want to manage departmental SANs can consider deploying this product. • HP Network Advisor Enterprise—An application designed for enterprise-class customers that provides unparalleled performance and scalability (24 physical or virtual fabrics, up to 9,000 switch ports).
Other recommendations Adaptive Networking/flow-based QoS prioritization • Any 8 Gbps or 4 Gbps FC platform running Fabric OS 6.2.2e or earlier version of firmware cannot form an E_Port with a 16 Gbps FC platform when Adaptive Networking QoS is enabled at both ends of the ISL. Users must disable QoS at either end of the ISL in order to successfully form an E_Port under this condition. Users can disable QoS via the portcfgQos --disable command.
Encryption Behavior for the HP StorageWorks Encryption SAN Switch and HP StorageWorks DC Switch Encryption FC Blade • For crypto tape operations, ensure that Emulex 4 Gbps PCIe FC HBA firmware/driver 2.82A4/7.2.50.007 or higher are used. Use of a lower level firmware/driver may result in hosts not being able to access their tape LUNs through a crypto target container. • If the migration to Fabric OS 7.0.0a or later does not occur from 6.4.1a, 6.4.1b, or 6.4.
• HP SKM/ESKM are supported with Multiple Nodes and Dual SKM/ESKM Key Vaults. Two-way certificate exchange is supported. See the Encryption Admin Guide for configuration information. If you are using dual SKM/ESKMs on HP StorageWorks Encryption SAN Switch/HP StorageWorks DC Switch Encryption FC Blade Encryption Group, then these SKM/ESKM appliances must be clustered. Failure to cluster results in key creation failure.
recommends that users perform sfpshow immediately after inserting the SFP and ensure SFP is seated properly before connecting the cables. • When running Fabric OS 7.0.0a or later, if any of the following features are enabled in the FCIP configuration, a downgrade operation to pre-Fabric OS 7.0.
active HP DC SAN Director 10/24 FCOE Blade results in the new standby CP not coming up. 24 • When operating in Converged Mode, tagged traffic on the native VLAN of the switch interface is processed normally. The host should be configured not to send VLAN tagged traffic on the switch’s native VLAN. • When operating in Converged Mode, tagged frames coming with a VLAN tag equal to the configured native VLAN are dropped.
• For switches having different OUI indices from the eight assigned to Brocade WWNs can differ in more than three bytes. In this case, after normal merge and a rename according to the described logic, login group names can be the same for WWNs differing only in OUIs. The merge logic would drop one of the Login Groups to satisfy the requirement to keep the Login Group Name unique in the fabric wide configuration.
FCR and Integrated Routing • With routing and dual backbone fabrics, the backbone fabric ID must be changed to keep the IDs unique. • When using FC Routing in a backbone to edge configuration with an Mi10K in the edge fabric, users may experience slow throughput for hosts attached to the Mi10K. Users may encounter this following a bounced IFL connection between the backbone and edge fabric. This slowdown can be resolved by disabling/enabling the Mi10K ports for the hosts that are impacted.
ICLs on HP StorageWorks DC SAN Backbone Director Switch /HP StorageWorks DC04 SAN Director Switch • If an HP StorageWorks DC SAN Backbone Director Switch with an 8-link ICL license is connected to an HP StorageWorks DC SAN Backbone Director Switch with a 16-link license, the HP StorageWorks DC SAN Backbone Director Switch with the 16-link license reports enc_out errors. The errors are harmless, but continue to increment.
VF incapable switch. Extra caution should be used to verify the FIDs match for all switches in the same Logical Fabric. • A switch with virtual fabrics enabled may not participate in a fabric that is using Password Database distribution or Administrative Domains. The virtual fabrics feature must be disabled prior to deploying in a fabric using these features. • There are limitations to zoning operations that can be performed from a Fabric OS 6.x switch that is in the same fabric as a Fabric OS 7.0.
HP SN8000B 4-Slot SAN Director Switch platforms while running Fabric OS 7.0.0a or later firmware • ◦ Firmware upgrade from Fabric OS 7.0 to a later release on HP 8/8 Base (0) E_Port SAN Switch, HP 8/40 Base 24-ports Enabled SAN Switch, HP 8/80 Base 48-ports Enabled SAN Switch, and the HP SN6000B 16 Gbps FC Switch. ◦ Firmware upgrade from Fabric OS 7.0.1 to a later release on the HP SN3000B 16 Gbps FC Switch. The QSFP information in the sfpshow output indicates the ID field as all zeros.
Migrating from Fabric OS 6.4.x HP StorageWorks DC SAN Backbone Director Switch/HP StorageWorks DC04 SAN Director Switch units running any Fabric OS 6.4.x release can be non-disruptively upgraded to Fabric OS 7.0.2d. Any 8 Gbps platforms (other than HP StorageWorks DC SAN Backbone Director Switch/HP StorageWorks DC04 SAN Director Switch) using a Fabric OS version earlier than Fabric OS 6.4.1a must upgrade to Fabric OS 6.4.1a or later before non-disruptively upgrading to Fabric OS 7.0.2d.
2. 3. 4. Select the link for the appropriate switch, select your product, and then select Cross operating system (BIOS, firmware, Diagnostics, etc.). Select Firmware. Select V7.x Firmware for HP StorageWorks B-series FC Switches for Fabric OS 7.0.2d. • To download the firmware, click Download. • To read the release notes, click the Release Notes tab.
forced commit command halts all active rekeying processes running in all CTCs and corrupts any LUN engaged in a rekeying operation. There is no recovery for this type of failure.
in the event of a security compromise. When disabling the encryption capabilities of the EE using the noted commands, the EE should not be hosting any CTCs. Ensure that all CTCs hosted on the HP Encryption Switch or HP Encryption Blade are either removed or moved to a different EE in the HA Cluster or EG before disabling the encryption and security capabilities. • Whenever initNode is performed, new certificates for CP and KAC (SKM/ESKM) are generated.
• SKM/ESKM dual node cluster - Auto failover considerations: In a dual node SKM/ESKM cluster configuration with the encryption switch, ensure that the two SKM/ESKM nodes are always available and online for proper key archival. If one of the SKM/ESKM nodes fails, you cannot use the configuration to create new keys. In other words, adding new targets or LUNs to the encryption path will not work until both the SKM/ESKM nodes are available.
SAN Backbone Director, HP StorageWorks DC04 SAN Director Switch, or HP SN8000B SAN Director switches. Area Comments Cascading There are special configuration considerations for environments with three or more switches (domain IDs) in a FICON fabric. Seek assistance from service support to ensure proper configuration.
Area Comments Optics When configuring interswitch links (ISLs) between a 16 Gbps platform and an 8 Gbps platform, the ISL ports must be configured for E_Port only. Serviceability FPGA version 0x1C on the HP DC SAN Director Multiprotocol Extension Blade is not supported with Fabric OS 7.0.0c. The FPGA version can be checked by issuing the bladevershow command. Serviceability zDAC may not give reliable results.
• HP 8/40 24-ports Enabled SAN Switch • HP 1606 SAN Extension Switch All platforms operating with Fabric OS 7.0.0c must be managed with HP B-series Network Advisor 11.1.2 or later. The following platforms using Fabric OS 6.4.2a may also interoperate in a fabric with switches running Fabric OS 7.0.
1 2 All ports from a 48 port card must be assigned to a logical switch with zero-based addressing configured. They must be in a logical switch other than the default switch. Supported only in a logical switch that will not have any FICON traffic. This is for FCP traffic only. Any blade not listed in Table 8 (page 37) above is not supported in a chassis that carries FICON traffic. Fabric OS 7.0.0 fixes Table 9 (page 38) lists defects closed in the Fabric OS 7.0.0 firmware release. Table 9 Fabric OS 7.0.
Table 9 Fabric OS 7.0.0 closed defects (continued) Closed fixes summary Solution On an HP StorageWorks 4/256 SAN Director running Fabric OS 6.4.0a Fixed in Fabric OS 7.0.0. or later, an unstable link triggers a continuous timeout/discard frame/unroutable frame tracing causing the CPU to be too busy to process requests. In an FCIP environment, a replication device port may fail with a panic when FCIP FastWrite is used on HP 1606 SAN Extension Switch tunnels. Fixed in Fabric OS 7.0.0.
Table 9 Fabric OS 7.0.0 closed defects (continued) Closed fixes summary Solution FICON MIB traps are missing .21 in their OID resulting in a mismatch Fixed in Fabric OS 7.0.0. between the FICON link incident MIB trap OID prefix sent from a switch with the actual OID values for these traps as per the MIB definition and MIB reference manual. Class three frame discards may occur when supportshow is executed.
Table 9 Fabric OS 7.0.0 closed defects (continued) Closed fixes summary Solution The Relay Host IP in fwmailcfg must be reconfigures after firmwaredownload. Fixed in Fabric OS 7.0.0. The speed value of 8 Gbps acquired in ifSpeed differs from the specification. Fixed in Fabric OS 7.0.0. The documentation for the fabricprincipal command needs to be updated to indicate the CLI with -p 0x02 "should not" be used rather than "cannot be used" because the command can be executed successfully.
Table 9 Fabric OS 7.0.0 closed defects (continued) Closed fixes summary Solution RX_Count is misleading/invalid on the HP 2408 FCoE switch when port 0 is included. Fixed in Fabric OS 7.0.0. Licenses may be added erroneously after a configdownload. Fixed in Fabric OS 7.0.0. CP HA Failover occurs after software verify errors. Error messages such as the following are output : 2010/11/28-09:42:02, [RAS-1004], 80, SLOT 6 | FFDC | FID 128, WARNING, STXW002, Software 'verify' error detected.
Table 9 Fabric OS 7.0.0 closed defects (continued) Closed fixes summary Solution FAN frames are not being sent by the switch to loop devices after LIP when Fixed in Fabric OS 7.0.0. fcAL.fanFrameDisable is set to 0. The HP 2408 FCoE Switch and HP DC SAN Director 10/24 FCoE Blade Workaround prior to upgrade: Disable ignore initial discovery solicitations from the CNA and go into pre-FIP mode the spanning tree or configure the when spanning tree is enabled. interface as “spanning-tree edgeport”.
Table 9 Fabric OS 7.0.0 closed defects (continued) Closed fixes summary Solution There is no functionality for querying all the IP addresses associated with the management interface of a device (both IPv4 and IPv6) over SNMP. Fixed in Fabric OS 7.0.0. Hard port faults may occur without warning messages and devices may Fixed in Fabric OS 7.0.0. lose their connectivity on the HP StorageWorks 4/32B SAN Switch running Fabric OS 5.3.0.
Table 10 Fabric OS 7.0.0a closed defects (continued) Closed fixes summary Solution Encrypted/Compressed E_Port trunk goes down following CP failover. Workaround prior to upgrade: Execute slotpoweroff /slotpoweron commands on the blade. Fixed in Fabric OS 7.0.0. Following an upgrade of a fabric switch attached to an Access Gateway switch with QoS enabled from Fabric OS 6.2.x to 6.3.x , the Access Gateway N_port is stuck in G_Port.
Table 11 Fabric OS 7.0.0b closed defects Closed fixes summary Solution In a FICON environment, connectivity problems may occur in the fabric after changing a FID assignment. The switch in the fabric reported [RTWR-1002] and [RTWR-1003] messages are output to the RAS log. Workaround prior to upgrade: Reboot or power cycle the affected switches. Secondary disk paths will not appear in the output from disk query commands. Fixed in Fabric OS 7.0.0b. Ports are fenced without errors during a supportsave.
Table 11 Fabric OS 7.0.0b closed defects (continued) Closed fixes summary Solution The portcfgshow command displays incorrect values for the "Fill Word (Current)" field. Fixed in Fabric OS 7.0.0b. TopTalker Monitor fails when the monitor is changed from Egress to Ingress. Fixed in Fabric OS 7.0.0b. Duplicate E_Port SCN error messages are seen after an HAFailover. Fixed in Fabric OS 7.0.0b.
Table 11 Fabric OS 7.0.0b closed defects (continued) Closed fixes summary Solution Configured CS_CTL values are no longer valid on write data frames (F_CTL Fixed in Fabric OS 7.0.0b. priority bit disabled) once frames are carried over FCIP links with FastWrite enabled. The CEE command reference guide is missing operands in the "show running-config" command documentation. Fixed in Fabric OS 7.0.0b. Fabric OS 7.0.0c fixes Table 12 (page 48) lists defects closed for this release. Table 12 Fabric OS 7.0.
Table 12 Fabric OS 7.0.0c closed defects (continued) Closed fixes summary Solution The WebTools Extended Fabric sub tab incorrectly displays the port speed Fixed in Fabric OS 7.0.0c. as 0 for ports configured as N16 for all 16 Gbps switches. This is a display problem only and does not affect operation of the switches.
Table 13 Fabric OS 7.0.1 closed defects (continued) Closed fixes summary Solution license, non-10 Gbps ports do require the Extended Fabric license for this operation.
Table 13 Fabric OS 7.0.1 closed defects (continued) Closed fixes summary Solution QSFP port status is not refreshed in the WebTools port admin window when Workaround prior to upgrade: Refresh, it is open at the time of insertion. Insertion/Removal of the QSFP does not or close and then re-open the Port Admin get updated and does not correctly display in an open Port Admin window. window. Fixed in Fabric OS 7.0.1. QSFP ICL ports are unexpectedly being fenced due to excessive state Fixed in Fabric OS 7.0.1.
Table 13 Fabric OS 7.0.1 closed defects (continued) Closed fixes summary Solution releases, users were required to reseat the blade to recover when backend credit was lost. On 16 Gbps platforms, configdefault may lead to an invalid port speed configuration if ports in the same group are in different logical switches. If configdefault is executed in the default switch, portcfgoctetspeedcombo settings get set to default on all logical switches. Fixed in Fabric OS 7.0.1.
Table 13 Fabric OS 7.0.1 closed defects (continued) Closed fixes summary Solution Fixed in Fabric OS 7.0.1. Switch panic or failover may occur due to an Out of Memory (OOM) condition due to MSK not freeing resources after RPL/DPL queries. Fixed in Fabric OS 7.0.1. The HP SN8000B 16 Gbps 32-port FC Blade is set to Faulty-51 after power Workaround prior to upgrade: Power cycling either of the HP SN8000B Directors. cycle the blade or the chassis. Fixed in Fabric OS 7.0.1.
Table 14 Fabric OS 7.0.1a closed defects (continued) Closed fixes summary Solution bouncing the problem port may resolve the issue. Fixed in Fabric OS 7.0.1a. Multiple IFCCs occur after warm start processing is completed on a FICON Workaround prior to upgrade: Disable Disk Controller and may cause XRC suspends. emulation. Fixed in Fabric OS 7.0.1a. Access Gateway may not appear in agshow and F_Ports cannot log in. N_Ports on Access Gateway do not receive responses after an HAreboot.
Table 14 Fabric OS 7.0.1a closed defects (continued) Closed fixes summary Solution The following issues are seen with portloopbacktest on 16 Gbps platforms: Fixed in Fabric OS 7.0.1a. • The portloopbacktest -nframes option does not work properly. • Test is skipped in slot3 and above. • Man page has incorrect default number of frames. • Mode 1 portloopbacktest fails on the HP SN8000B 16 Gbps 32-port and 48-port Fl Blades in either slot 7 or 8 of the HP SN8000B 4-Slot SAN Director Switch.
Table 15 Fabric OS 7.0.1b closed defects (continued) Closed fixes summary Solution HA Failover on the HP 4/256 SAN Director with any of the HP SAN Director Fixed in Fabric OS 7.0.1b. 8 Gbps FC Blades (16, 32, or 48-port) installed may encounter a rare race condition and a reset of the port blades may result causing temporary traffic disruption. The switch reports a duplicate WWN and may panic. Fixed in Fabric OS 7.0.1b.
Table 15 Fabric OS 7.0.1b closed defects (continued) Closed fixes summary Solution the fan should flash green when it is stopped or detected as faulty, but instead shows no light on this switch. On Fabric OS 7.0.1, supoportsave does not contain portshow fciptunnel output on for an HP Multi-protocol Router Blade. Fixed in Fabric OS 7.0.1b. The weblinker file descriptor on a CEE platform may leak when monitored Fixed in Fabric OS 7.0.1b. by Network Advisor.
Table 16 Fabric OS 7.0.2 closed defects (continued) Closed fixes summary Solution When Access Gateway fails to register the descriptor, switches may experience excessive CF usage due to generation of /var/log/ ag_desc.txt. Fixed in Fabric OS 7.0.2. CRC with good EOF is reported with certain platform/blade/port combinations. Fixed in Fabric OS 7.0.2. Enabling track changes in native mode keeps feature active when Access Fixed in Fabric OS 7.0.2. Gateway mode is enabled.
Table 16 Fabric OS 7.0.2 closed defects (continued) Closed fixes summary Solution the bandwidth is not the same as the other trunked link causing I/O disruption. The error message Unknown key name or insufficient permissions is visible periodically on the SKM log. Fixed in Fabric OS 7.0.2. During core blade replacement, a race condition occurred causing a CP panic and HA Failover. Fixed in Fabric OS 7.0.2. The perfhelp command output does not include information on the fmconfig command.
Table 16 Fabric OS 7.0.2 closed defects (continued) Closed fixes summary Solution Replication application errors occur after upgrading from Fabric OS 6.4.1_fcoe to Fabric OS 7.0.x with FCIP emulation. Fixed in Fabric OS 7.0.2. In NPIV setup, we are unable to get valid data to run perfttmon. Fixed in Fabric OS 7.0.2. The server lost access to devices when an internal CU port connected to an Fixed in Fabric OS 7.0.2. HBA turned into a G_Port.
Table 16 Fabric OS 7.0.2 closed defects (continued) Closed fixes summary Solution FCIP Emulation does not release aborted exchanges, potentially causing generated SCSI Busy status sequences if the exchange is reused within 22 seconds. Workaround prior to upgrade: Disable emulation. The HP 8/80 SAN Switch goes to a faulty status after repeated portloopback testing on Fabric OS 7.0.1 and 7.0.1a. Workaround prior to upgrade: Avoid running portloopbacktest in a loop. Fixed in Fabric OS 7.0.2.
Table 16 Fabric OS 7.0.2 closed defects (continued) Closed fixes summary Solution error occurs in the decryption path, the frame data might not be decrypted successfully. Customers can no longer import devices and run traffic without an Integrated Fixed in Fabric OS 7.0.2. Routing license on an HP B-series Multi-protocol Router Blade VEX_Port. The Integrated Routing license is required to perform this functionality starting with Fabric OS 7.0.1 and 7.0.1a. Previous releases did not require the license.
Table 16 Fabric OS 7.0.2 closed defects (continued) Closed fixes summary Solution A POST timeout occurs, taking over 60 seconds to complete on a Brocade Fixed in Fabric OS 7.0.2. 5460. On an HP SN3000B 16 Gbps Fibre Channel Switch, the portledtest -action, -npass, -port option does not give the LED pattern documented in the help page; this has no impact to functionality. Fixed in Fabric OS 7.0.2. A switch may experience a panic during firmwaredownload and CPs lose HA sync.
Table 17 Fabric OS 7.0.2a closed defects (continued) Closed fixes summary Solution Connection problems occur with third-party storage. When trying to make Fixed in Fabric OS 7.0.2a. a configuration change, the storage was unable to connect to a Brocade switch with In_Sync after switchenable and switchdisable commands were executed. The Brocade 5470 switch negotiates only to 4Gb speed. Fixed in Fabric OS 7.0.2a. A kernel panic may occur when upgrading to Fabric OS 6.4.3 and 7.0.1b or later.
Fabric OS 7.0.2b fixes Table 18 (page 65) lists the defects closed for this release. Table 18 Fabric OS 7.0.2b closed defects Closed fixes summary Solution Customers are unable to recover F_Ports in a Virtual Fabric because F_Ports Fixed in Fabric OS 7.0.2b. do not receive an Flogi accept in LS-fid96, possibly due to a missing config file in the configdb. Ports continually bounce. An FCIP Tunnel bounce occurs due to a chip reset on the HP Multiprotocol Extension Blade. Fixed in Fabric OS 7.0.2b.
Table 18 Fabric OS 7.0.2b closed defects (continued) Closed fixes summary Solution The portloopbacktest -nframes option does not work correctly. Fixed in Fabric OS 7.0.2b. CRC with good EOF errors occur on ports 1/24 and 1/74 on an HP StorageWorks DC SAN Director 64-port 8Gb FC Blade inserted in an HP SN8000B SAN Director Switch. Fixed in Fabric OS 7.0.2b.
Table 20 Fabric OS 7.0.2d closed defects (continued) Closed fixes summary Solution Boot over SAN may have an 8-second delay when the target device is not Fixed in Fabric OS 7.0.2d on the local switch. Users may be unable to query SNMP from a host when the access control list configured for SNMP contains a subnet area. Fixed in Fabric OS 7.0.2d A switch panic may occur while running supportsave with 4 Gb blades. Fixed in Fabric OS 7.0.
Table 20 Fabric OS 7.0.2d closed defects (continued) Closed fixes summary Solution ASIC entries are not being cleared upon HA processing, leading to server issues. Fixed in Fabric OS 7.0.2d In a heavily congested fabric, if an HA Failover occurs when a backend port is reporting a frame timeout, the switch falsely identifies a stuck VC and performs a link reset. Fixed in Fabric OS 7.0.