HP B-series Fabric OS 7.0.2d Release Notes (5697-2822, August 2013--includes all 7.0.x versions)

Other recommendations
Adaptive Networking/flow-based QoS prioritization
Any 8 Gbps or 4 Gbps FC platform running Fabric OS 6.2.2e or earlier version of firmware
cannot form an E_Port with a 16 Gbps FC platform when Adaptive Networking QoS is enabled
at both ends of the ISL. Users must disable QoS at either end of the ISL in order to successfully
form an E_Port under this condition.
Users can disable QoS via the portcfgQos --disable command. See the Brocade Fabric
OS Command Reference Guide for specific details of the portcfgQoS command.
When using QoS in a fabric with 4 Gbps ports or switches, Fabric OS 6.2.2 or later must be
installed on all products in order to pass QoS information. E_Ports from the DC SAN Backbone
Director or DC04 SAN Director to other switches must come up after 6.x is running on those
switches.
Access Gateway device-based mapping in ESX environments
Users who want to utilize Access Gateway’s Device-based mapping feature in the ESX environments
should refer to the Brocade Tech Note Using Brocade Access Gateway Device-Based Mapping in
VMware ESX Server Environments for best implementation practices. This document can be
downloaded from the following HP website:
http://www.hp.com/support/manuals
Under storage, select Storage networking, and then select the appropriate switch under B-series
Switches.
Access Gateway Cascading
Access Gateway cascading is not supported on the HP SN6000B 16 Gbps FC Switch or the HP
SN3000B 16 Gbps FC Switch.
Brocade HBA/Adapter Compatibility
Brocade HBA/Adapter should be using driver version 2.3.0.2 or later when attached to 16 Gbps
ports on Brocade switches.
D_Port
Fabric OS 7.0.0a or later supports the execution of D_Port tests concurrently on up to eight
ports on the switch.
There is no D_Port capability for 10 Gbps links nor for the 16 Gbps fabric at the far end of
the 10 Gbps link.
Support of D_Port is extended to R_RDY flow control mode. The R_RDY mode is useful
for active DWDM links that do not work in VC_RDY or EXT_VC_RDY flow control modes.
A new sub-option -dwdm is added to portcfgdport --enable CLI to configure D_Port
over active DWDM links. The -dwdm option will not execute the optical loopback test
while performing D_Port tests as the active DWDM links do not provide necessary support
to run optical loopback tests.
20