HP B-series Fabric OS 7.0.2d Release Notes (5697-2822, August 2013--includes all 7.0.x versions)

Table 9 Fabric OS 7.0.0 closed defects (continued)
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.0.FICON MIB traps are missing .21 in their OID resulting in a mismatch
between the FICON link incident MIB trap OID prefix sent from a switch
with the actual OID values for these traps as per the MIB definition and MIB
reference manual.
Fixed in Fabric OS 7.0.0.Class three frame discards may occur when supportshow is executed.
Customer may observe SCSI/IO errors when supportsave is executed on
specific platforms such as the HP 8/8 SAN Switch, HP 8/24 SAN Switch,
HP 8/80 SAN Switch.
Fixed in Fabric OS 7.0.0.The cfgclear description in CLI is misleading. The cfgsave command is
required after executing the cfgclear command, but that is not clear from
the description.
Fixed in Fabric OS 7.0.0.The OUI 00:24:ff is not being translated in the WWN Company ID of the
WebTools Name Server window and zoning window.
Fixed in Fabric OS 7.0.0.Multiple paths went down on customers servers due to frames being
periodically rejected by the switch.
Fixed in Fabric OS 7.0.0.The port auto disable feature is not disabling all of the E_Ports on an HP
StorageWorks DC SAN Backbone Director Switch when Loss of Synch
occurs.
Fixed in Fabric OS 7.0.0.WebTools can be launched from the Fabric Tree when using auto configured
IPv6 address but should not be.
Fixed in Fabric OS 7.0.0.On a switch with only IPv6 Address configured, users are unable to create
Certificate Signing Request (CSR) files with seccertutil command.
Fixed in Fabric OS 7.0.0.The portcfgshow command does not indicate NPIV capability for ports on
an HP DC SAN Director 10/24 FCoE Blade even though these ports do
support NPIV.
Fixed in Fabric OS 7.0.0.In WebTools, customers could be misled by switch icons if both a HP 2408
FCoE Switch and an HP 8/40 SAN Switch are present in the same
deployment.
Fixed in Fabric OS 7.0.0.In an FCIP environment, executing the supportshow clears the ftrace buffers.
Fixed in Fabric OS 7.0.0.The portname command behavior was changed in 6.3.x causing the open
portname command to no longer work.
Fixed in Fabric OS 7.0.0.WebTools does not display the IPv6 address of the switch management
port.
Fixed in Fabric OS 7.0.0.Customer may notice core files and RAS messages generated due to cald
software verify errors.
Fixed in Fabric OS 7.0.0.On an AG switch, a customer may see a type2 miss error for every FDISC
ACC which is misleading because the FDISC ACC should not be counted
as a type2 miss.
In large fabric config and large zone database, cfgenable is taking a long
time with FCIP links.
Fixed in Fabric OS 7.0.0.Users can disable the NPIV function on FCoE port of an HP 2408 FCoE
Switch.
Fixed in Fabric OS 7.0.0.The status of fwfrucfg and trackchangesset are not overwritten by
configDownload. If a customer updates a FRU config status or trackchangeset
status, then uploads the config file, followed by a configdefault, the status
will not be restored upon download of the config file.
Fixed in Fabric OS 7.0.0.There is no implementation of dynamic checking for secondary metadata.
Fixed in Fabric OS 7.0.0.It is not possible to make Enhanced TI zones on an HP 2408 FCoE Switch.
40