Table 9 Fabric OS 7.0.0 closed defects (continued)
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.0.The Relay Host IP in fwmailcfg must be reconfigures after firmwaredownload.
Fixed in Fabric OS 7.0.0.The speed value of 8 Gbps acquired in ifSpeed differs from the specification.
Fixed in Fabric OS 7.0.0.The documentation for the fabricprincipal command needs to be updated
to indicate the CLI with -p 0x02 "should not" be used rather than "cannot
be used" because the command can be executed successfully.
Fixed in Fabric OS 7.0.0.SNMP traps and related RASLOGs may not be generated as expected. For
example, SNMP-1008 messages and traps stop while a port is bouncing
every 20 minutes.
Fixed in Fabric OS 7.0.0.FCIP based acceleration sending Link Busy response to unsolicited status
frame is causing failures.
Fixed in Fabric OS 7.0.0.IPv6 named Certificate Signing Request (CSR) files may not be FTP'd to
some Windows based ftp servers because Windows servers do not accept
the ":" character in the filename which is present in IPv6 CSR filenames.
Fixed in Fabric OS 7.0.0.DCFM Real-Time and Historical graph on FCIP tunnels with multiple HP
StorageWorks B-series Multi-protocol Router Blades display only one tunnel.
Fixed in Fabric OS 7.0.0.Processes started during Telnet session do not end when session abruptly
ends; the fwmailcfg binary continues to run on the switch taking up large
amounts of CPU cycles.
Fixed in Fabric OS 7.0.0.There are some documentation errors in the Message Reference Guide for
Fabric OS6.4.1.
Fixed in Fabric OS 7.0.0.The HP 1606 SAN Extension Switch generates spurious C2-1011 raslog
errors when portloopbacktest is run.
Fixed in Fabric OS 7.0.0.There is no support for Windows LDAP with IPv6.
Fixed in Fabric OS 7.0.0.There is no support for SFP inserted/absent/faulty states to Fabric Watch
FRU monitoring catagory.
Fixed in Fabric OS 7.0.0.The compression settings displayed with the "ALL" option do not show the
active compression mode.
Workaround prior to upgrade: Reset
Ethernet port parameters using ifmodeset
command.
If Ethernet settings have been customer configured via ifmodset, they may
be reset to default values after a firmware upgrade.
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0.Resources are lost when a circuit is down for long periods of time. There
are complete FCIP Circuit and Tunnel failures after buffer pool resources
are depleted on an HP 1606 SAN Extension Switch and HP DC SAN
Director Multiprotocol Extension Blade. The tunnel is able to recover after
a reboot is performed.
Fixed in Fabric OS 7.0.0.A newly replaced device on an FL_Port does not register with name server
properly, and the initiator is unable to discover the device.
Fixed in Fabric OS 7.0.0.When writes to compact flash timeout, software reset recovery results in
access to a bad pointer triggering a kernel switch panic and results in a
switch reboot.
Workaround prior to upgrade: Use the
"portcfgislmode slot/port 1" in setting the
AN-1010 messages are logged on R_RDY ports when interoperating with
M-series switches.
E_Port in McDATA rdy mode, so that
bottleneck detection will not monitor it for
traffic congestion.
Fixed in Fabric OS 7.0.0.
Fabric OS 7.0.0 fixes 41