HP B-series Fabric OS 7.0.2d Release Notes (5697-2822, August 2013--includes all 7.0.x versions)

Table 9 Fabric OS 7.0.0 closed defects (continued)
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.0.RX_Count is misleading/invalid on the HP 2408 FCoE switch when port 0
is included.
Fixed in Fabric OS 7.0.0.Licenses may be added erroneously after a configdownload.
Workaround prior to upgrade: Ignore the
error message if seen in conjunction with
HA Failover.
CP HA Failover occurs after software verify errors. Error messages such as
the following are output : 2010/11/28-09:42:02, [RAS-1004], 80, SLOT
6 | FFDC | FID 128, WARNING, STXW002, Software 'verify' error
detected.
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0.The following error is seen when trying to copy to "running-config" on an
HP 2408 FCoE Switch:% Warning: This rule id is used for another classifier.
Workaround prior to upgrade: Manually
delete the interfering key on the host side
and login again.
A Switch with default SSH keys are not carried forward with a firmware
upgrade.
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0.Disabling a range of online VEX ports on an HP StorageWorks 400
Multi-protocol Router causes VE_Ports on DCX to become G_Ports if the
disabling occurs prior to the VE_Ports coming online.
Fixed in Fabric OS 7.0.0.The time displayed is not in synch with timezone / time changes when
timezone has been set or if time was changed with date command during
firmwarecommit.
Fixed in Fabric OS 7.0.0.The command portbeacon --enable ports on the HP StorageWorks SAN
Director 6-port 10 Gbps FC Blade does not cause the port LEDs to beacon.
However, no error or warning msg is displayed when the command
portbeacon --enable is issued.
Fixed in Fabric OS 7.0.0.In a FICON environment, FE & FF ports are disabled without any warning
message even when there is an FMS mode enable failure in the HP
StorageWorks DC04 SAN Director Switch.
Fixed in Fabric OS 7.0.0.Users are unable to configure Fabric Watch VE_Ports event notifications by
using Web Tools because the VE_Port class tab is not displayed in Web
Tools (Fabric Watch) but is displayed via CLI.
Workaround prior to upgrade: Users
should use the portstatsshow CLI to find
There is no column for discard_C3_timeout_only in porterrshow.
the c3 Rx and Tx timeout discards as the
porterrshow CLI will only show the
summation of many c3 discards.
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0.The Port Admin window indicates Online/Healthy, yet additional port Info
indicates the port is segmented.
Fixed in Fabric OS 7.0.0.In a FICON environment, FICON CUP cannot be enabled when a faulted
blade exists in the chassis.
Workaround prior to upgrade: Issue
another HA Failover to cause both CPs to
reset the web services.
After enabling https, a failover will cause the active CP to still be running
http and users will not have https services after a failover.
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0.In Access Gateway mode, devices with QoS enabled on HBA and F_Port
and N_Port would intermittently come online without the AoQ bit set.
Fixed in Fabric OS 7.0.0.Removal of the HP StorageWorks B-Series Multi-protocol Router Blade or
the HP DC SAN Director 10/24 FCoE Blade could crash the HP
StorageWorks DC SAN Backbone Director Switch during POST.
42