HP B-series Fabric OS 7.0.2d Release Notes (5697-2822, August 2013--includes all 7.0.x versions)

Table 9 Fabric OS 7.0.0 closed defects (continued)
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.0.FAN frames are not being sent by the switch to loop devices after LIP when
fcAL.fanFrameDisable is set to 0.
Workaround prior to upgrade: Disable
the spanning tree or configure the
interface as spanning-tree edgeport”.
The HP 2408 FCoE Switch and HP DC SAN Director 10/24 FCoE Blade
ignore initial discovery solicitations from the CNA and go into pre-FIP mode
when spanning tree is enabled.
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0.RASLOG message SCN-1001 severity may be misleading.
Fixed in Fabric OS 7.0.0.In a FICON environment, the HP StorageWorks DC SAN Backbone Director
Switch portstatsshow indicates a different value than RMF is reading through
the CUP using CMD= 32 (Read port statistics). Even though the counters
are updated in both cases, different values are returned for each interface.
Fixed in Fabric OS 7.0.0.There are inconsistencies between WebTools and the CLI; WebTools do
not show configured slots for expired trial slot-based licenses, but the CLI
does.
Fixed in Fabric OS 7.0.0.The SNMP: IF-MIB: ifTable excludes entries of port indices greater than the
port index of the Logical ISL. Users will not be able to get the ports that
have an index greater than port index of the Logical ISL.
Fixed in Fabric OS 7.0.0.Duplicate columns are shown in WebTools port admin advanced mode
when moving between basic and advanced mode.
Fixed in Fabric OS 7.0.0.Executing the configdownload command without disabling the LS switch
may core dump from cfgadm.
Fixed in Fabric OS 7.0.0.An IPSec enabled FCIP circuit may bounce after running a 200 ms delay
and 1% packet loss for 4 days.
Workaround prior to upgrade: Be sure to
select the save button only once.
In Access Gateway mode, in WT_Port Admin, hitting the save button multiple
times in the Edit configuration window may cause the WebLinker to crash.
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0.Running system verification multiple times could cause HP DC SAN Director
10/24 FCoE Blade to fault.
Fixed in Fabric OS 7.0.0.The supportshowcfgshow in supportsave does not match the output from a
supportshow.
Fixed in Fabric OS 7.0.0.Multiple devices lose connectivity when route is not deleted from previous
trunk master after disabling and enabling the trunk.
Fixed in Fabric OS 7.0.0.The HP StorageWorks DC SAN Backbone Director Switch management
port speed of 1000 Mbps is displayed on WebTools as 10 Mbps.
Fixed in Fabric OS 7.0.0.In a FICON environment, after IPL many FICON CHPIDs come up in Invalid
Attachment state. With DCFM actively polling the fabric and reboot of the
core HP StorageWorks DC SAN Backbone Director Switch in a large edge
fabric, HA may go out of sync.
Fixed in Fabric OS 7.0.0.With DCFM actively polling the fabric and reboot of the core HP
StorageWorks DC SAN Backbone Director Switch in a large edge fabric,
HA may go out of sync.
Fixed in Fabric OS 7.0.0.A standby CP may experiences a software "VERIFY" error causing the CPs
to lose sync.Port Auto Disable does not allow user finer granularity control
over the 5 possible events for LINK DOWN that currently trigger a port
being held offline.
Fixed in Fabric OS 7.0.0.Port Auto Disable does not allow user finer granularity control over the 5
possible events for LINK DOWN that currently trigger a port being held
offline.
Fabric OS 7.0.0 fixes 43