HP B-series Fabric OS 7.0.2d Release Notes (5697-2822, August 2013--includes all 7.0.x versions)

Table 9 Fabric OS 7.0.0 closed defects (continued)
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.0.There is no functionality for querying all the IP addresses associated with
the management interface of a device (both IPv4 and IPv6) over SNMP.
Fixed in Fabric OS 7.0.0.Hard port faults may occur without warning messages and devices may
lose their connectivity on the HP StorageWorks 4/32B SAN Switch running
Fabric OS 5.3.0.
Fixed in Fabric OS 7.0.0.There is no provision for adding a user configurable refresh to WebTools
to decrease in the polling cycle time.
Fixed in Fabric OS 7.0.0.Resets are not correctly captured in the HP StorageWorks B-series
Multi-protocol Router Blade.
Workaround prior to upgrade: Avoid
enabling the default all access with more
number of devices.
"Token freed on wrong logical port" RAS message seen when cfgsave was
executed. The cfgsave command does not complete in a fabric containing
6K devices.
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0.Superfluous warning messages (ZONE-1057) against front domain/translate
domain specified in a TI zone added to an edge fabric while the system
was failing over to the standby CP.
Fixed in Fabric OS 7.0.0.Switch config reset does not clear slot license consumed fields; license
configuration settings are not reset when the configdefault command is
executed.
Workaround prior to upgrade: Users with
no chassis role permission can use the CLI
to refer the user login information.
An unexpected error message is output when selecting the user tab for the
user role. A user with no chassis role permission will not be able to view
his own login information through WebTools.
Fixed in Fabric OS 7.0.0.
Fabric OS 7.0.0a fixes
Table 10 (page 44) lists defects closed for this release.
Table 10 Fabric OS 7.0.0a closed defects
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.0a.CRC and/or CDR-5021 errors seen on HP StorageWorks DC SAN Backbone
Director Switch, HP StorageWorks DC04 SAN Director Switch, or the HP
8/40 SAN Switch switch platforms.
Fixed in Fabric OS 7.0.0a.The HP StorageWorks DC SAN Director 64-port 8 Gbps FC Blade is set to
FAULTY 51 after removal/insertion of that blade in an HP SN8000B 4-Slot
SAN Backbone Director Switch or HP SN8000B 8-Slot SAN Backbone
Director Switch chassis with diagpost on.
Fixed in Fabric OS 7.0.0a.The FIPS firmware integrity check has gaps in coverage.
Workaround prior to upgrade: Restart
storage with VI/VT members (HP
Disabling or powering off the HP StorageWorks Encryption SAN Switch
causes the SVC nodes to go offline and into service mode.
StorageWorks Encryption SAN Switch)
online.
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0a.In a FICON environment, the active config is out of synch with Fabric OS
indicating a port is blocked after HA Failover.
Fixed in Fabric OS 7.0.0a.The HP StorageWorks Encryption SAN Switch is set to faulty, due to I/O
sizes greater than 512KB starting at LBA 0 for an encrypted LUN.
Fixed in Fabric OS 7.0.0a.In a FICON environment, CE DE is received by the host 5 seconds after B1
CCW causing a channel timeout.
44