HP B-series Fabric OS 7.0.2d Release Notes (5697-2822, August 2013--includes all 7.0.x versions)

Table 10 Fabric OS 7.0.0a closed defects (continued)
SolutionClosed fixes summary
Workaround prior to upgrade: Execute
slotpoweroff /slotpoweron commands on
the blade.
Encrypted/Compressed E_Port trunk goes down following CP failover.
Fixed in Fabric OS 7.0.0.
Workaround prior to upgrade: Disable
QoS on the fabric switch port and the port
will come up normally.
Following an upgrade of a fabric switch attached to an Access Gateway
switch with QoS enabled from Fabric OS 6.2.x to 6.3.x , the Access
Gateway N_port is stuck in G_Port.
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0a.In a FICON environment, persistent state is not set in Portcfg when the port
is blocked in the IPL file.
Workaround prior to upgrade: Toggle the
port.
D_Port is failing when more than 4-ports are initiated simultaneously.
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0a.In a FICON environment, the LPATH Reset flag is not cleared on local paths
if CUB is returned for first init IU after the reset and the path can't be
assigned as CRP.
Fixed in Fabric OS 7.0.0a.It may not be possible to restart a TPERF session until all user disabled GE
ports on the test tunnel are re-enabled. If a user disables GE_Ports on a
TPERF test tunnel while a TPERF session is in progress and the TPERF session
is terminated, TPERF may not be able to be restarted until the disabled
GE_Ports are re-enabled. When in this state and the user attempts to re-start
TPERF, they will get a message indicating that a TPERF session is already
in progress.
Fixed in Fabric OS 7.0.0a.BE credit loss detection and recovery not fully functional.
Fixed in Fabric OS 7.0.0a.In a FICON environment, local LPATHS are not cleared from CUP LPATH
db upon implicit logo for port disable.
Fixed in Fabric OS 7.0.0a.In Fabric Watch, a port is fenced during supportsave.
Workaround prior to upgrade: Disable
IPsec on FCIP tunnel.
DP panicked after modifying a metric on an FCIP circuit using a crossport
with IPSec enabled.
Fixed in Fabric OS 7.0.0.
Fixed in Fabric OS 7.0.0a.In a FICON environment, component (ms) dropping HA data update during
logical switch delete and moving of ports.
Fixed in Fabric OS 7.0.0a.HP SN8000B 4-Slot SAN Backbone Director Switch gets inundated with
[PS-5011] internal messages in the performance monitor.
Fixed in Fabric OS 7.0.0a.There is a pdmd memory increase on the standby CP of an HP SN8000B
8-Slot SAN Backbone Director Switch with max LS creation and fully
populated EX_Ports after a long period of time with I/O running
Workaround prior to upgrade: Disable
FICON Tape pipelining.
In a FICON environment, channel aborts I/O after presenting pending
Attention status.
Fixed in Fabric OS 7.0.0a.
Fixed in Fabric OS 7.0.0a.FIPS zeroization requires multiple prompting for DHCHAP clearing.
Fabric OS 7.0.0b fixes
Table 11 (page 46) lists defects closed for this release.
Fabric OS 7.0.0b fixes 45