HP B-series Fabric OS 7.0.2d Release Notes (5697-2822, August 2013--includes all 7.0.x versions)

Table 11 Fabric OS 7.0.0b closed defects
SolutionClosed fixes summary
Workaround prior to upgrade: Reboot or
power cycle the affected switches.
In a FICON environment, connectivity problems may occur in the fabric
after changing a FID assignment. The switch in the fabric reported
[RTWR-1002] and [RTWR-1003] messages are output to the RAS log.
Fixed in Fabric OS 7.0.0b.
Fixed in Fabric OS 7.0.0b.Secondary disk paths will not appear in the output from disk query
commands.
Fixed in Fabric OS 7.0.0b.Ports are fenced without errors during a supportsave.
Fixed in Fabric OS 7.0.0b.In a FICON environment, Invalid Attachment and Name Server Query
failures may occur due to delays in Name Server processing when
programming CAM entries for the ASIC.
Workaround prior to upgrade: The failure
does not occur with only a single port pair
or with FastWrite disabled.
The application commands to move data between arrays will fail when
FastWrite is enabled on an FCIP tunnel and there are two data replication
port pairs.
Fixed in Fabric OS 7.0.0b.
Workaround prior to upgrade: Stop and
disable/enable the port.
D_Port failures may occur in a high stress environment.
Fixed in Fabric OS 7.0.0b.
Fixed in Fabric OS 7.0.0b.Firmwaredownload signature verification fails for directors, allowing invalid
packages to be loaded as valid firmware.
Fixed in Fabric OS 7.0.0b.A fabricd crash may occur when utilizing D_Port functionality.
Fixed in Fabric OS 7.0.0b.Fabric Watch and Port Fencing Threshold settings erroneously apply to
D_Ports, and could cause D_Ports to become fenced.
Fixed in Fabric OS 7.0.0b.Hosts may lose access to storage after changing the FCR backbone domain
ID on an HP StorageWorks DC SAN Backbone Director Switch/ HP
StorageWorks DC04 SAN Director Switch with HP StorageWorks DC SAN
Director 64-port 8 Gbps FC Blade and HP StorageWorks SAN Director
48-port 8 Gbps FC Blade installed. Frame drops occur on the backend
ports of the blades.
Fixed in Fabric OS 7.0.0b.There is a stuck VC on the HP StorageWorks DC04 SAN Director Switch
backend ports between the Core Blade in slot 3 and the HP DC SAN
Director Multiprotocol Extension Blade in slot 7.
Fixed in Fabric OS 7.0.0b.Excessive port errors (encoding out errors) may occur on HP 8/8 or 8/24
SAN Switches ISL ports in a configuration consisting of a mix of 4 Gbps
user ports interconnected via 8 Gbps ISLs.
Fixed in Fabric OS 7.0.0b.Backend CRC errors and timeouts may occur on an HP StorageWorks DC
SAN Director 64-port 8 Gbps FC Blade in an HP SN8000B 8-Slot SAN
Backbone Director Switch or HP SN8000B 4-Slot SAN Director Switch.
Fixed in Fabric OS 7.0.0b.Ports are not auto disabled because LOSN is not recognized by
portautodisable.
Fixed in Fabric OS 7.0.0b.The track changes feature with Trackchanges setting of 1,1 is not generating
the TRCK-1003 message when a SSH session is logged out.
Fixed in Fabric OS 7.0.0b.The Name Server contains stale entries after a faulty disk is removed from
a loop attached device.
Fixed in Fabric OS 7.0.0b.After an HP DC SAN Director Multiprotocol Extension Blade is replaced
the InBand management configuration is not properly loaded on to the new
blade.
Workaround prior to upgrade: Disable
FCIP FastWrite.
An FCIP Tunnel in an FCR Backbone may lose buffer credits and go down
if FastWrite is enabled.
Fixed in Fabric OS 7.0.0b.
46