HP B-series Fabric OS 7.0.2d Release Notes (5697-2822, August 2013--includes all 7.0.x versions)

Table 11 Fabric OS 7.0.0b closed defects (continued)
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.0b.The portcfgshow command displays incorrect values for the "Fill Word
(Current)" field.
Fixed in Fabric OS 7.0.0b.TopTalker Monitor fails when the monitor is changed from Egress to Ingress.
Fixed in Fabric OS 7.0.0b.Duplicate E_Port SCN error messages are seen after an HAFailover.
Fixed in Fabric OS 7.0.0b.HP B-series Network Advisor incorrectly displays devices as initiators for
certain storage devices that may log in with an unknown FC4 type.
Fixed in Fabric OS 7.0.0b.Customers may experience intermittent CRC errors which may result in data
read failures when performing large data reads from 3rd party tape drives.
Fixed in Fabric OS 7.0.0b.Users may not be able to configure TE interface after ceeportloopbacktest.
Fixed in Fabric OS 7.0.0b.Tape jobs intermittently fail with tape pipelining enabled when utilizing a
FICON to ESCON converter.
Fixed in Fabric OS 7.0.0b.Unable to access the boot prom on a Brocade 8 Gbps SAN Switch for HP
BladeSystem c-Class when installed in a c7000 BladeSystem enclosure.
Fixed in Fabric OS 7.0.0b.When upgrading a switch in IM2/IM3 to Fabric OS 7.0 via WebTools,
the failure message references the interopmode command, but does not
provide WebTools instructions. The message should direct users to the
Interoperability tab to change the switch to Brocade Native Fabric Mode.
Fixed in Fabric OS 7.0.0b.The caution message output when executing D_Port CLI mentions "only
Brocade Branded SFPs".
Fixed in Fabric OS 7.0.0b.SOFf frame counter is not detecting SOFf frame ingress/egress when the
filter monitor is enabled.
Fixed in Fabric OS 7.0.0b.Firmware upgrade from v6.4 to Fabric OS 7.0 is blocked without sufficient
information from the error message. A more detailed error message is
needed.
Fixed in Fabric OS 7.0.0b.Config download fails on the HP SN6000B 16 Gbps FC Switch with the
following message: configDownload: Invalid Time Zone tz = (Asia/Tokyo)
Process function of configdownload failed for filter ts, lrc = -1
Fixed in Fabric OS 7.0.0b.In a FICON environment, XRC processing is not correctly reporting RRS
Sequence Validation failures (via 0x0F52 command reject) in all cases.
This can lead to LOGREC entries with Command Rejects with reason code
0x0F61 against a 0xFF command resulting in XRC suspensions.
Fixed in Fabric OS 7.0.0b.HP SN8000B 4-Slot SAN Director Switch panics during systemverification
when systemverification is run repeatedly.
Fixed in Fabric OS 7.0.0b.All clear text and encrypted LUNs are reporting: LUN state unavailable.
Fixed in Fabric OS 7.0.0b.When NPIV is disabled on FCoE ports prior to upgrading to Fabric OS
7.0.0x, NPIV cannot be enabled on those FCoE ports.
Fixed in Fabric OS 7.0.0b.Although the encryption engine may receive a successful response when a
logout is issued by the initiator, the encryption engine does not correctly
handle Logout Extended Link with the initiator, and the initiator continues
to successfully issue read commands to the encryption engine.
Fixed in Fabric OS 7.0.0b.In a FICON environment, an FSPF error message appears as soon as the
CEC POR is started, but does not appear in the errdumpall output.
Fixed in Fabric OS 7.0.0b.Certain traffic patterns may cause backend CRC errors on HP StorageWorks
DC SAN Director 64-port 8 Gbps FC Blades when installed in Slots 3 and
9 of an HP StorageWorks DC SAN Backbone Director Switch.
Fixed in Fabric OS 7.0.0b.With the CS_CTL bit set properly, data is not traversing the correct FCIP
H/M/L QoS connection.
Fabric OS 7.0.0b fixes 47