Table 14 Fabric OS 7.0.1a closed defects (continued)
SolutionClosed fixes summary
bouncing the problem port may resolve
the issue.
Fixed in Fabric OS 7.0.1a.
Workaround prior to upgrade: Disable
emulation.
Multiple IFCCs occur after warm start processing is completed on a FICON
Disk Controller and may cause XRC suspends.
Fixed in Fabric OS 7.0.1a.
Workaround prior to upgrade:Perform a
switch reboot (not HAreboot).
Access Gateway may not appear in agshow and F_Ports cannot log in.
N_Ports on Access Gateway do not receive responses after an HAreboot.
Fixed in Fabric OS 7.0.1a.
Fixed in Fabric OS 7.0.1a.There is a slight FCIP tunnel performance drop when running small I/O
throughput with Fabric OS 7.x.
Workaround prior to upgrade:Perform
power cycle on the switch or blade slot.
A switch panic may occur after detection of an SRAM parity error on an
HP StorageWorks 400 Multi-protocol Router and HP StorageWorks B-series
Multi-protocol Router Blade.
Fixed in Fabric OS 7.0.1a.
Fixed in Fabric OS 7.0.1a.In Fabric OS 7.0.x and later, the switch name server rejected RFT_IDs
requests on NPIV ports with a Logical Busy reason code and the host
is unable to see the device if it does not retry the request.
Fixed in Fabric OS 7.0.1a.On 16 Gbps platforms, ports that are not connected go into a disabled
state after an HAfailover.
Workaround prior to upgrade:Connect
through the console and then start CMSH
Performing a Telnet or SSH to the HP 2408 FCoE Switch and then starting
CMSH may cause a switch reboot.
or connect using Telnet/SSH from the
same subnet.
Fixed in Fabric OS 7.0.1a.
Fixed in Fabric OS 7.0.1a.CRC errors with good EOF occur on the following blade/port combinations:
HP StorageWorks DC SAN Backbone Director Switch with HP
StorageWorks SAN Director 48-port 8 Gbps FC Blade in slot 3,
3/55<->5/18
HP StorageWorks DC04 SAN Director Switch with HP StorageWorks
SAN Director 48-port 8 Gbps FC Blade in slot 2, 3/56 <->2/40
HP StorageWorks DC SAN Backbone Director Switch with HP
StorageWorks DC SAN Director 64-port 8 Gbps FC Blade in slot 12,
5/151<->12/33
HP StorageWorks DC04 SAN Director Switch with HP StorageWorks
SAN Director 16-port 8 Gbps FC Blade in slot 1, slot 2
HP StorageWorks DC SAN Backbone Director Switch with HP
StorageWorks DC SAN Director 64-port 8 Gbps FC Blade in slot 2,
8/80 <->2/155
Fixed in Fabric OS 7.0.1a.Switch F_Port trunk area configuration may be lost when upgrading to
Fabric OS 6.4.x.
Fixed in Fabric OS 7.0.1a.When HA Failover occurs on a fabric switch, F_Port trunks may lose
connectivity.
Fixed in Fabric OS 7.0.1a.Link timeouts may occur on internal ports during a
slotpoweroff/slotpoweron test being performed on multiple port
blades. When a credit loss poll detection occurs at the same time, port
blades go down and a RASlog error C3-1012 and C3-1014 occurs.
54