HP B-series Fabric OS 7.0.2d Release Notes (5697-2822, August 2013--includes all 7.0.x versions)

Table 15 Fabric OS 7.0.1b closed defects (continued)
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.1b.HA Failover on the HP 4/256 SAN Director with any of the HP SAN Director
8 Gbps FC Blades (16, 32, or 48-port) installed may encounter a rare race
condition and a reset of the port blades may result causing temporary traffic
disruption.
Fixed in Fabric OS 7.0.1b.The switch reports a duplicate WWN and may panic.
Fixed in Fabric OS 7.0.1b.SERDES tuning was enhanced to address CRC with good EOF errors on
the HP DC SAN Backbone Director with the 48-port 8 Gbps FC Blade and
the 64-port 8 Gbps FC Blade, and on the HP DC04 SAN Director Switch
with the 48-port 8 Gbps FC Blade and the 16-port 8 Gbps FC Blade.
Fixed in Fabric OS 7.0.1b.The server may lose access to devices when the internal CU port connected
to an HBA turned into a G_Port.
Fixed in Fabric OS 7.0.1b.FICON emulation does not properly handle IU pacing updates. Fabric
aborts occur and the system may go down due to slow receipt of frames
from the HP 400 Multi-protocol Router.
Fixed in Fabric OS 7.0.1b.A failure occurs when running tests portledtest -npass 10 and
portloopbacktest -lb_mode 1.
Fixed in Fabric OS 7.0.1b.SNMP no longer functions on a switch and fails to restart after it crashes
and generates a core file twice.
Fixed in Fabric OS 7.0.1b.Multi-volume tape jobs fail over an HP 400 Multi-protocol Router/HP
Multi-protocol Router Blade emulation.
Fixed in Fabric OS 7.0.1b.On an HP 8/80 SAN Switch, when a portloopbacktest is repeatedly
performed using a script on Fabric OS 7.0.1 or 7.0.1, the test may initially
pass, but the switch changes to a faulty status.
Fixed in Fabric OS 7.0.1b.After upgrading the Brocade 8 Gbps SAN Switch for HP BladeSystem
c-Class to Fabric OS 6.4.0 and later, the Onboard Administrator incorrectly
reports the management IP address as 0.0.3.0.
Fixed in Fabric OS 7.0.1b.FICON Emulation incorrectly generates an LBY and an abort sequence
(IFCC) is detected on the host console after an unsolicited status was received
from an Alias Device Address.
Fixed in Fabric OS 7.0.1b.Performance is slightly lower on a compressed FCIP tunnel in Fabric OS
7.0.1a in comparison to Fabric OS 6.4.2a. The delay is from TCP Initiator
and can be as much as 1.4 milliseconds when the TCP packet is less than
1/2 of the TCP MSS.
Workaround prior to upgrade: Start a
multiple CCW tape read/write job (more
After a tunnel bounce or slot/chassis reboot, the performance of certain
FICON Tape Write jobs is limited.
than 1 CCW in the read/write chain).
This automatically corrects the peer side
pool state information.
Fixed in Fabric OS 7.0.1b.
Fixed in Fabric OS 7.0.1b.The man pages for islshow and fdmishow need updating because they
are not consistent with the code.
Fixed in Fabric OS 7.0.1b.In Fabric OS 7.0.1a, issuing the statsclear command incorrectly returns
an error and outputs the message Invalid slot number 0 detected
in chassis system. Please use --slot option or setslot
command to provide a valid slot.
Fixed in Fabric OS 7.0.1b.A large number of C2-5825 CRC with good EOF errors are seen on an HP
DC SAN Backbone Director when a 64-port 8 Gbps FC Blade is installed
in slot 1.
Fixed in Fabric OS 7.0.1b.The LED behavior of the fan FRU does not match what is documented in the
hardware manual on an HP SN6000B 16 Gbps FC Switch. The LED on
56