HP B-series Fabric OS 7.0.2d Release Notes (5697-2822, August 2013--includes all 7.0.x versions)

Table 16 Fabric OS 7.0.2 closed defects (continued)
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.2.When Access Gateway fails to register the descriptor, switches may
experience excessive CF usage due to generation of /var/log/
ag_desc.txt.
Fixed in Fabric OS 7.0.2.CRC with good EOF is reported with certain platform/blade/port
combinations.
Fixed in Fabric OS 7.0.2.Enabling track changes in native mode keeps feature active when Access
Gateway mode is enabled. However, the CLI no longer functions in Access
Gateway mode.
Fixed in Fabric OS 7.0.2.If a number of rwmonitors are created for a particular port using the
perfaddrwmonitor command and these are deleted, then, in some
situations, the perfcfgrestore does not restore all of the monitors
previously created.
Fixed in Fabric OS 7.0.2.A software verify error is detected when portstatsshow was executed
with an invalid index and the -f option. This may result in a switch panic.
Fixed in Fabric OS 7.0.2.On switches running Fabric OS versions earlier than Fabric OS 7.0.2, the
security vulnerability check may fail, triggering an increase in memory and
CPU usage and leading to a Denial of Service condition with the Httpd
server.
Fixed in Fabric OS 7.0.2.The ifmodeset is set to the default, causing management ports to go down
after a Fabric OS code upgrade.
Fixed in Fabric OS 7.0.2.When trying to replicatate SNMP settings from one switch to another using
Network Advisor, AAA LDAP settings are also getting replaced.
Fixed in Fabric OS 7.0.2.F_Port trunk area configuration may be lost in switches when upgrading to
Fabric OS 6.4.x.
Fixed in Fabric OS 7.0.2.Counters are not getting initialized causing traffic to be reported on a port
with no traffic when configuring the End-to-End monitor.
Workaround prior to upgrade: Toggle the
port (disable/enable) to correct the issue.
Data stops flowing on fabrics wiht ETIZoning when switching zoning
enforcement from Hard-Port to Hard-Wwn and vice versa.
Fixed in Fabric OS 7.0.2.
Fixed in Fabric OS 7.0.2.Configdownload fails with a segmentation fault, when it is done to a
chassis having motd set with a config file having no motd set.
Fixed in Fabric OS 7.0.2.F_Port trunk loses connectivity after an HA Failover.
Fixed in Fabric OS 7.0.2.Multiple IFCCs occur after warm start processing completed on a FICON
Disk Controller. The number of IFCCs can cause XRC suspends.
Fixed in Fabric OS 7.0.2.While running diagnostics, an unsuccessful read at low level or bad
SFP/media may trigger a switch panic.
Fixed in Fabric OS 7.0.2.Fabric Watch messages report TX and RX performance values above 100%.
Fixed in Fabric OS 7.0.2.After an HA Reboot on a Brocade 5460 switch, internal ports go
offline/online with warm recovery.
Workaround prior to upgrade: Disable
emulation.
Users may experience corruption on SRDF replication with FCIP FastWrite
enabled.
Fixed in Fabric OS 7.0.2.
Fixed in Fabric OS 7.0.2.When fabric rebuild and merge events occur close together, the domain
gets out of sync with the configuration database. New devices will have
incorrect PIDs and will be inaccessible to other devices.
Fixed in Fabric OS 7.0.2.On 8 Gbps switch platforms running Fabric OS 7.x, when there are multiple
trunk groups in the same domain, a trunked link may be abandoned when
58