Table 16 Fabric OS 7.0.2 closed defects (continued)
SolutionClosed fixes summary
error occurs in the decryption path, the frame data might not be decrypted
successfully.
Fixed in Fabric OS 7.0.2.Customers can no longer import devices and run traffic without an Integrated
Routing license on an HP B-series Multi-protocol Router Blade VEX_Port. The
Integrated Routing license is required to perform this functionality starting
with Fabric OS 7.0.1 and 7.0.1a. Previous releases did not require the
license.
Fixed in Fabric OS 7.0.2.A large number of CRCs with good EOF errors occur on an HP DC SAN
Director when an HP 64-port 8 Gbps FC Blade is installed in slots 1,3, and
9.
Workaround prior to upgrade: Perform
an HA Failover.
PortPerfShow showing bandwidth utilization is being reported as 0.
Fixed in Fabric OS 7.0.2.
Fixed in Fabric OS 7.0.2.Modifications were made to SNMP MIBs : swCpuAction, swMemAction,
FA-MIB, and swFCPortSpeed.
Fixed in Fabric OS 7.0.2.The HP SN3000B 16 Gbps Fibre Channel Switch LED behavior for fan FRU
LED data does not match the hardware manual description. The LED shows
no light instead of flashing to indicate there is a fan problem.
Fixed in Fabric OS 7.0.2.In Fabric OS 7.0.1, supportsave does not contain portshow
fciptunnel output on an HP B-series Multi-protocol Router Blade.
Fixed in Fabric OS 7.0.2.Customer may experience asserts and weblinker terminations and restarts.
This is non disruptive to traffic.
Fixed in Fabric OS 7.0.2.On select configurations, customers are able to query the switch via HTTP
for information without authenticating with a username/password.
Fixed in Fabric OS 7.0.2.Disk replication fails when the response to RNID is discarded.
Fixed in Fabric OS 7.0.2.A race condition may occur during bootup between fabric watch and the
environment monitor modules, causing fabric watch to get stale information
and falsely report that a power supply is not present.
Workaround prior to upgrade: Perform
an HA Failover to resume traffic.
With In Order Delivery set, using port mirror to view traffic causes the switch
traffic to stop.
Fixed in Fabric OS 7.0.2.
Fixed in Fabric OS 7.0.2.Discard C3 counter field shows a higher count than the C3 Timeout RX and
TX fields in the porterrshow.
Fixed in Fabric OS 7.0.2.On Encryption platforms, unable to re-key LUNs after moving the LUN from
clear text to an encrypted state. This is caused by a high frequency of Test
Unit Ready (TUR), etc. commands, resulting in the Database getting out of
synch.
Fixed in Fabric OS 7.0.2.When a user enters the number of flows value, which is equal to 32 in
platforms where the maximum flows allowed is 32, the output of perfttmon
--show does not match the expected results.
Fixed in Fabric OS 7.0.2.Internal ports encountered errors on a Brocade 5460 switch during
firmwaredownload and power on.
Fixed in Fabric OS 7.0.2.There are inaccurate performance counters when configuring a user monitor
with multiple offsets and each offset has multiple values in the value list.
Workaround prior to upgrade: Reseat the
blades.
On 8 Gbps platforms, frame drops are encountered when credit loss is
detected.
Fixed in Fabric OS 7.0.2.