HP B-series Fabric OS 7.0.2d Release Notes (5697-2822, August 2013--includes all 7.0.x versions)

Table 16 Fabric OS 7.0.2 closed defects (continued)
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.2.A POST timeout occurs, taking over 60 seconds to complete on a Brocade
5460.
Fixed in Fabric OS 7.0.2.On an HP SN3000B 16 Gbps Fibre Channel Switch, the portledtest
-action, -npass, -port option does not give the LED pattern
documented in the help page; this has no impact to functionality.
Fixed in Fabric OS 7.0.2.A switch may experience a panic during firmwaredownload and CPs
lose HA sync. This may occur while managing the switch via SMI-A and
the SMI-A sends management server requests MS_GPORT_NG command
during the code upgrade.
Fixed in Fabric OS 7.0.2.An update was made to the severity level of the raslog FSSM-1004 message
upgraded from Info to Warning.
Fixed in Fabric OS 7.0.2.The perfresourceshow installed command output is inconsistent
with documentation. The terms "Top Talker F-Port mode" and "Filter monitor"
need to be updated to "Top Talker Port Mode" and "Frame Monitor" to be
consistent with the documentation.
Fixed in Fabric OS 7.0.2.When there is a D_Port and an E_Port connecting two switches and the
E_Port is disabled due to authentication (or any other non-fabric reason),
the D_Port becomes part of the fabric and join the switches.
Workaround prior to upgrade: Disable
emulation.
A DP panic on an HP 1606 SAN Extension Switch may occur leaving
behind only an FFDC file. This panic is very rare and may cause disruption.
Fixed in Fabric OS 7.0.2.
Workaround prior to upgrade: Disable
FICON printer emulation.
FICON IFCCs for extended emulated printer sequences during Unit Check
Processing. This occurs on 3203 and 3800 Model 1 printers.
Fixed in Fabric OS 7.0.2.
Fixed in Fabric OS 7.0.2.CRC with Good EOF errors are detected on the HP DC SAN Director on
the 5/139 link when an HP 32-port 8 Gbps FC Blade is installed in slot 3
and on the 5/100 link when HP 24-port 8 Gbps FC Blade is installed in
slot 4. These errors may impact traffic.
Workaround prior to upgrade: Execute
the portdisable CLI command on ports
without a POD license.
On the HP 8/8 SAN Switch, the HP 8/24 SAN Switch, and the HP 8/80
SAN Switch, a hardware tool shows the SerDes transmitter is on and
generating signals on ports without a POD license causing an EMI issue.
Fixed in Fabric OS 7.0.2.
Fixed in Fabric OS 7.0.2.There are multiple instances of CRC with Good EOF errors across numerous
8 Gbps card types. New functionality was added to enable, disable, reset,
and display the current status of the SerDes automated tuning process. It is
disabled by default.
Fabric OS 7.0.2a fixes
Table 17 (page 63) lists the defects closed for this release.
Table 17 Fabric OS 7.0.2a closed defects
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.2a.CRC with good EOF detected on multiple ICL ports between an HP DC SAN
Backbone Director and an HP DC04 SAN Director.
Fixed in Fabric OS 7.0.2a.Unexpected NTP behavior and RASLOG error messages TS-1002. This
occurs when changing NTP source using the tsclockserver command.
Fixed in Fabric OS 7.0.2a.The fmmonitor --clear command does not properly clear the count
value.
Fabric OS 7.0.2a fixes 63