Table 18 Fabric OS 7.0.2b closed defects (continued)
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.2b.The portloopbacktest -nframes option does not work correctly.
Fixed in Fabric OS 7.0.2b.CRC with good EOF errors occur on ports 1/24 and 1/74 on an HP
StorageWorks DC SAN Director 64-port 8Gb FC Blade inserted in an HP
SN8000B SAN Director Switch.
Fixed in Fabric OS 7.0.2b.CRC with good EOF errors occur on port 5/45 with an HP StorageWorks
SAN Director 32-port 8Gb FC Blade inserted in slot 3 of an HP
StorageWorks 4/256 SAN Director.
Fixed in Fabric OS 7.0.2b.Firmwaredownload on an HP SN3000B 16Gb FC Switch is not blocked
and loading Fabric OS versions earlier than 7.0.1 cause the switch to be
inoperable.
Fixed in Fabric OS 7.0.2b.Output from the turboramtest on an HP SN8000B SAN Director Switch
and an HP SN6000B 16Gb FC Switch is inconsistent.
Fixed in Fabric OS 7.0.2b.Users are unable to delete user accounts that were created using AD settings
in a Virtual Fabric environment.
Fixed in Fabric OS 7.0.2b.LUN discovery fails due to a busy HP StorageWorks DC Switch Encryption
FC Blade processor.
Fabric OS 7.0.2c fixes
Table 19 (page 66) lists the defects closed for this release.
Table 19 Fabric OS 7.0.2c closed defects
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.2c.An HP StorageWorks DC SAN Director 64-port 8 Gb FC Blade running in
slot 1 of an HP SN8000B SAN Backbone Director or an HP DC SAN
Backbone Director experienced a blade fault due to excessive CRC with
good EOF errors.
Workaround prior to upgrade: Use
SNMPv1/v2. SNMPv3 with users having
Unable to query any OID from a read/write SNMPv3 user.
Read Only (RO) permission are able to
discover the switch, perform CAL/HTTP
queries and SNMP get operations.
Fixed in Fabric OS 7.0.2c.
Fixed in Fabric OS 7.0.2c.A 16 Gb switch panic may occur during a switch install, slot power cycle
test.
Fabric OS 7.0.2d fixes
Table 20 (page 66) lists the defects closed for this release.
Table 20 Fabric OS 7.0.2d closed defects
SolutionClosed fixes summary
Workaround prior to upgrade: Rebuild
the fabric manually by bouncing the
After a Fabric OS upgrade, multiple ports report Not ready for F or
L ports, due to an inconsistency in domain count and E_Port count during
HA Failover.
E_Port or perform a switch
disable/enable.
Fixed in Fabric OS 7.0.2d
Fixed in Fabric OS 7.0.2dThe spinfab diagnostic test does not attain the expected throughput of 3.2G
for Long Distance E_Port using 16 Gb LWL 10 km SFP.