HP B-series Fabric OS 7.0.2d Release Notes (5697-2822, August 2013--includes all 7.0.x versions)

Table 20 Fabric OS 7.0.2d closed defects (continued)
SolutionClosed fixes summary
Fixed in Fabric OS 7.0.2dBoot over SAN may have an 8-second delay when the target device is not
on the local switch.
Fixed in Fabric OS 7.0.2dUsers may be unable to query SNMP from a host when the access control
list configured for SNMP contains a subnet area.
Fixed in Fabric OS 7.0.2dA switch panic may occur while running supportsave with 4 Gb blades.
Fixed in Fabric OS 7.0.2dSome hosts that make FC-4 type based Name Server queries are unable
to establish paths to storage.
Workaround prior to upgrade: Avoid
managing an AG switch with Network
The HP B-series 8 Gb BladeSystem SAN Switches running in AG mode and
managed by Network Advisor exhibit an snmpd crash and switch reboot.
Advisor or have all ports connected to
either N_Port or F_Port or have AG in auto
policy disabled state.
Fixed in Fabric OS 7.0.2d
Workaround prior to upgrade: Perform a
slotpoweroff/slotpoweron or
reboot the switch to clear the condition.
After a power cycle, the HP 64-port 8Gb FC Blade installed incorrectly in
a HP SN8000B SAN Director Switch faults during POST.
Fixed in Fabric OS 7.0.2d
Workaround prior to upgrade: Reboot the
HP Encryption Switch or HP Encryption
FC Blade.
Polling container stats every 30 seconds may cause free memory to decrease
on an HP Encryption Switch blade processor.
Fixed in Fabric OS 7.0.2d
Fixed in Fabric OS 7.0.2dThe thconfig command does not properly monitor a port that has an SFP
swapped from 8 Gb to 16 Gb.
Workaround prior to upgrade: Check the
console port and make sure the settings
are correct.
The console print may hang and may stop other processes from completing.
Fixed in Fabric OS 7.0.2d
Workaround prior to upgrade: Reboot the
HP Encryption Switch or HP Encryption
FC Blade.
Network Advisor experiences an out of memory error when obtaining or
polling for encrypted LUN level information from two encryption groups
that each have 4,000 defined LUNs.
Fixed in Fabric OS 7.0.2d
Fixed in Fabric OS 7.0.2dValues from serdes auto/manual tuning session are lost after power off/on
blade or cold reboot of a switch.
Workaround prior to upgrade: Disable
the system card feature, issue cryptocfg
Authentication for crypto operations on an HP Encryption Switch or HP
Encryption FC Blade fails. When this occurs, the HP Encryption Switch or
HP Encryption FC Blade function as an ordinary FC switch or blade when
-- set -systemcard disable from
the encryption group leader.
they are powered up, and the use of the encryption engine is denied as a
result.
Fixed in Fabric OS 7.0.2d
Fixed in Fabric OS 7.0.2dContinuous FSS-1001 messages are seen after a firmware upgrade from
Fabric OS 6.4.2a to Fabric OS 6.4.3c, due to inconsistent Access Gateway
State Synchronization.
Fixed in Fabric OS 7.0.2dContinuous polling from Network Advisor causes CLI commands to fail on
the HP Encryption Switch with the error message Operation failed:
Encryption Switch/Encryption blade is not present or
up.
Fixed in Fabric OS 7.0.2dThe tunnel on an HP 1606 Extension Switch enters DwnPend state after a
configuration change is made. An IPC error is reported during subsequent
attempts to delete the tunnel.
Fabric OS 7.0.2a fixes 67