Data Center Fabric Manager Professional Plus User Manual - Supporting DCFM 10.3.x (53-1001356-01, October 2009)

DCFM Professional Plus User Manual 491
53-1001356-01
Chapter
16
Virtual Fabrics
In this chapter
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 491
Virtual Fabric requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 492
Configuring Virtual Fabrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494
Overview
NOTE
Virtual Fabrics requires that you have at least one Virtual Fabrics-enabled physical chassis running
Fabric OS 6.2.0 or later in your SAN.
Virtual Fabrics enables you to divide one physical chassis into multiple logical switches that can be
managed by separate administrators. Logical switches consist of one or more ports that act as a
single FC switch. You can interconnect logical switches to create a logical fabric.
The following lists the benefits of using the Management application to manage Virtual Fabrics:
Enables you to view your entire SAN (both physical and virtual) at a glance.
Enables you to easily determine which devices in your SAN are logical switches. Logical
switches are shown with a Virtual Fabric icon ( ).
Enables you to manage a logical switch the same as a physical switch, so that fewer physical
chassis are required for Management application deployment.
Enables you to use a logical switch for discovery and eliminate the requirement for one
physical chassis for each fabric.
Enables you to manage multiple Virtual Fabric-capable physical chassis from the same
interface.
Enables you to provide logical isolation of data, control, and management paths at the port
level.
Before using the Management application to manage Virtual Fabrics, you should familiarize
yourself with Virtual Fabrics concepts, as described in the Fabric OS Administrator’s Guide.