Quick Configuration Guide for A7000 dl 8xT1/E1 Wide Module 2005-04
2 www.procurve.com 5991-2118
PPP Diagram (Multilink Optional)
The ProCurve Secure Router may be initially accessed and managed via a console session.
Refer to Initiate a Console Session for console session instructions. Initiating a Telnet session
requires using a hub and two Ethernet cables (one for the PC and one for the unit). Refer to
Configure Telnet Access on page 10 to configure Telnet session settings.
1. Connect a VT100 terminal (or PC with VT100 emulation software) to the ProCurve Secure
Router Console port using the serial cable supplied with your router.
2. Configure the COM port with the following parameters:
Data Rate: 9600
Data Bits: 8
Parity Bits: None
Stop Bits: 1
Flow Control: None
3. Open a VT100 terminal session. (Please refer to the appropriate VT100 terminal software
documentation for detailed instructions.)
4. Press the <Enter> key.
5. Enter enable at the > prompt.
6. Enter the password when prompted or press <Enter> if you have not yet set a password.
7. You are now at the # prompt. At the # prompt, enter config terminal to enter the Global
Configuration mode.
Network Diagrams (continued)
Configure the Unit
Initiate a Console Session
T1/E1
2 to 8 T1s/E1s
T1/E1
T1/E1
PPP
(Multilink Optional)
Network IP: 10.10.20.0 /24
Network IP: 10.10.10.0 Network IP: 10.10.30.0
LAN IP:10.10.10.1 /24
LAN IP:10.10.30.1 /24
PPP1
ML PPP Signaling
68.168.72.1 /24
eth 0/1
LAN IP:
10.10.20.7 /24
68.168.72.2 /24
68.168.72.3 /24
1
2