The default port configuration for the module is:
Ports Enabled: Yes
Mode:
Gigabit-SX and Gigabit-LX Transceivers — 1000FDx (1000 Mbps, Full
Duplex)
Gigabit Stacking Transceiver — Auto (auto negotiates flow control if
flow control is enabled for the port)
Trunk (port trunking): None
Switch Mesh: Not a member
Broadcast Limit: 0 (no broadcast limiting)
Flow Control: Disabled
Spanning Tree: Disabled
IGMP: Disabled
Traffic Filters: None (the switch performs its filtering and forwarding
only according to standard address table operation)
If necessary, configure the port(s) in the module by using the switch console
or the web browser interface. For more information, see the Management and
Configuration Guide shipped with the switch, and the online Help provided
in the console and web browser interface.
If the default port configuration listed above is acceptable for your network,
then skip this process.