Installation Guide for fl Modules 2007-02
ProCurve Switch fl Modules
To perform a controlled shutdown on a management or fabric module, and
cause the redundant module to take over, enter the following command:
ProCurve 8100fl# halt <slot>
You can also perform a controlled shutdown on a management or fabric
module and cause the redundant module to take over, by entering the
following command:
ProCurve 8100fl# power down <slot>
Note To display a list of the slot numbers of all installed modules, type ? after the
command; for example, halt ? or power down ?.
Configuration Changes to Management Module
In normal operation, whenever you make configuration changes to the
primary management module, the changes are copied to the redundant
management module’s configuration file. In this way, if the primary
management module fails, the redundant module has all the configuration
information necessary to take over as the primary management module.
7