Installation Guide for fl Modules 2007-02

ProCurve Switch fl Modules
Installing Modules
Module Port Type/
Transceiver
Cable Type Length Limits
1-Port 10-GbE 10-Gbe LR 9/125 μm (core-cladding) diameter, 1310 nm, 10 kilometers
Interface Module low metal content, single-mode fiber optic (single-mode cable)
(J8733A) cables fitted with SC connectors. The cables
must comply with the ITU-T G.651 and ISO/
IEC 793-2 Type A1b or A1a standards.
X2 10GbE Modules 10-GbE SR Multimode fiber-optic cable designed for
(J8736A/J8737A) Gigabit Ethernet: 62.5/125 μm (core/
cladding) diameter or 50/125 μm, 850 nm, low
metal content, complying with the ITU-T
G.652 and ISO/IEC 793-2 Type B1 standards.
62.5 μm cable:
160 Mhz*km = 2-26 meters
200 Mhz*km = 2-33 meters
50 μm cable:
400 Mhz*km = 2-66 meters
500 Mhz*km = 2-82 meters
2000 Mhz*km = 2-300
meters
10-GbE LR 9/125 μm (core/cladding) diameter, 1480 nm,
low metal content, single mode fiber-optic
cables, complying with the ITU-T G.652 and
ISO/IEC 793-2 Type B1 standards.
single-mode cable: 2-10
kilometers
10-GbE ER 9/125 μm (core/cladding) diameter, 1550 nm,
low metal content, single mode fiber-optic
cables, complying with the ITU-T G.652 and
ISO/IEC 793-2 Type B1 standards.
single-mode cable: 2-30
kilometers (40 kilometers, on
an engineered fiber optic link
that meets standards in the
specification).
OMC CX4 Fiber
(Optical Media
Converter) for
CX4 transceiver
12 fiber 50/125 μm (core/cladding) diameter,
multimode Fiber ribbon cable. 12 fiber 62.5/
125 μm (core/cladding) diameter, multimode
Fiber ribbon cable is also supported.
1-300 meters
Note: Conditioning patch cord cables are not supported on 10-GbE speeds.
19