Verifying Cable Connections
For Switch fl interface modules, when you connect a network cable from an
active network device to the switch, the LED for the switch port should light
on as described in Table 2 and Table 3.
Management and Switch Fabric Modules LEDs
The ProCurve Switch fl Redundant Management and Switch Fabric Modules
have an Active LED (on top) and a Status LED (on bottom). The LED states
described in Table 2 are common to both types of module.
Table 2. Management and Switch Fabric Module LEDs.
LED Color State Meaning
Active Green
Green
n/a
Flashing
Solid
Off
Negotiating active/backup module(s) during
bootup sequence.
Module is active - normal.
Module is in back up mode.
Status n/a
Green
Green
Yellow/Orange
Off
Flashing
Solid
Flashing
No power to the module.
Module is booting up and downloading
operating software.
Module is in service - normal.
Self-test failure.
Interface Modules LEDs
The ProCurve Switch fl Interface Modules have the LEDs described in
Table 3—a pair of Activity and Link LEDs for each port, and a Status LED at
the bottom of each module. Note that the meaning of the per-port Activity and
Link LEDs may differ according to module.
Table 3. Interface Module LEDs
LED Color State Meaning
1-Port 10GB LR Module (J8733A)
Activity Green
Green
Flashing
Solid
Transmitting data.
Link is up, no data is being transferred.
Off Flashing When no connector is plugged into the port,
the LED will flash approximately once every
four seconds. This on/off cycle is a safety
feature known as Auto Laser Shutdown.
20