Brocade Fabric OS v6.4.3f Release Notes v1.0

Close with Code Change in Fabric OS v6.4.1a
Fabric OS v6.4.3f Release Notes v1.0 Page 115 of 149
Defect ID: DEFECT000323250
Technical Severity: Medium
Summary: Blade fault observed during heavy tape IO stress for DataFort compatible tapes.
Symptom: DataFort compatible tapes under heavy stress tape I/O jobs may lead to faulty Brocade
encryption blade or Brocade encryption switch.
Feature: Data Security
Function: Tape Encryption
Probability: Low
Found in Release: FOS6.3.2
Where Else Fixed: FOS6.4.1 a
Defect ID: DEFECT000323352
Technical Severity: Medium
Summary: "Web Tools attributes" parameters in configure are inconsistent
Symptom: Web Tools attributes appear in configupload, but not in configshow. The changes made to
the Web Tools attributes are not updated when the configuration file is modified and
downloaded back to the switch.
Feature: Mgmt Embedded - HTTP
Function: Other
Probability: Medium
Found in Release: FOS6.4.1
Service Request ID: 460053
Where Else Fixed: FOS6.4.1 a
Defect ID: DEFECT000323771
Technical Severity: Medium
Summary: Superping needs to determine exact route for each echo frame sent out when stuck VC
occurs on one of the outgoing ISLs
Symptom: Superping is not correctly reporting ISL path
Feature: Fabric Infrastructure
Function: FC PING
Probability: Low
Found in Release: FOS6.4.1
Where Else Fixed: FOS6.4.1 a
Defect ID: DEFECT000324307
Technical Severity: Medium
Summary: portcmd --ping fails with timeout after portcmd --traceroute command is cancelled.
Symptom: When running a traceroute command over a GE port on a 7800 or FX8-24, if the traceroute
command is cancelled with a ctrl+C from the command line, additional ping and traceroute
commands may timeout over the GE ports.
Feature: FCIP
Function: Other
Probability: High
Found in Release: FOS6.4.0
Where Else Fixed: FOS6.4.1 a