Brocade Fabric OS v6.4.3f Release Notes v1.0

Close with Code Change in Fabric OS v6.4.0b
Fabric OS v6.4.3f Release Notes v1.0 Page 138 of 149
Defect ID: DEFECT000298268
Technical Severity: Medium
Summary: I Series tape I/O stops with tape pipelining enabled
Symptom: Tape I/O with I Series server is not possible with tape pipelining enabled.
Workaround: Disable / do not enable tape pipelining.
Feature: FCIP
Function: FCIP I/O
Probability: Medium
Found in Release: FOS6.4.0
Defect ID: DEFECT000298400
Technical Severity: Medium
Summary: DCFM encryption support is unable to import large-sized encryption certificates
Symptom: When importing certificates that contain both the text and Base64 encoded portion of a
cert, the import will fail although DCFM encryption support does not report that it fails and
reports a success.
Feature: Data Security
Function: Infrastructure
Probability: Medium
Found in Release: FOS6.4.0
Defect ID: DEFECT000300066
Technical Severity: Medium
Summary: Data Security, EE in a DCX type chassis can fail to properly accomodate CTC upon EG re-
creation
Symptom: Containers created before EG is deleted do not show up in the fabric post EG re-creation
with chassis hosting FS8-18 blades.
Workaround: slotpoweroff/slotpower on of FS8-18 blade for CTCs to be hosted after EG re-creation.
Feature: Data Security
Function: Infrastructure
Probability: Low
Found in Release: FOS6.4.0
Defect ID: DEFECT000300754
Technical Severity: Medium
Summary: In large configurations, applying TI Zone failover disabled is causing FCP traffic over VEX to
throttle back
Symptom: Applying new TI Zone with failover disabled, FCIP performance (throughput) gets impacted.
Feature: FCIP
Function: FCIP I/O
Probability: Medium
Found in Release: FOS6.4.0