Brocade Fabric OS v6.4.3f Release Notes v1.0

Fabric OS v6.4.3f Release Notes v1.0 Page 141 of 149
Closed with Code Change in Fabric OS v6.4.0a - GA June 4, 2010
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change
as of June 4, 2010 in Fabric OS v6.4.0a.
Defect ID: DEFECT000271043
Technical Severity: High
Summary: As a result of firmwaredownload, systemverifcation test, or blade insertion, occasionally
blade FCoE10-24 may turn faulty 21
Symptom: Slotshow indicates that FCoE10-24 is found to be in a faulty state
Workaround: slotpoweroff/on the FCoE10-24 to clear the faulty state
Feature: CEE-Infrastructure
Function: ANVIL DRIVER
Probability: Medium
Found in Release: FOS6.4.0
Defect ID: DEFECT000290749
Technical Severity: High
Summary: FICON: FRU events are not generated on the operator's console for removal or insertion
Symptom: No FRU event notification at the operator's console
Feature: FICON
Function: Ficud
Probability: Medium
Found in Release: FOS6.4.0
Defect ID: DEFECT000296886
Technical Severity: High
Summary: Rare corner case of Lossless being disabled after several downgrade and upgrade
scenarios.
Symptom: A DCX logical switch with port based routing, IOD (In-Order Delivery), DLS, and LosslessDLS
enabled running Fabric OS v6.3.0b is updated to v6.4.0, Lossless gets disabled.
Workaround: Re-enable Lossless / IOD on logical switches that were previously enabled.
Feature: 8G Platform Services
Function: Routing
Probability: Low
Found in Release: FOS6.4.0
Defect ID: DEFECT000297733
Technical Severity: High
Summary: With FMS enabled, after moving all ICL and 254 FC ports into a logical switch with zero
based addressing, port 1/0 (area 00) is incorrectly disabled
Symptom: Port 0 with area 0x00 is disabled
Workaround:
Feature: 8G Platform Services
Function: FOS Kernel Drivers
Probability: Medium
Found in Release: FOS6.4.0