Brocade Fabric OS v6.4.3f Release Notes v1.0

Closed with Code Change in Fabric OS v6.4.3f
Fabric OS v6.4.3f Release Notes v1.0 Page 38 of 149
Defect ID:
DEFECT000479046
Technical Severity:
Critical
Probability:
Low
Product:
FOS
Technology:
FICON
Reported In Release:
FOS6.4.3
Technology Area:
FICON emulation
Closed In Release(s):
FOS6.4.3f(Fixed)
Symptom:
Customer observed frequent suspends in XRC emulation environment.
Condition:
When there is immediate command retry, XRC Emulation may not correctly handle Immediate Retry
Status.
Defect ID:
DEFECT000480765
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Other
Reported In Release:
FOS7.2.0
Technology Area:
Other
Closed In Release(s):
FOS6.4.3f(Fixed)
Symptom:
“Application Blocked by Security Settings” is displayed and fails to launch EZ Manager
Condition:
This issue will be seen only with older JRE updates (40 and below).
Workaround:
Use latest JRE
Defect ID:
DEFECT000481199
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Management
Reported In Release:
FOS7.2.0
Technology Area:
Web Tools
Closed In Release(s):
FOS6.4.3f(Fixed)
Symptom:
With JRE 1.7.0 update 45, users will see a warning message when WebTools is launched through
HTTPS and will not be able to launch WebTools from Network Advisor with prior to v12.1.4
Network advisor revisions
Condition:
Web Tools will be blocked when it is launched through a version of Network Advisor prior to 12.1.4
on a system running JRE 1.7u45
Web Tools will encounter error messages when it is launched directly through HTTPs on a system
running JRE 1.7u45
Workaround:
Launch Web Tools through Network Advisor running version 12.1.4 or higher
Recovery:
JRE must be downgraded to 1.7u25
Defect ID:
DEFECT000483593
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS6.4.2
Technology Area:
Frame Monitoring
Closed In Release(s):
FOS6.4.3f(Fixed)
Symptom:
After running fmconfig --show, Switch panics in psd and reboots .
Condition:
This may occur after upgrading the switch from FOS v6.3.x (with Filter Monitor installed) to v6.4.x
and then running the CLI command fmconfig --show
Workaround:
Remove filter monitor before upgrading the switch from v6.3.x to v6.4.x
Recovery:
Reboot the switch